Open-source image registration for MRI-TRUS fusion-guided prostate interventions

被引:42
作者
Fedorov, Andriy [1 ]
Khallaghi, Siavash [2 ]
Sanchez, C. Antonio [2 ]
Lasso, Andras [3 ]
Fels, Sidney [2 ]
Tuncali, Kemal [1 ]
Sugar, Emily Neubauer [1 ]
Kapur, Tina [1 ]
Zhang, Chenxi [1 ]
Wells, William [1 ]
Nguyen, Paul L. [1 ]
Abolmaesumi, Purang [2 ]
Tempany, Clare [1 ]
机构
[1] Brigham & Womens Hosp, Boston, MA 02115 USA
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Queens Univ, Kingston, ON, Canada
基金
美国国家卫生研究院; 加拿大自然科学与工程研究理事会;
关键词
Prostate cancer; Targeted biopsy; Image-guided interventions; Image registration; Magnetic resonance imaging; Ultrasound; VOLUME;
D O I
10.1007/s11548-015-1180-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose two software tools for non-rigid registration of MRI and transrectal ultrasound (TRUS) images of the prostate. Our ultimate goal is to develop an open-source solution to support MRI-TRUS fusion image guidance of prostate interventions, such as targeted biopsy for prostate cancer detection and focal therapy. It is widely hypothesized that image registration is an essential component in such systems. The two non-rigid registration methods are: (1) a deformable registration of the prostate segmentation distance maps with B-spline regularization and (2) a finite element-based deformable registration of the segmentation surfaces in the presence of partial data. We evaluate the methods retrospectively using clinical patient image data collected during standard clinical procedures. Computation time and Target Registration Error (TRE) calculated at the expert-identified anatomical landmarks were used as quantitative measures for the evaluation. The presented image registration tools were capable of completing deformable registration computation within 5 min. Average TRE was approximately 3 mm for both methods, which is comparable with the slice thickness in our MRI data. Both tools are available under nonrestrictive open-source license. We release open-source tools that may be used for registration during MRI-TRUS-guided prostate interventions. Our tools implement novel registration approaches and produce acceptable registration results. We believe these tools will lower the barriers in development and deployment of interventional research solutions and facilitate comparison with similar tools.
引用
收藏
页码:925 / 934
页数:10
相关论文
共 25 条
[1]   Prebiopsy Magnetic Resonance Imaging and Prostate Cancer Detection: Comparison of Random and Targeted Biopsies [J].
Delongchamps, Nicolas Barry ;
Peyromaure, Michael ;
Schull, Alexandre ;
Beuvon, Frederic ;
Bouazza, Naim ;
Flam, Thierry ;
Zerbib, Marc ;
Muradyan, Naira ;
Legman, Paul ;
Cornud, Francois .
JOURNAL OF UROLOGY, 2013, 189 (02) :493-499
[2]   3D Slicer as an image computing platform for the Quantitative Imaging Network [J].
Fedorov, Andriy ;
Beichel, Reinhard ;
Kalpathy-Cramer, Jayashree ;
Finet, Julien ;
Fillion-Robin, Jean-Christophe ;
Pujol, Sonia ;
Bauer, Christian ;
Jennings, Dominique ;
Fennessy, Fiona ;
Sonka, Milan ;
Buatti, John ;
Aylward, Stephen ;
Miller, James V. ;
Pieper, Steve ;
Kikinis, Ron .
MAGNETIC RESONANCE IMAGING, 2012, 30 (09) :1323-1341
[3]   Image registration for targeted MRI-guided transperineal prostate biopsy [J].
Fedorov, Andriy ;
Tuncali, Kemal ;
Fennessy, Fiona M. ;
Tokuda, Junichi ;
Hata, Nobuhiko ;
Wells, William M. ;
Kikinis, Ron ;
Tempany, Clare M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (04) :987-992
[4]  
Gelas A, 2008, INSIGHT J
[5]   Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer [J].
Hegde, John V. ;
Mulkern, Robert V. ;
Panych, Lawrence P. ;
Fennessy, Fiona M. ;
Fedorov, Andriy ;
Maier, Stephan E. ;
Tempany, Clare M. C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (05) :1035-1054
[6]   CHANGES IN PROSTATE SHAPE AND VOLUME AND THEIR IMPLICATIONS FOR RADIOTHERAPY AFTER INTRODUCTION OF ENDORECTAL BALLOON AS DETERMINED BY MRI AT 3T [J].
Heijmink, Stijn W. T. P. J. ;
Scheenen, Tom W. J. ;
van Lin, Emile N. J. T. ;
Visser, Andries G. ;
Kiemeney, Lambertus A. L. M. ;
Witjes, J. Alfred ;
Barentsz, Jelle O. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05) :1446-1453
[7]   MR to ultrasound registration for image-guided prostate interventions [J].
Hu, Yipeng ;
Ahmed, Hashirn Uddin ;
Taylor, Zeike ;
Allen, Clare ;
Emberton, Mark ;
Hawkes, David ;
Barratt, Dean .
MEDICAL IMAGE ANALYSIS, 2012, 16 (03) :687-703
[8]  
Johnson H, 2007, INSIGHT J
[9]   Real time MRI-ultrasound image guided stereotactic prostate biopsy [J].
Kaplan, I ;
Oldenburg, NE ;
Meskell, P ;
Blake, M ;
Church, P ;
Holupka, EJ .
MAGNETIC RESONANCE IMAGING, 2002, 20 (03) :295-299
[10]   Elastic moduli of breast and prostate tissues under compression [J].
Krouskop, TA ;
Wheeler, TM ;
Kallel, F ;
Garra, BS ;
Hall, T .
ULTRASONIC IMAGING, 1998, 20 (04) :260-274