Hanging drop cathode-atmospheric pressure glow discharge as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry

被引:11
|
作者
Swiderski, Krzysztof [1 ]
Welna, Maja [1 ]
Greda, Krzysztof [1 ]
Pohl, Pawel [1 ]
Jamroz, Piotr [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Chem, Dept Analyt Chem & Chem Met, Wybrzeze Stanislawa Wyspianskiego 27, Wroclaw 50370, Poland
关键词
Hanging drop cathode; Atmospheric pressure glow discharge; Inductively coupled plasma; Optical emission spectrometry; Sample introduction; HYDRIDE GENERATION; VAPOR GENERATION; ULTRASONIC NEBULIZATION; TRACE LEVELS; MERCURY; ENHANCEMENT; SENSITIVITY; IMPROVEMENT;
D O I
10.1007/s00216-020-02685-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work reports the use of hanging drop cathode-atmospheric pressure glow discharge (HDC-APGD) as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry (ICP-OES). The developed arrangement was characterized by a low sample uptake (0.56 mL min(-1)) and the fact that the entire sample solution volume was consumed by the discharge. This resulted in a very high transport efficiency of analytes from the sample solution into the ICP torch (usually > 80%). Under the optimal operating conditions of HDC-APGD, intensities of emission lines of studied elements were, on average, 2 times higher as compared to those obtained with conventional pneumatic nebulization (PN). Moreover, in the case of I and Y, the observed signal enhancements were even higher, i.e., 6.2 and 6.1 times, respectively. It was also shown that in the case of B and some elements that are known to form different volatile species (Ag, Bi, Cd, Hg, Os, Pb, and Se), the presence of low molecular weight organic compounds in the sample solution, i.e., CH3OH, C2H5OH, HCOOH, CH3COOH, or HCHO, resulted in the additional enhancement of their signals. It was especially evident in the case of Hg for which a 8.6-fold signal enhancement in the presence of HCOOH was noticed. The system presented herein was distinguished from other competitive APGD-type discharges because it could be successfully used for the determination of a vast group of elements, including alkali metals, alkaline earth metals, transition metals, and non-metals.
引用
收藏
页码:4211 / 4219
页数:9
相关论文
共 50 条
  • [1] Hanging drop cathode-atmospheric pressure glow discharge as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry
    Krzysztof Swiderski
    Maja Welna
    Krzysztof Greda
    Pawel Pohl
    Piotr Jamroz
    Analytical and Bioanalytical Chemistry, 2020, 412 : 4211 - 4219
  • [2] Determination of bismuth by optical emission spectrometry with liquid anode/cathode atmospheric pressure glow discharge
    Gorska, Monika
    Greda, Krzysztof
    Pohl, Pawel
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (01) : 165 - 177
  • [3] On the coupling of hydride generation with atmospheric pressure glow discharge in contact with the flowing liquid cathode for the determination of arsenic, antimony and selenium with optical emission spectrometry
    Greda, Krzysztof
    Jamroz, Piotr
    Jedryczko, Dominika
    Pohl, Pawel
    TALANTA, 2015, 137 : 11 - 17
  • [4] Atmospheric pressure glow discharge in a contact with liquid as a new excitation source in optical emission spectrometry
    Greda, Krzysztof
    Jamroz, Piotr
    Pohl, Pawel
    PRZEMYSL CHEMICZNY, 2012, 91 (12): : 2389 - 2397
  • [6] High-efficiency photooxidation vapor generation of osmium for determination by inductively coupled plasma-optical emission spectrometry
    Zhu, Zhenli
    He, Dong
    Huang, Chunying
    Zheng, Hongtao
    Zhang, Suicheng
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (03) : 506 - 511
  • [7] SAMPLE INTRODUCTION TECHNIQUES FOR INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY
    HARIMAYA, S
    OKANO, T
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1991, 77 (06): : 752 - 758
  • [8] Particle sample introduction system for inductively coupled plasma-atomic emission spectrometry
    Greib, L
    Karanassios, V
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (02) : 164 - 180
  • [9] Cloud point extraction as sample preparation procedure prior to multielemental analysis by inductively coupled plasma-optical emission spectrometry
    Borkowska-Burnecka, Jolanta
    Jakubiel, Marta
    Zyrnicki, Wieslaw
    CHEMIA ANALITYCZNA, 2008, 53 (03): : 335 - 346
  • [10] A microanalytical method based on electrothermal vaporization capacitively coupled plasma microtorch optical emission spectrometry for multielemental determination: comparison with inductively coupled plasma optical emission spectrometry
    Frentiu, Tiberiu
    Butaciu, Sinziana
    Darvasi, Eugen
    Ponta, Michaela
    Frentiu, Maria
    Petreus, Dorin
    CHEMICAL PAPERS, 2017, 71 (01) : 91 - 102