Flow-Sensitive Four-Dimensional Cine Magnetic Resonance Imaging for Offline Blood Flow Quantification in Multiple Vessels: A Validation Study

被引:93
|
作者
Nordmeyer, Sarah [1 ]
Riesenkampff, Eugenie [1 ]
Crelier, Gerard [2 ,3 ]
Khasheei, Alireza [1 ]
Schnackenburg, Bernhard [4 ]
Berger, Felix [1 ]
Kuehne, Titus [1 ]
机构
[1] Deutsch Herzzentrum Berlin, Unit Cardiovasc Imaging, Dept Congenital Heart Dis & Paediat Cardiol, D-13353 Berlin, Germany
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] ETH, Zurich, Switzerland
[4] Philips Med Syst, Hamburg, Germany
关键词
blood flow quantification; congenital heart disease; cardiac; CONGENITAL HEART-DISEASE; TOTAL CAVOPULMONARY CONNECTION; AORTIC-VALVE; WHOLE HEART; 4D FLOW; TIME; VELOCITY; MRI; VISUALIZATION; HEMODYNAMICS;
D O I
10.1002/jmri.22280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To further validate the quantitative use of flow-sensitive four-dimensional velocity encoded cine magnetic resonance imaging (4D VEC MRI) for simultaneously acquired venous and arterial blood flow in healthy volunteers and for abnormal flow in patients with congenital heart disease. Materials and Methods: Stroke volumes (SV) obtained in arterial and venous thoracic vessels were compared between standard two-dimensional (2D), 4D VEC MRI with and without respiratory navigator gating (gated/nongated) in volunteers (n = 7). In addition, SV and regurgitation fractions (RF) measured in aorta or pulmonary trunk of patients with malformed and/or insufficient valves (n = 10) were compared between 2D and nongated 4D VEC MRI methods. Results: In volunteers and patients. Bland-Altman tests showed excellent agreement between 2D. gated, and nongated 4D VEC MRI obtained quantitative blood flow measurements. The bias between 2D and gated 4D VEC MRI was <0.5 mL for SV; between 2D and nongated 4D VEC MRI the bias was <0.7 mL for SV and <1% for RF. Conclusion: Blood flow can be quantified accurately in arterial, venous, and pathological flow conditions using 4D VEC MRI. Nongated 4D VEC MRI has the potential to be suited for clinical use in patients with congenital heart disease who require flow acquisitions in multiple vessels.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 50 条
  • [41] Blood flow dynamics with four-dimensional flow cardiovascular magnetic resonance in patients with aortic stenosis before and after transcatheter aortic valve replacement
    Komoriyama, Hirokazu
    Kamiya, Kiwamu
    Nagai, Toshiyuki
    Oyama-Manabe, Noriko
    Tsuneta, Satonori
    Kobayashi, Yuta
    Kato, Yoshiya
    Sarashina, Miwa
    Omote, Kazunori
    Konishi, Takao
    Sato, Takuma
    Tsujinaga, Shingo
    Iwano, Hiroyuki
    Shingu, Yasushige
    Wakasa, Satoru
    Anzai, Toshihisa
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [42] Additional value and new insights by four-dimensional flow magnetic resonance imaging in congenital heart disease: application in neonates and young children
    Julia Geiger
    Fraser M. Callaghan
    Barbara E. U. Burkhardt
    Emanuela R. Valsangiacomo Buechel
    Christian J. Kellenberger
    Pediatric Radiology, 2021, 51 : 1503 - 1517
  • [43] Quantification of Thoracic Blood Flow Using Volumetric Magnetic Resonance Imaging With Radial Velocity Encoding In Vivo Validation
    Frydrychowicz, Alex
    Wieben, Oliver
    Niespodzany, Eric
    Reeder, Scott B.
    Johnson, Kevin M.
    Francois, Christopher J.
    INVESTIGATIVE RADIOLOGY, 2013, 48 (12) : 819 - 825
  • [44] 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography
    Maya Gabbour
    Susanne Schnell
    Kelly Jarvis
    Joshua D. Robinson
    Michael Markl
    Cynthia K. Rigsby
    Pediatric Radiology, 2015, 45 : 804 - 813
  • [45] Aortic Relative Pressure Components Derived from Four-Dimensional Flow Cardiovascular Magnetic Resonance
    Lamata, Pablo
    Pitcher, Alex
    Krittian, Sebastian
    Nordsletten, David
    Bissell, Malenka M.
    Cassar, Thomas
    Barker, Alex J.
    Markl, Michael
    Neubauer, Stefan
    Smith, Nicolas P.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 1162 - 1169
  • [46] Cardiac magnetic resonance using fused 3D cine and 4D flow sequences:Validation of ventricular and blood flow measurements
    Moghari, Mehdi H.
    van der Geest, Rob J.
    Brighenti, Maurizio
    Powell, Andrew J.
    MAGNETIC RESONANCE IMAGING, 2020, 74 : 203 - 212
  • [47] Evaluation of Left Ventricular Function Using Four-Dimensional Flow Cardiovascular Magnetic Resonance: A Systematic Review
    Qin, Jiaxing Jason
    Indja, Ben
    Gholipour, Alireza
    Gok, Mustafa
    Grieve, Stuart M.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (09)
  • [48] Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review
    Crandon, Saul
    Elbaz, Mohammed S. M.
    Westenberg, Jos J. M.
    van der Geest, Rob J.
    Plein, Sven
    Garg, Pankaj
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 249 : 486 - 493
  • [49] Denoising four-dimensional flow magnetic resonance imaging data using a split-and-overlap approach via singular value decomposition
    Kang, Seungmin
    An, Don-Gwan
    Ha, Hojin
    Yang, Dong Hyun
    Jang, Ilhoon
    Song, Simon
    PHYSICS OF FLUIDS, 2024, 36 (01)
  • [50] Reference Ranges of Blood Flow in the Major Vessels of the Normal Human Fetal Circulation at Term by Phase-Contrast Magnetic Resonance Imaging
    Prsa, Milan
    Sun, Liqun
    van Amerom, Joshua
    Yoo, Shi-Joon
    Grosse-Wortmann, Lars
    Jaeggi, Edgar
    Macgowan, Christopher
    Seed, Mike
    CIRCULATION-CARDIOVASCULAR IMAGING, 2014, 7 (04) : 663 - 670