Treatment of Cutting and Emulsifying Wastewater Using Non-Thermal Plasma

被引:0
|
作者
Qi Yongtao [1 ]
Chen Jing [1 ]
Liu Tao [1 ]
Zhang Xinmin [1 ]
Liao Xia [1 ]
Cui Can [1 ]
Chen Minggong [1 ]
机构
[1] Anhui Univ Sci & Technol, Sch Chem Engn, Huainan 232001, Anhui, Peoples R China
来源
PROCEEDINGS OF 2010 INTERNATIONAL WORKSHOP ON DIFFUSE POLLUTION-MANAGEMENT MEASURES AND CONTROL TECHNIQUE | 2010年
关键词
non-thermal plasma; emulsion; removal ratio of COD;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The technology of non-thermal plasma was used to treat cutting and emulsifying wastewater and investigate the effect of initial pH value of wastewater, several kinds of inorganic salt or not, velocity of airflow, electrode distance, input voltage, discharge time on wastewater treatment ratio. The experiment results show: the effect of wastewater purifying ratio increases with prolonging the plasma discharge time, the effect of wastewater purifying tends to steady after discharge time exceeds 120min; acidic conditions of wastewater is benefit to improve purifying ratio then basic condition. Putting a little of inorganic salt can increase the effect of wastewater purifying ratio, in this experiment, the effect of CaCl2 is better than Al2(SO4)3, FeSO4, NaCl. The distance between electrodes have more effects of wastewater treatment, the purifying ratio of gas phase discharge is better then liquid phase discharge and gas-liquid interface. Putting air into the wastewater can increase the effect of treatment, but when the velocity of airflow is too high the residence time will be short and then reduce the purifying ratio. The purifying ratio increases with the increasing of input voltage. In this experiment when the input voltage is 25kV, electrode distance 35mm, airflow 0.2L/min, CaCl2 1.6g/L, discharge time 30 min, the removal ratio of COD and turbidity could reach 90% and 92%, respectively.
引用
收藏
页码:340 / 344
页数:5
相关论文
共 12 条
  • [1] CHEN JR, 2004, LOW TEMPERATURE PLAS
  • [2] Chunmei Wang, 1999, STUDY TREATMENT OIL, P05
  • [3] Country Environmental Protection Administration, 2002, GB1320091 COUNTR ENV, P96
  • [4] Country Environmental Protection Administration, 2002, GB1191489 COUNTR ENV, P210
  • [5] Hong Liu, 2000, IND WATER TREATMENT, V20, P22
  • [6] FORMATION OF HYDROXYL RADICALS, HYDROGEN-PEROXIDE AND AQUEOUS ELECTRONS BY PULSED STREAMER CORONA DISCHARGE IN AQUEOUS-SOLUTION
    JOSHI, AA
    LOCKE, BR
    ARCE, P
    FINNEY, WC
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 1995, 41 (01) : 3 - 30
  • [7] Muhammad AM, 2002, PLASMA SOURCES SCI T, V11, P236
  • [8] Optical study of active species produced by a pulsed streamer corona discharge in water
    Sun, B
    Sato, M
    Clements, JS
    [J]. JOURNAL OF ELECTROSTATICS, 1997, 39 (03) : 189 - 202
  • [9] Yuejun Zhang, 2007, PRELIMINARY STUDY TR, P07
  • [10] [朱元右 Zhu Yuanyou], 2004, [工业水处理, Industrial Water Treatment], V24, P13