Digital Versus Conventional Full-Arch Implant Impressions: A Prospective Study on 16 Edentulous Maxillae

被引:94
|
作者
Chochlidakis, Konstantinos [1 ]
Papaspyridakos, Panos [1 ,2 ]
Tsigarida, Alexandra [3 ]
Romeo, Davide [1 ,4 ]
Chen, Yo-wei [2 ]
Natto, Zuhair [5 ,6 ]
Ercoli, Carlo [1 ]
机构
[1] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, 625 Elmwood Ave, Rochester, NY 14620 USA
[2] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
[3] Univ Rochester, Eastman Inst Oral Hlth, Dept Periodont, Rochester, NY 14620 USA
[4] Univ Vita Salute San Raffaele, San Raffaele Hosp, Adv Oral Surg Unit, Milan, Italy
[5] King Abdulaziz Univ, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[6] Tufts Univ, Sch Dent Med, Dept Periodontol, Boston, MA 02111 USA
关键词
digital implant scan; accuracy; full-arch; fixed complete denture; ACCURACY; REHABILITATION; TECHNOLOGY; PROSTHESES; WORKFLOW; SURGERY;
D O I
10.1111/jopr.13162
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A prospective clinical study to compare for the first time the accuracy of digital and conventional maxillary implant impressions for completely edentulous patients. Materials and Methods Sixteen patients received maxillary implant supported fixed complete dentures. After the verification of the conventional final casts, the casts were scanned with a desktop (extraoral) scanner. Intraoral full-arch digital scans were also obtained with scan bodies and STL files. Extraoral and intraoral scans were superimposed and analyzed with reverse engineering software. The primary outcome measure was the assessment of accuracy between scans of the verified conventional casts and digital full-arch impressions. The secondary outcome was the effect of the implant number on the 3D accuracy of impressions with Spearman's rank correlation coefficient. Results The 3D deviations between virtual casts from intraoral full-arch digital scans and digitized final stone casts generated from conventional implant impressions were found to be 162 +/- 77 mu m. In the 4-implant group, 5-implant group, and 6-implant group the 3D deviations were found to be 139 +/- 56 mu m, 146 +/- 90 mu m, and 185 +/- 81 mu m, respectively. There was a positive correlation between increased implant number and 3D-deviations, but there was no statistically significant difference (p = 0.191). Conclusions The 3D accuracy of full-arch digital implant scans lies within previously reported clinically acceptable threshold. Full-arch digital scans and a complete digital workflow in the fabrication of maxillary fixed complete dentures may be clinically feasible.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [31] Accuracy of full-arch digital implant impressions taken using intraoral scanners and related variables: A systematic review
    Zhang, Yi-Jie
    Shi, Jun-Yu
    Qian, Shu-Jiao
    Qiao, Shi-Chong
    Lai, Hong-Chang
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (02) : 157 - 179
  • [32] Comparison of Three-Dimensional Accuracy of Digital and Conventional Implant Impressions: Effect of Interimplant Distance in an Edentulous Arch
    Tan, Ming Yi
    Yee, Sophia Hui Xin
    Wong, Keng Mun
    Tan, Ying Han
    Tan, Keson Beng Choon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (02) : 366 - 380
  • [33] The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid–based in vitro study
    Maximiliane Amelie Schlenz
    Katharina Klaus
    Alexander Schmidt
    Bernd Wöstmann
    Marco Mersmann
    Sabine Ruf
    Niko Christian Bock
    Clinical Oral Investigations, 2023, 27 : 273 - 283
  • [34] Comparison of Milled Full-Arch Implant-Supported Frameworks Realised with a Full Digital Workflow or from Conventional Impression: A Clinical Study
    Pera, Francesco
    Pesce, Paolo
    Bagnasco, Francesco
    Pancini, Nicolo
    Carossa, Massimo
    Baldelli, Lorenzo
    Annunziata, Marco
    Migliorati, Marco
    Baldi, Domenico
    Menini, Maria
    MATERIALS, 2023, 16 (02)
  • [35] Immediate Versus Conventional Loading with Fixed Full-Arch Prostheses in Mandibles with Failing Dentition: A Prospective Controlled Study
    Penarrocha-Oltra, David
    Covani, Ugo
    Penarrocha, Miguel
    Penarrocha-Diago, Maria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (02) : 427 - 434
  • [36] Double Full-Arch Versus Single Full-Arch, Four Implant-Supported Rehabilitations: A Retrospective, 5-Year Cohort Study
    Malo, Paulo
    Nobre, Miguel De Araujo
    Lopes, Armando
    Rodrigues, Rolando
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (04): : 263 - 270
  • [37] Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions
    Zhang, Tingting
    Yang, Bo
    Ge, Ruihan
    Zhang, Chaobiao
    Zhang, Hui
    Wang, Yan
    INTERNATIONAL DENTAL JOURNAL, 2024, 74 (04) : 847 - 854
  • [38] Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies
    Lin Kong
    Yabing Li
    Zhijian Liu
    Clinical Oral Investigations, 2022, 26 : 5625 - 5642
  • [39] Digital versus conventional full-arch impressions in linear and 3D accuracy: a systematic review and meta-analysis of in vivo studies
    Kong, Lin
    Li, Yabing
    Liu, Zhijian
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (09) : 5625 - 5642
  • [40] Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry
    Cheng, Jing
    Zhang, Haidong
    Liu, Hailin
    Li, Junying
    Wang, Hom-Lay
    Tao, Xian
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) : 560 - 572