Diamond microelectrodes for use in biological environments

被引:81
作者
Park, J
Show, Y
Quaiserova, V
Galligan, JJ [1 ]
Fink, GD
Swain, GM
机构
[1] Michigan State Univ, Dept Pharmacol & Toxicol, E Lansing, MI 48824 USA
[2] Michigan State Univ, Dept Chem, E Lansing, MI 48824 USA
基金
美国国家卫生研究院;
关键词
diamond microelectrodes; chronoamperometry; sympathetic nervous system; hypertension;
D O I
10.1016/j.jelechem.2005.04.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The response sensitivity, precision and stability of a diamond microelectrode for the measurement of catecholamines is reported on and compared with a carbon fiber microelectrode. The comparison was made (i) before and after exposure of the bare microelectrode to the laboratory atmosphere and to biological tissue, and (ii) during the in vitro measurement of norepinephrine (NE)-release from a test animal's mesenteric artery. The surface-sensitive redox system, Fe(CN)(6)(-3/-4), was also used to probe the electrode response. The diamond microelectrode exhibited a low, stable and pH-independent background current over a wide potential range; good sensitivity and response reproducibility for NE; and resistance to deactivation and fouling during exposure to the laboratory atmosphere and biological tissue. In contrast, the carbon fiber microelectrode exhibited a pH-dependent background current response with evidence for electroactive surface carbon-oxygen functional groups, and deactivated irreversibly during laboratory air exposure and contact with tissue. The same diamond electrode properties that are responsible for the deactivation and fouling resistance (e.g., the non-polar, H-terminated surface with no extended pi electron system) are also responsible for the more sluggish catecholamine electrode reaction kinetics (e.g., absence of molecular adsorption on the hydrogen-terminated sp(3) -bonded carbon surface). In addition, the bare diamond microelectrode provided excellent response characteristics during the in vitro measurement of NE-release from the mesenteric artery of a laboratory test animal. The results confirm that this new microelectrode is useful for sensitive, reproducible and stable electroanalytical measurements in complex biological environments. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 68
页数:13
相关论文
共 58 条
  • [1] ADAMS RN, 1976, ANAL CHEM, V48, P1126, DOI 10.1021/ac50007a045
  • [2] FAST-SCAN VOLTAMMETRY OF BIOGENIC-AMINES
    BAUR, JE
    KRISTENSEN, EW
    MAY, LJ
    WIEDEMANN, DJ
    WIGHTMAN, RM
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (13) : 1268 - 1272
  • [3] Contribution of alpha-adrenoceptors to depolarization and contraction evoked by continuous asynchronous sympathetic nerve activity in rat tail artery
    Brock, JA
    McLachlan, EM
    Rayner, SE
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 1997, 120 (08) : 1513 - 1521
  • [4] Spontaneous release of large packets of noradrenaline from sympathetic nerve terminals in rat mesenteric arteries in vitro
    Brock, JA
    Dunn, WR
    Boyd, NSF
    Wong, DKY
    [J]. BRITISH JOURNAL OF PHARMACOLOGY, 2000, 131 (08) : 1507 - 1511
  • [5] Microelectrodes for the measurement of catecholamines in biological systems
    Cahill, PS
    Walker, QD
    Finnegan, JM
    Mickelson, GE
    Travis, ER
    Wightman, RM
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (18) : 3180 - 3186
  • [6] NAFION-COATED CARBON-FIBER ELECTRODES FOR NEUROCHEMICAL STUDIES IN BRAIN-TISSUE
    CAPELLA, P
    GHASEMZADEH, B
    MITCHELL, K
    ADAMS, RN
    [J]. ELECTROANALYSIS, 1990, 2 (03) : 175 - 182
  • [7] ELECTRON-TRANSFER KINETICS AT MODIFIED CARBON ELECTRODE SURFACES - THE ROLE OF SPECIFIC SURFACE SITES
    CHEN, PH
    FRYLING, MA
    MCCREERY, RL
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (18) : 3115 - 3122
  • [8] Control of electron transfer kinetics at glassy carbon electrodes by specific surface modification
    Chen, PH
    McCreery, RL
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (22) : 3958 - 3965
  • [9] Structural characterization, electrochemical reactivity, and response stability of hydrogenated glassy carbon electrodes
    Chen, QY
    Swain, GM
    [J]. LANGMUIR, 1998, 14 (24) : 7017 - 7026
  • [10] DELAY IN VESICLE FUSION REVEALED BY ELECTROCHEMICAL MONITORING OF SINGLE SECRETORY EVENTS IN ADRENAL CHROMAFFIN CELLS
    CHOW, RH
    VONRUDEN, L
    NEHER, E
    [J]. NATURE, 1992, 356 (6364) : 60 - 63