Modified headholder and operating table for intra-operative MRI in neurosurgery

被引:1
作者
Wirtz, CR
Tronnier, VM
Albert, FK
Knauth, M
Bonsanto, MM
Staubert, A
Pastyr, O
Kunze, S
机构
[1] Univ Heidelberg, Dept Neurosurg, D-69120 Heidelberg, Germany
[2] Univ Heidelberg, Dept Neuroradiol, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Inst Radiol & Pathophysiol, D-6900 Heidelberg, Germany
关键词
MRI; neurosurgery instrumentation; image guided surgery; intra-operative imaging; intra-operative MRI;
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In order to facilitate intra-operative use of magnetic resonance imaging (MRI) in neurosurgery an MRI-compatible headholder was developed and adapted to a modified MR-couch simultaneously serving as tabletop for the operating table. To allow shock-free transport into the scanner the wheels of the operating table were replaced by an air cushion mechanism. In 75 procedures the system proved to be reliable and safe. Image quality was not impaired by the fixation device. With growing routine the transfer became straightforward, requiring approximately 10 min. Intra-operative MRI is thus made possible with minimal changes to the standard surgical environment. Its benefit however, still remains to be critically investigated.
引用
收藏
页码:658 / 661
页数:4
相关论文
共 9 条
[1]   Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications [J].
Black, PM ;
Moriarty, T ;
Alexander, E ;
Stieg, P ;
Woodard, EJ ;
Gleason, PL ;
Martin, CH ;
Kikinis, R ;
Schwartz, RB ;
Jolesz, FA .
NEUROSURGERY, 1997, 41 (04) :831-842
[2]   RIGID HEAD FIXATION FOR INTRAOPERATIVE COMPUTED-TOMOGRAPHY [J].
ENGLE, DJ ;
LUNSFORD, LD ;
PANICHELLI, T .
NEUROSURGERY, 1986, 19 (02) :258-262
[3]  
HECHT ST, 1991, AM J NEURORADIOL, V12, P130
[4]  
KUTH R, 1997, Patent No. 5663646
[5]  
LUNSFORD LD, 1984, NEUROSURGERY, V15, P559
[6]  
Moriarty TM, 1996, NEUROSURG CLIN N AM, V7, P323
[7]   NEW RADIOLUCENT HEAD FIXATION MADE OF ENGINEERING PLASTICS FOR INTRAOPERATIVE CT SCANNING [J].
OKUDERA, H ;
KOBAYASHI, S ;
KYOSHIMA, K ;
TOKUSHIGE, K ;
SUGITA, K .
ACTA NEUROCHIRURGICA, 1994, 127 (1-2) :121-123
[8]   Intraoperative diagnostic and interventional magnetic resonance imaging in neurosurgery [J].
Tronnier, VM ;
Wirtz, CR ;
Knauth, M ;
Lenz, G ;
Pastyr, O ;
Bonsanto, MM ;
Albert, FK ;
Kuth, R ;
Staubert, A ;
Schlegel, W ;
Sartor, K ;
Kunze, S .
NEUROSURGERY, 1997, 40 (05) :891-900
[9]   Correlation of intra-operative ultrasound with histopathologic findings after tumour resection in supratentorial gliomas - A method to improve gross total tumour resection [J].
Woydt, M ;
Krone, A ;
Becker, G ;
Schmidt, K ;
Roggendorf, W ;
Roosen, K .
ACTA NEUROCHIRURGICA, 1996, 138 (12) :1391-1398