Digital Versus Conventional Full-Arch Implant Impressions: A Prospective Study on 16 Edentulous Maxillae

被引:94
|
作者
Chochlidakis, Konstantinos [1 ]
Papaspyridakos, Panos [1 ,2 ]
Tsigarida, Alexandra [3 ]
Romeo, Davide [1 ,4 ]
Chen, Yo-wei [2 ]
Natto, Zuhair [5 ,6 ]
Ercoli, Carlo [1 ]
机构
[1] Univ Rochester, Eastman Inst Oral Hlth, Dept Prosthodont, 625 Elmwood Ave, Rochester, NY 14620 USA
[2] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
[3] Univ Rochester, Eastman Inst Oral Hlth, Dept Periodont, Rochester, NY 14620 USA
[4] Univ Vita Salute San Raffaele, San Raffaele Hosp, Adv Oral Surg Unit, Milan, Italy
[5] King Abdulaziz Univ, Dept Dent Publ Hlth, Jeddah, Saudi Arabia
[6] Tufts Univ, Sch Dent Med, Dept Periodontol, Boston, MA 02111 USA
关键词
digital implant scan; accuracy; full-arch; fixed complete denture; ACCURACY; REHABILITATION; TECHNOLOGY; PROSTHESES; WORKFLOW; SURGERY;
D O I
10.1111/jopr.13162
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose A prospective clinical study to compare for the first time the accuracy of digital and conventional maxillary implant impressions for completely edentulous patients. Materials and Methods Sixteen patients received maxillary implant supported fixed complete dentures. After the verification of the conventional final casts, the casts were scanned with a desktop (extraoral) scanner. Intraoral full-arch digital scans were also obtained with scan bodies and STL files. Extraoral and intraoral scans were superimposed and analyzed with reverse engineering software. The primary outcome measure was the assessment of accuracy between scans of the verified conventional casts and digital full-arch impressions. The secondary outcome was the effect of the implant number on the 3D accuracy of impressions with Spearman's rank correlation coefficient. Results The 3D deviations between virtual casts from intraoral full-arch digital scans and digitized final stone casts generated from conventional implant impressions were found to be 162 +/- 77 mu m. In the 4-implant group, 5-implant group, and 6-implant group the 3D deviations were found to be 139 +/- 56 mu m, 146 +/- 90 mu m, and 185 +/- 81 mu m, respectively. There was a positive correlation between increased implant number and 3D-deviations, but there was no statistically significant difference (p = 0.191). Conclusions The 3D accuracy of full-arch digital implant scans lies within previously reported clinically acceptable threshold. Full-arch digital scans and a complete digital workflow in the fabrication of maxillary fixed complete dentures may be clinically feasible.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 50 条
  • [21] Accuracy of full-arch digital impressions: an in vitro and in vivo comparison
    Christine Keul
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 735 - 745
  • [22] Accuracy of digital and conventional implant impressions in edentulous jaws: A clinical comparative study
    Kernen-Gintaute, A.
    Akulauskas, M.
    Kernen, F.
    Zitzmann, N. U.
    Spies, B. C.
    Burkhardt, F.
    JOURNAL OF DENTISTRY, 2025, 153
  • [23] Accuracy of maxillary full-arch digital impressions of tooth and implant models made by two intraoral scanners
    Siadat, Hakimeh
    Chitsaz, Foujan
    Zeighami, Somayeh
    Esmaeilzadeh, Alireza
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (02):
  • [24] In vivo trueness of full-arch implant-supported CAD/CAM restorations and models based on conventional impressions
    Nedelcu, Robert
    Olsson, Pontus
    Thulin, Mans
    Nystrom, Ingela
    Thor, Andreas
    JOURNAL OF DENTISTRY, 2023, 128
  • [25] A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
    Jan-Frederik Güth
    Daniel Edelhoff
    Josef Schweiger
    Christine Keul
    Clinical Oral Investigations, 2016, 20 : 1487 - 1494
  • [26] A new method for the evaluation of the accuracy of full-arch digital impressions in vitro
    Gueth, Jan-Frederik
    Edelhoff, Daniel
    Schweiger, Josef
    Keul, Christine
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (07) : 1487 - 1494
  • [27] Precision of guided scanning procedures for full-arch digital impressions in vivo
    Zimmermann, Moritz
    Koller, Christina
    Rumetsch, Moritz
    Ender, Andreas
    Mehl, Albert
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2017, 78 (06): : 466 - 471
  • [28] Three-Dimensional Accuracy of Conventional Versus Digital Complete Arch Implant Impressions
    Albayrak, Berkman
    Sukotjo, Cortino
    Wee, Alvin G.
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (02): : 163 - 170
  • [29] Accuracy of digital versus conventional implant impressions
    Lee, Sang J.
    Betensky, Rebecca A.
    Gianneschi, Grace E.
    Gallucci, German O.
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) : 715 - 719
  • [30] Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions
    Akkal, Ozcan
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 179 - 188