Validity of fluorescent microspheres method for bone blood flow measurement during intentional arterial hypotension

被引:10
作者
Anetzberger, H
Thein, E
Becker, M
Walli, AK
Messmer, K
机构
[1] Univ Munich, Klinikum Grosshadern, Dept Orthopaed, D-81377 Munich, Germany
[2] Univ Munich, Klinikum Grosshadern, Inst Surg Res, D-81377 Munich, Germany
[3] Univ Munich, Klinikum Grosshadern, Inst Clin Chem, D-81377 Munich, Germany
关键词
radioactive microspheres; animal study;
D O I
10.1152/japplphysiol.00299.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In this study, we compared bone blood flow values obtained by simultaneously injected fluorescent ( FM) and radiolabeled microspheres (RM) at stepwise reduced arterial blood pressure. Ten anesthetized female New Zealand White rabbits received simultaneous left ventricular injections of FM and RM at 90, 70, and 50 mmHg mean arterial blood pressure ( MAP). After the experiments, both kidneys and long bones of all four limbs were removed and dissected in a standardized manner. Radioactivity ( corrected for decay, background, and spillover) and fluorescence were determined, and blood flow values were calculated. Relative blood flow values estimated for each bone sample by RM and FM were significantly correlated (r = 0.98, slope = 0.99, and intercept = 0.04 for 90 mmHg; r = 0.98, slope = 0.94, and intercept = 0.09 for 70 mmHg; r = 0.98, slope = 0.96, and intercept = 0.07 for 50 mmHg). Blood flow values (ml . min(-1) . 100 g(-1)) of right and left bone samples determined at the different arterial blood pressures were identical. During moderate hypotension ( 70 mmHg MAP), blood flow in all bone samples remained unchanged compared with 90 mmHg MAP, whereas a significant decrease of bone blood flow was observed at severe hypotension (50 mmHg MAP). Our results demonstrate that the FM technique is valid for measuring bone blood flow. Differences in bone blood flow during altered hemodynamic conditions can be detected reliably. In addition, changes in bone blood flow during hypotension indicate that vasomotor control mechanisms, as well as cardiac output, play a role in setting bone blood flow.
引用
收藏
页码:1153 / 1158
页数:6
相关论文
共 46 条
[1]   BLOOD-FLOW IN RABBIT OSTEOTOMIES STUDIED WITH RADIOACTIVE MICROSPHERES [J].
AALTO, K ;
SLATIS, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06) :637-639
[2]   Determination of regional bone blood flow by means of fluorescent microspheres using an automated sample-processing procedure [J].
Anetzberger, H ;
Thein, E ;
Walli, AK ;
Messmer, K .
EUROPEAN SURGICAL RESEARCH, 2003, 35 (04) :337-345
[3]   QUANTITATING ERROR IN BLOOD-FLOW MEASUREMENTS WITH RADIOACTIVE MICROSPHERES [J].
AUSTIN, RE ;
HAUCK, WW ;
ALDEA, GS ;
FLYNN, AE ;
COGGINS, DL ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01) :H280-H288
[4]   LEFT-VENTRICULAR CANNULATION FOR MICROSPHERE ESTIMATION OF RABBIT RENAL BLOOD-FLOW [J].
BHATTACHARYA, J ;
BEILIN, LJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 238 (05) :H736-H739
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
BROOKES M, 1970, J ANAT, V106, P557
[7]  
Brookes M, 1998, Blood supply of bone, scientific aspects, P75
[8]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[9]   HEMODYNAMICS OF THE JUVENILE DOG KNEE IN RELATION TO INCREASED VENOUS OUTLET RESISTANCE [J].
BUNGER, C ;
BULOW, J ;
HJERMIND, J ;
HARVING, S .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1983, 399 (02) :129-133
[10]   STUDY OF BLOOD FLOW THROUGH BONE MARROW BY A METHOD OF VENOUS EFFLUENT COLLECTION [J].
CUMMING, JD .
JOURNAL OF PHYSIOLOGY-LONDON, 1962, 162 (01) :13-&