Pancreatic malignancy: Value of arterial, pancreatic, and hepatic phase imaging with multi-detector row CT

被引:187
|
作者
Fletcher, JG
Wiersema, MJ
Farrell, MA
Fidler, JL
Burgart, LJ
Koyama, T
Johnson, CD
Stephens, DH
Ward, EM
Harmsen, WS
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Div Gastroenterol & Hepatol, Dept Internal Med & Pathol, Rochester, MN 55905 USA
[3] Mayo Clin, Div Biostat, Rochester, MN 55905 USA
关键词
computed tomography (CT); multi-detection row; phase imaging; pancreas; neoplasms;
D O I
10.1148/radiol.2291020582
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To assess the value of arterial, pancreatic, and hepatic phase imaging at multi-detector row computed tomography (CT) of the pancreas for pancreatic malignancy. MATERIALS AND METHODS: Thirty-nine patients suspected of having resectable pancreatic adenocarcinoma underwent triple-phase multi-detector row CT. Images obtained during each phase were interpreted by one radiologist who evaluated presence of tumor, vascular invasion, and flow artifacts in the superior mesenteric vein and measured attenuation of tumor, normal pancreas, aorta, and superior mesenteric vein. Results were compared with histologic, follow-up, and correlative imaging findings. RESULTS: Mean tumor-to-gland attenuation difference was greatest on images obtained in the pancreatic phase (42 HU) versus that on those obtained in the hepatic phase (35 HU) and in the arterial phase (25 HU). For tumor detection, sensitivity of the images obtained in pancreatic (0.97 [29 of 30]) and hepatic (0.93 [28 of 30]) phases was superior to that of those obtained in arterial phase (0.63 [19 of 30]) (P less than or equal to .008). For vascular invasion detection, sensitivity of images obtained in the hepatic phase (0.83) was better than that of those obtained in the pancreatic (0.58) and arterial (0.25) phases. Images obtained in the pancreatic phase demonstrated more flow artifacts and decreased attenuation in the superior mesenteric vein, compared with the artifacts revealed on images obtained in the hepatic phase. CONCLUSION: Routine acquisition of images in the arterial phase is unnecessary for detection of pancreatic adenocarcinoma. Images of the pancreas obtained in the hepatic phase with multi-detector row CT most accurately display vascular invasion. (C) RSNA, 2003.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 50 条
  • [1] Pancreatic carcinoma: Developing a protocol for multi-detector row CT
    Johnson, CD
    RADIOLOGY, 2001, 220 (01) : 3 - 4
  • [2] Isoattenuating pancreatic adenocarcinoma at multi-detector row CT: Secondary signs
    Prokesch, RW
    Chow, LC
    Beaulieu, CF
    Bammer, R
    Jeffrey, RB
    RADIOLOGY, 2002, 224 (03) : 764 - 768
  • [3] Local staging of pancreatic carcinoma with multi-detector row CT: Use of curved planar reformations initial experience
    Prokesch, RW
    Chow, LC
    Beaulieu, CF
    Nino-Murcia, M
    Mindelzun, RE
    Barnmer, R
    Huang, J
    Jeffrey, RB
    RADIOLOGY, 2002, 225 (03) : 759 - 765
  • [4] Multi-detector row helical CT of the pancreas: Effect of contrast-enhanced multiphasic imaging on enhancement af the pancreas, peripancreatic vasculature, and pancreatic adenocarcinoma
    McNulty, NJ
    Francis, IR
    Platt, JF
    Cohan, RH
    Korobkin, M
    Gebremariam, A
    RADIOLOGY, 2001, 220 (01) : 97 - 102
  • [5] Hypervascular hepatocellular carcinoma: Detection with double arterial phase multi-detector row helical CT
    Murakami, T
    Kim, T
    Takamura, M
    Hori, M
    Takahashi, S
    Federle, MP
    Tsuda, K
    Osuga, K
    Kawata, S
    Nakamura, H
    Kudo, M
    RADIOLOGY, 2001, 218 (03) : 763 - 767
  • [6] CT colonography: Single-versus multi-detector row imaging
    Hara, AK
    Johnson, CD
    MacCarty, RL
    Welch, TJ
    McCollough, CH
    Harmen, WS
    RADIOLOGY, 2001, 219 (02) : 461 - 465
  • [7] Multi-detector row helical CT angiography of hepatic vessels: Depiction with dual-arterial phase acquisition during single breath hold
    Takahashi, S
    Murakami, T
    Takamura, M
    Kim, T
    Hori, M
    Narumi, Y
    Nakamura, H
    Kudo, M
    RADIOLOGY, 2002, 222 (01) : 81 - 88
  • [8] Hereditary hemorrhagic telangiectasia:: Multi-detector row helical CT assessment of hepatic involvement
    Ianora, AAS
    Memeo, M
    Sabbà, C
    Cirulli, A
    Rotondo, A
    Angelelli, G
    RADIOLOGY, 2004, 230 (01) : 250 - 259
  • [9] Multi-detector row CT urography in the evaluation of hematuria
    Joffe, SA
    Servaes, S
    Okon, S
    Horowitz, M
    RADIOGRAPHICS, 2003, 23 (06) : 1441 - 1455
  • [10] Multi-detector row CT: Radiation dose characteristics
    Hamberg, LM
    Rhea, JT
    Hunter, GJ
    Thrall, JH
    RADIOLOGY, 2003, 226 (03) : 762 - 772