Digital Versus Conventional Full-Arch Implant Impressions: A Prospective Study on 16 Edentulous Maxillae

被引:94
|
作者
Chochlidakis, Konstantinos [1 ]
Papaspyridakos, Panos [1 ,2 ]
Tsigarida, Alexandra [3 ]
Romeo, Davide [1 ,4 ]
Chen, Yo-wei [2 ]
Natto, Zuhair [5 ,6 ]
Ercoli, Carlo [1 ]
机构
[1] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, 625 Elmwood Ave, Rochester, NY 14620 USA
[2] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
[3] Univ Rochester, Eastman Inst Oral Hlth, Dept Periodont, Rochester, NY 14620 USA
[4] Univ Vita Salute San Raffaele, San Raffaele Hosp, Adv Oral Surg Unit, Milan, Italy
[5] King Abdulaziz Univ, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[6] Tufts Univ, Sch Dent Med, Dept Periodontol, Boston, MA 02111 USA
关键词
digital implant scan; accuracy; full-arch; fixed complete denture; ACCURACY; REHABILITATION; TECHNOLOGY; PROSTHESES; WORKFLOW; SURGERY;
D O I
10.1111/jopr.13162
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A prospective clinical study to compare for the first time the accuracy of digital and conventional maxillary implant impressions for completely edentulous patients. Materials and Methods Sixteen patients received maxillary implant supported fixed complete dentures. After the verification of the conventional final casts, the casts were scanned with a desktop (extraoral) scanner. Intraoral full-arch digital scans were also obtained with scan bodies and STL files. Extraoral and intraoral scans were superimposed and analyzed with reverse engineering software. The primary outcome measure was the assessment of accuracy between scans of the verified conventional casts and digital full-arch impressions. The secondary outcome was the effect of the implant number on the 3D accuracy of impressions with Spearman's rank correlation coefficient. Results The 3D deviations between virtual casts from intraoral full-arch digital scans and digitized final stone casts generated from conventional implant impressions were found to be 162 +/- 77 mu m. In the 4-implant group, 5-implant group, and 6-implant group the 3D deviations were found to be 139 +/- 56 mu m, 146 +/- 90 mu m, and 185 +/- 81 mu m, respectively. There was a positive correlation between increased implant number and 3D-deviations, but there was no statistically significant difference (p = 0.191). Conclusions The 3D accuracy of full-arch digital implant scans lies within previously reported clinically acceptable threshold. Full-arch digital scans and a complete digital workflow in the fabrication of maxillary fixed complete dentures may be clinically feasible.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [41] The accuracy of conventional versus digital (intraoral scanner or photogrammetry) impression techniques in full-arch implant-supported prostheses: a systematic review
    Joensahakij, Nitchakul
    Serichetaphongse, Pravej
    Chengprapakorn, Wareeratn
    EVIDENCE-BASED DENTISTRY, 2024, 25 (04) : 216 - 217
  • [42] Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation
    Pesce, Paolo
    Pera, Francesco
    Setti, Paolo
    Menini, Maria
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (02) : 171 - 175
  • [43] The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study
    Schlenz, Maximiliane Amelie
    Klaus, Katharina
    Schmidt, Alexander
    Wostmann, Bernd
    Mersmann, Marco
    Ruf, Sabine
    Bock, Niko Christian
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (01) : 273 - 283
  • [44] Accuracy of Conventional and Digital Methods of Obtaining Full-Arch Dental Impression (In Vitro Study)
    Husein, Hassan A.
    Morad, Mhd. Luai
    Kanout, Shaza
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [45] Digital Jaw Relation Record of Edentulous Patients in the CAD-CAM Workflow of the Implant-Supported Full-Arch Prosthesis
    Ragazzini, Nicola
    Baldissara, Paolo
    Monaco, Carlo
    Ciocca, Leonardo
    JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (01) : 57 - 62
  • [46] Evaluation of Intraoral Full-Arch Scan versus Conventional Preliminary Impression
    Janosi, Kinga Maria
    Cerghizan, Diana
    Martha, Krisztina Ildiko
    Elekes, Eva
    Szakacs, Brigitta
    Elekes, Zoltan
    Kovacs, Alpar
    Szasz, Andrea
    Muresan, Izabella
    Hantoiu, Liana Georgiana
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (17)
  • [47] Digital design and manufacture of a stackable implant surgical guide for immediate loading in completely edentulous full-arch cases: a dental technique
    Abdelaziz, Medhat Sameh
    Tella, Eman Abd El Sattar Abd El Megid
    QUINTESSENCE INTERNATIONAL, 2023, 54 (09): : 750 - 755
  • [48] Management of Biotechnical Complications Associated with a Full-Arch Implant Restoration Using Digital and Conventional Workflows: A Clinical Report
    Joshi, Niranjan
    Piermatti, Jack
    Nahon, Max
    Balshi, Thomas
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (05): : 483 - 487
  • [49] Immediate implant placement in fresh sockets versus implant placement in healed bone for full-arch fixed prostheses with conventional loading
    Altintas, N. Y.
    Taskesen, F.
    Bagis, B.
    Baltacioglu, E.
    Cezairli, B.
    Senel, F. C.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (02) : 226 - 231
  • [50] Satisfaction and quality of life with palatal positioned implants in severely atrophic maxillae versus conventional implants supporting fixed full-arch prostheses
    Candel-Marti, Eugenia
    Penarrocha-Oltra, David
    Penarrocha-Diago, Maria
    Penarrocha-Diago, Miguel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2015, 20 (06): : E751 - E756