Pancreatic malignancy: Value of arterial, pancreatic, and hepatic phase imaging with multi-detector row CT

被引:187
|
作者
Fletcher, JG
Wiersema, MJ
Farrell, MA
Fidler, JL
Burgart, LJ
Koyama, T
Johnson, CD
Stephens, DH
Ward, EM
Harmsen, WS
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Div Gastroenterol & Hepatol, Dept Internal Med & Pathol, Rochester, MN 55905 USA
[3] Mayo Clin, Div Biostat, Rochester, MN 55905 USA
关键词
computed tomography (CT); multi-detection row; phase imaging; pancreas; neoplasms;
D O I
10.1148/radiol.2291020582
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the value of arterial, pancreatic, and hepatic phase imaging at multi-detector row computed tomography (CT) of the pancreas for pancreatic malignancy. MATERIALS AND METHODS: Thirty-nine patients suspected of having resectable pancreatic adenocarcinoma underwent triple-phase multi-detector row CT. Images obtained during each phase were interpreted by one radiologist who evaluated presence of tumor, vascular invasion, and flow artifacts in the superior mesenteric vein and measured attenuation of tumor, normal pancreas, aorta, and superior mesenteric vein. Results were compared with histologic, follow-up, and correlative imaging findings. RESULTS: Mean tumor-to-gland attenuation difference was greatest on images obtained in the pancreatic phase (42 HU) versus that on those obtained in the hepatic phase (35 HU) and in the arterial phase (25 HU). For tumor detection, sensitivity of the images obtained in pancreatic (0.97 [29 of 30]) and hepatic (0.93 [28 of 30]) phases was superior to that of those obtained in arterial phase (0.63 [19 of 30]) (P less than or equal to .008). For vascular invasion detection, sensitivity of images obtained in the hepatic phase (0.83) was better than that of those obtained in the pancreatic (0.58) and arterial (0.25) phases. Images obtained in the pancreatic phase demonstrated more flow artifacts and decreased attenuation in the superior mesenteric vein, compared with the artifacts revealed on images obtained in the hepatic phase. CONCLUSION: Routine acquisition of images in the arterial phase is unnecessary for detection of pancreatic adenocarcinoma. Images of the pancreas obtained in the hepatic phase with multi-detector row CT most accurately display vascular invasion. (C) RSNA, 2003.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 50 条
  • [41] Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: Initial experience
    Juergens, KU
    Grude, M
    Maintz, D
    Fallenberg, EM
    Wichter, T
    Heindel, W
    Fischbach, R
    RADIOLOGY, 2004, 230 (02) : 403 - 410
  • [42] Thoracic aorta at multi-detector row CT: Motion artifact with various reconstruction windows
    Morgan-Hughes, GJ
    Owens, PE
    Marshall, AJ
    Roobottom, CA
    RADIOLOGY, 2003, 228 (02) : 583 - 588
  • [43] Breath-hold three-dimensional CT of the liver with multi-detector row helical CT
    Wong, K
    Paulson, EK
    Nelson, RC
    RADIOLOGY, 2001, 219 (01) : 75 - 79
  • [44] The value of multidetector-row CT in the preoperative detection of pancreatic insulinomas
    Liu, Y.
    Song, Q.
    Jin, H. T.
    Lin, X. Z.
    Chen, K. M.
    RADIOLOGIA MEDICA, 2009, 114 (08): : 1232 - 1238
  • [46] Imaging features of solid pseudopapillary tumor of the pancreas on multi-detector row computed tomography
    Wang, Deng-Bin
    Wang, Qing-Bing
    Chai, Wei-Min
    Chen, Ke-Min
    Deng, Xia-Xing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (07) : 829 - 835
  • [47] Pancreatic arterial anatomy: Depiction with dual-phase helical CT
    Chong, M
    Freeny, PC
    Schmiedl, UP
    RADIOLOGY, 1998, 208 (02) : 537 - 542
  • [48] Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT
    Hunold, P
    Vogt, FM
    Schmermund, A
    Debatin, JF
    Kerkhoff, G
    Budde, T
    Erbel, R
    Ewen, K
    Barkhausen, J
    RADIOLOGY, 2003, 226 (01) : 145 - 152
  • [49] Multiplanar and 3D imaging of the central airways: Comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs
    Boiselle, PM
    Dippolito, G
    Copeland, J
    Kang, HJ
    Ahmed, M
    Weeks, D
    Halpern, E
    Goldberg, SN
    RADIOLOGY, 2003, 228 (01) : 107 - 111
  • [50] Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT
    Yamada, K
    Soejima, T
    Minami, T
    Yoden, E
    Watanabe, Y
    Takenaka, D
    Imai, M
    Okayama, T
    Fujii, M
    Sugimura, K
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01): : 235 - 239