Corrosion damage and in-service inspection of retractable sootblower lances in recovery boilers

被引:0
作者
Paoliello, Flavio A. [1 ]
机构
[1] Celulose Nipo Brasileira SA CENIBRA, Tech & Maintenance Dept, Belo Oriente, MG, Brazil
来源
TAPPI JOURNAL | 2021年 / 20卷 / 10期
关键词
Accidents;
D O I
10.32964/TJ20.10.655
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
Several reports of accidents involving serious mechanical failures of sootblower lances in chemical recovery boilers are known in the pulp and paper industry. These accidents mainly consisted of detachment and ejection of the lance tip, or even of the entire lance, to the inside of the furnace, towards the opposite wall. At least one of these cases known to the author resulted in a smelt-water explosion in the boiler. In other events, appreciable damage or near-miss conditions have already been experienced. The risk of catastrophic consequences of the eventual detachment of the lance tip or the complete lance of a recovery boiler sootblower has caught the attention of manufacturers, who have adjusted their quality procedures, but this risk also needs to be carefully considered by the technical staff at pulp mills and in industry committees. This paper briefly describes the failure mechanisms that prevailed in past accidents, while recommending inspection and quality control policies to be applied in order to prevent further occurrences of these dangerous and costly component failures. Digital radiography, in conjunction with other well known inspection techniques, appears to be an effective means to ensure the integrity of sootblower lances in chemical recovery boilers used in the pulp and paper industry. Application: This technical brief raises awareness for an insidious type of component failure and for the consequent threats to recovery boiler safety. Readers may also benefit from understanding the damage mechanisms behind internal corrosion of sootblowers. Recommended inspection and quality control practices and methods complete this brief's preventive scope, helping mills to enhance safety of their recovery boilers.
引用
收藏
页码:655 / 662
页数:8
相关论文
共 9 条
[1]   High-Temperature Failure of a Cast Soot Blower Lance Tube Nozzle [J].
Ackerson, T. N. .
JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2005, 5 (02) :21-24
[2]  
Babcock & Wilcox, DIAM POW GEM NOZZL I
[3]  
BLRBAC, 2018, BLRBAC SPRING M 2018
[4]   Propagation and Attenuation Characteristics of an Ultrasonic Beam in Dissimilar-Metal Welds [J].
Hwang, Young-In ;
Sung, Deokyong ;
Kim, Hak-Joon ;
Song, Sung-Jin ;
Kim, Ki-Bok ;
Kang, Sung-Sik .
SENSORS, 2020, 20 (21) :1-18
[5]  
Jameel MI, 2006, TAPPI J, V5, P18
[6]  
Power, 2017, POWER MAGAZINE
[7]   Recovery boiler sootblowers: History and technological advances [J].
Tran, Honghi ;
Tandra, Danny .
TAPPI JOURNAL, 2015, 14 (01) :51-60
[8]  
Videira J.C, RADIOGRAFIA VERIFICA
[9]  
Zhejiang Lemond Power Equipment, SUPP ROLL LONG RETR