Flow-Sensitive Four-Dimensional Cine Magnetic Resonance Imaging for Offline Blood Flow Quantification in Multiple Vessels: A Validation Study

被引:93
|
作者
Nordmeyer, Sarah [1 ]
Riesenkampff, Eugenie [1 ]
Crelier, Gerard [2 ,3 ]
Khasheei, Alireza [1 ]
Schnackenburg, Bernhard [4 ]
Berger, Felix [1 ]
Kuehne, Titus [1 ]
机构
[1] Deutsch Herzzentrum Berlin, Unit Cardiovasc Imaging, Dept Congenital Heart Dis & Paediat Cardiol, D-13353 Berlin, Germany
[2] Univ Zurich, Inst Biomed Engn, Zurich, Switzerland
[3] ETH, Zurich, Switzerland
[4] Philips Med Syst, Hamburg, Germany
关键词
blood flow quantification; congenital heart disease; cardiac; CONGENITAL HEART-DISEASE; TOTAL CAVOPULMONARY CONNECTION; AORTIC-VALVE; WHOLE HEART; 4D FLOW; TIME; VELOCITY; MRI; VISUALIZATION; HEMODYNAMICS;
D O I
10.1002/jmri.22280
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To further validate the quantitative use of flow-sensitive four-dimensional velocity encoded cine magnetic resonance imaging (4D VEC MRI) for simultaneously acquired venous and arterial blood flow in healthy volunteers and for abnormal flow in patients with congenital heart disease. Materials and Methods: Stroke volumes (SV) obtained in arterial and venous thoracic vessels were compared between standard two-dimensional (2D), 4D VEC MRI with and without respiratory navigator gating (gated/nongated) in volunteers (n = 7). In addition, SV and regurgitation fractions (RF) measured in aorta or pulmonary trunk of patients with malformed and/or insufficient valves (n = 10) were compared between 2D and nongated 4D VEC MRI methods. Results: In volunteers and patients. Bland-Altman tests showed excellent agreement between 2D. gated, and nongated 4D VEC MRI obtained quantitative blood flow measurements. The bias between 2D and gated 4D VEC MRI was <0.5 mL for SV; between 2D and nongated 4D VEC MRI the bias was <0.7 mL for SV and <1% for RF. Conclusion: Blood flow can be quantified accurately in arterial, venous, and pathological flow conditions using 4D VEC MRI. Nongated 4D VEC MRI has the potential to be suited for clinical use in patients with congenital heart disease who require flow acquisitions in multiple vessels.
引用
收藏
页码:677 / 683
页数:7
相关论文
共 50 条
  • [1] Four-dimensional velocity-encoded magnetic resonance imaging improves blood flow quantification in patients with complex accelerated flow
    Nordmeyer, Sarah
    Riesenkampff, Eugenie
    Messroghli, Daniel
    Kropf, Siegfried
    Nordmeyer, Johannes
    Berger, Felix
    Kuehne, Titus
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (01) : 208 - 216
  • [2] Four-dimensional Flow Magnetic Resonance Imaging Quantification of Blood Flow in Bicuspid Aortic Valve
    Gordon, Daniel Z.
    Abbasi, Muhannad A.
    Lee, Jeesoo
    Sarnari, Roberto
    Sojoudi, Alireza
    Wei, Qiao
    Scott, Michael B.
    Collins, Jeremy D.
    Allen, Bradley D.
    Blaisdell, Julie A.
    Carr, James C.
    Markl, Michael
    JOURNAL OF THORACIC IMAGING, 2020, 35 (06) : 383 - 388
  • [3] Four-Dimensional Flow Magnetic Resonance Imaging in the Assessment of Blood Flow in the Heart and Great Vessels: A Systematic Review
    Doyle, Ciara M.
    Orr, Jenny
    Greenwood, John P.
    Plein, Sven
    Tsoumpas, Charalampos
    Bissell, Malenka M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (05) : 1301 - 1321
  • [4] Four-dimensional flow magnetic resonance imaging in cirrhosis
    Stankovic, Zoran
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (01) : 89 - 102
  • [5] Four-dimensional flow magnetic resonance imaging in cirrhosis
    Zoran Stankovic
    World Journal of Gastroenterology, 2016, (01) : 89 - 102
  • [6] Four-Dimensional flow Magnetic Resonance Imaging for Assessment of Pediatric Coarctation of the Aorta
    Desai, Lajja
    Stefek, Heather
    Berhane, Haben
    Robinson, Joshua
    Rigsby, Cynthia
    Markl, Michael
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (01) : 200 - 208
  • [7] Flow-sensitive four-dimensional magnetic resonance imaging facilitates and improves the accurate diagnosis of partial anomalous pulmonary venous drainage
    Nordmeyer, Sarah
    Berger, Felix
    Kuehne, Titus
    Riesenkampff, Eugenie
    CARDIOLOGY IN THE YOUNG, 2011, 21 (05) : 528 - 535
  • [8] Four-dimensional flow cardiovascular magnetic resonance: Towards accurate flow quantification?
    Garot, Jerome
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2019, 112 (04) : 223 - 225
  • [9] Aortic flow patterns in patients with Marfan syndrome assessed by flow-sensitive four-dimensional MRI
    Geiger, Julia
    Markl, Michael
    Herzer, Lena
    Hirtler, Daniel
    Loeffelbein, Florian
    Stiller, Brigitte
    Langer, Mathias
    Arnold, Raoul
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (03) : 594 - 600
  • [10] Flow dynamics of type II endoleaks can determine sac expansion after endovascular aneurysm repair using four-dimensional flow-sensitive magnetic resonance imaging analysis
    Katahashi, Kazuto
    Sano, Masaki
    Takehara, Yasuo
    Inuzuka, Kazunori
    Sugiyama, Masataka
    Alley, Marcus T.
    Takeuchi, Hiroya
    Unno, Naoki
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (01) : 107 - +