Flow-Sensitive Four-Dimensional Cine Magnetic Resonance Imaging for Offline Blood Flow Quantification in Multiple Vessels: A Validation Study

被引:93
|
作者
Nordmeyer, Sarah [1 ]
Riesenkampff, Eugenie [1 ]
Crelier, Gerard [2 ,3 ]
Khasheei, Alireza [1 ]
Schnackenburg, Bernhard [4 ]
Berger, Felix [1 ]
Kuehne, Titus [1 ]
机构
[1] Deutsch Herzzentrum Berlin, Unit Cardiovasc Imaging, Dept Congenital Heart Dis & Paediat Cardiol, D-13353 Berlin, Germany
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] ETH, Zurich, Switzerland
[4] Philips Med Syst, Hamburg, Germany
关键词
blood flow quantification; congenital heart disease; cardiac; CONGENITAL HEART-DISEASE; TOTAL CAVOPULMONARY CONNECTION; AORTIC-VALVE; WHOLE HEART; 4D FLOW; TIME; VELOCITY; MRI; VISUALIZATION; HEMODYNAMICS;
D O I
10.1002/jmri.22280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To further validate the quantitative use of flow-sensitive four-dimensional velocity encoded cine magnetic resonance imaging (4D VEC MRI) for simultaneously acquired venous and arterial blood flow in healthy volunteers and for abnormal flow in patients with congenital heart disease. Materials and Methods: Stroke volumes (SV) obtained in arterial and venous thoracic vessels were compared between standard two-dimensional (2D), 4D VEC MRI with and without respiratory navigator gating (gated/nongated) in volunteers (n = 7). In addition, SV and regurgitation fractions (RF) measured in aorta or pulmonary trunk of patients with malformed and/or insufficient valves (n = 10) were compared between 2D and nongated 4D VEC MRI methods. Results: In volunteers and patients. Bland-Altman tests showed excellent agreement between 2D. gated, and nongated 4D VEC MRI obtained quantitative blood flow measurements. The bias between 2D and gated 4D VEC MRI was <0.5 mL for SV; between 2D and nongated 4D VEC MRI the bias was <0.7 mL for SV and <1% for RF. Conclusion: Blood flow can be quantified accurately in arterial, venous, and pathological flow conditions using 4D VEC MRI. Nongated 4D VEC MRI has the potential to be suited for clinical use in patients with congenital heart disease who require flow acquisitions in multiple vessels.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 50 条
  • [21] Quantification and mapping of cerebral hemodynamics before and after carotid endarterectomy, using four-dimensional flow magnetic resonance imaging
    Zarrinkoob, Laleh
    Wahlin, Anders
    Ambarki, Khalid
    Eklund, Anders
    Malm, Jan
    JOURNAL OF VASCULAR SURGERY, 2021, 74 (03) : 910 - +
  • [22] 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography
    Gabbour, Maya
    Schnell, Susanne
    Jarvis, Kelly
    Robinson, Joshua D.
    Markl, Michael
    Rigsby, Cynthia K.
    PEDIATRIC RADIOLOGY, 2015, 45 (06) : 804 - 813
  • [23] Modeling Physiological Flow in Fontan Models With Four-Dimensional Flow Magnetic Resonance Imaging, Particle Image Velocimetry, and Arterial Spin Labeling
    Rutkowski, David R.
    Medero, Rafael
    Ruesink, Timothy A.
    Roldan-Alzate, Alejandro
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (12):
  • [24] A Four-dimensional Motion Field Atlas of the Tongue from Tagged and Cine Magnetic Resonance Imaging
    Xing, Fangxu
    Prince, Jerry L.
    Stone, Maureen
    Wedeen, Van J.
    El Fakhri, Georges
    Woo, Jonghye
    MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [25] In Vivo Quantification of Helical Blood Flow in Human Aorta by Time-Resolved Three-Dimensional Cine Phase Contrast Magnetic Resonance Imaging
    Morbiducci, Umberto
    Ponzini, Raffaele
    Rizzo, Giovanna
    Cadioli, Marcello
    Esposito, Antonio
    De Cobelli, Francesco
    Del Maschio, Alessandro
    Montevecchi, Franco Maria
    Redaelli, Alberto
    ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (03) : 516 - 531
  • [26] Fat delays emptying but increases forward and backward antral flow as assessed by flow-sensitive magnetic resonance imaging
    Boulby, P
    Moore, R
    Gowland, P
    Spiller, RC
    NEUROGASTROENTEROLOGY AND MOTILITY, 1999, 11 (01) : 27 - 36
  • [27] Inflow hemodynamics evaluated by using four-dimensional flow magnetic resonance imaging and the size ratio of unruptured cerebral aneurysms
    Futami, Kazuya
    Nambu, Iku
    Kitabayashi, Tomohiro
    Sano, Hiroki
    Misaki, Kouichi
    Uchiyama, Naoyuki
    Nakada, Mitsutoshi
    NEURORADIOLOGY, 2017, 59 (04) : 411 - 418
  • [28] Impact of measurement location on direct mitral regurgitation quantification using four-dimensional flow cardiovascular magnetic resonance
    Aratikatla, Adarsh
    Safder, Taimur
    Ayuba, Gloria
    Appadurai, Vinesh
    Gupta, Aakash
    Markl, Michael
    Thomas, James
    Lee, Jeesoo
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2025, 27 (01)
  • [29] Evaluation of Flow Pattern in the Ascending Aorta in Patients with Repaired Tetralogy of Fallot Using Four-Dimensional Flow Magnetic Resonance Imaging
    Lee, Suji
    Kim, Young Jin
    Jung, Jo Won
    Choi, Jae Young
    Park, Han Ki
    Shin, Yu Rim
    Choi, Byung Wook
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (09) : 1334 - 1341
  • [30] Four-Dimensional Flow Magnetic Resonance Imaging for Assessment of Velocity Magnitudes and Flow Patterns in The Human Carotid Artery Bifurcation: Comparison with Computational Fluid Dynamics
    Ngo, Minh Tri
    Kim, Chul In
    Jung, Jinmu
    Chung, Gyung Ho
    Lee, Dong Hwan
    Kwak, Hyo Sung
    DIAGNOSTICS, 2019, 9 (04)