Endovascular fenestration in aortic dissection with acute malperfusion syndrome: Immediate and late follow-up

被引:56
作者
Midulla, Marco [1 ]
Renaud, Armelle [1 ]
Martinelli, Thomas [1 ]
Koussa, Mohammad [2 ]
Mounier-Vehier, Claire [3 ]
Prat, Alain [4 ]
Beregi, Jean-Paul [1 ]
机构
[1] CHRU, Dept CardioVasc Imaging & Intervent, Hop Cardiol, F-59037 Lille, France
[2] CHRU, Dept CardioVasc Surg, Hop Cardiol, F-59037 Lille, France
[3] CHRU, Dept Vasc Med, Hop Cardiol, F-59037 Lille, France
[4] CHRU, Dept Cardiac Surg, Hop Cardiol, F-59037 Lille, France
关键词
STENT-GRAFT PLACEMENT; INTERNATIONAL REGISTRY; DESCENDING AORTA; ASCENDING AORTA; INTIMAL FLAP; COMPLICATIONS; DIAGNOSIS; ANATOMY; REPAIR;
D O I
10.1016/j.jtcvs.2010.07.081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the immediate and long-term results of fenestration in aortic dissection with acute malperfusion syndrome. Methods: Between 1999 and 2007, 35 patients (31 men; age, 57 +/- 11 years) with aortic dissection (19 with type A and 16 with type B) were treated by fenestration for malperfusion syndrome (27 renal, 27 bowel, and 14 lower limb) due to dynamic compression. Fenestration was performed with 2 rigid guidewires inserted in one 8F sheath (45 cm long). The mean interval between aortic dissection and fenestration was 5 days (28 patients within 3 days and 7 patients between 9 and 41 days). Results: Fenestration (100% technical success rate) with an additional endovascular procedure (29 peripheral stents and 1 thoracic stent graft) resulted in angiographic success in 97% of the patients. Bowel surgery was performed in 7 patients. Mortality within the first month (12/35) was related to bowel ischemia (n - 5), neurologic complications (n = 3), type A surgery (n = 2), and late treatment (n = 2). At a mean follow-up of 48 +/- 30 months, 4 of the remaining 23 patients had died and 2 had withdrawn from the study. The diameter of the aorta, as measured using computed tomography/magnetic resonance imaging, remained stable in 12 of the remaining 17 patients and had increased in 5 (1 with Marfan syndrome and 4 with multiple arterial ectasia). Conclusions: In emergencies, fenestration saved 69% of the patients with acute malperfusion syndrome in complicated aortic dissection. During the follow-up period, the aortic diameter remained stable in most of the surviving patients. (J Thorac Cardiovasc Surg 2011;142:66-72)
引用
收藏
页码:66 / 72
页数:7
相关论文
共 26 条
[21]   Percutaneous balloon fenestration and stenting for life-threatening ischemic complications in patients with acute aortic dissection [J].
Slonim, SM ;
Miller, DC ;
Mitchell, RS ;
Semba, CP ;
Razavi, MK ;
Dake, MD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (06) :1118-1126
[22]   Aortic dissection: A comparative study of diagnosis with spiral CT, multiplanar transesophageal echocardiography, and MR imaging [J].
Sommer, T ;
Fehske, W ;
Holzknecht, N ;
Smekal, AV ;
Keller, E ;
Lutterbey, G ;
Kreft, B ;
Kuhl, C ;
Gieseke, J ;
AbuRamadan, D ;
Schild, H .
RADIOLOGY, 1996, 199 (02) :347-352
[23]  
TAYLOR KM, 1989, DIS HEART, P1338
[24]   Contemporary results of surgery in acute type A aortic dissection: The International Registry of Acute Aortic Dissection experience [J].
Trimarchi, S ;
Nienaber, CA ;
Rampoldi, V ;
Myrmel, T ;
Suzuki, T ;
Mehta, RH ;
Bossone, E ;
Cooper, JV ;
Smith, DE ;
Menicanti, L ;
Frigiola, A ;
Oh, JK ;
Deeb, MG ;
Isselbacher, EM ;
Eagle, KA .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 129 (01) :112-122
[25]   Partial thrombosis of the false lumen in patients with acute type B aortic dissection [J].
Tsai, Thomas T. ;
Evangelista, Arturo ;
Nienaber, Christoph A. ;
Myrmel, Truls ;
Meinhardt, Gabriel ;
Cooper, Jeanna V. ;
Smith, Dean E. ;
Suzuki, Toru ;
Fattori, Rossella ;
Llovet, Alfredo ;
Froehlich, James ;
Hutchison, Stuart ;
Distante, Alessandro ;
Sundt, Thoralf ;
Beckman, Joshua ;
Januzzi, James L., Jr. ;
Isselbacher, Eric M. ;
Eagle, Kim A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (04) :349-359
[26]   The dissected aorta .3. Anatomy and radiologic diagnosis of branch-vessel compromise [J].
Williams, DM ;
Lee, DY ;
Hamilton, BH ;
Marx, MV ;
Narasimham, DL ;
Kazanjian, SN ;
Prince, MR ;
Andrews, JC ;
Cho, KJ ;
Deeb, GM .
RADIOLOGY, 1997, 203 (01) :37-44