Decision tree approach for classification and dimensionality reduction of electronic nose data

被引:93
作者
Cho, Jung Hwan [1 ]
Kurup, Pradeep U. [1 ]
机构
[1] Univ Massachusetts Lowell, Dept Civil & Environm Engn, Lowell, MA 01854 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 160卷 / 01期
基金
美国国家科学基金会;
关键词
Decision tree; C4.5; CART; Classification; Dimensionality reduction; Feature selection; Sensor parameter; Dynamic sensor response; SENSOR ARRAY; GAS SENSORS; SELECTION; RECOGNITION; MACHINE;
D O I
10.1016/j.snb.2011.08.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a decision tree approach using two different tree models, C4.5 and CART, for use in the classification and dimensionality reduction of electronic nose (EN) data. The decision tree is a tree structure consisting of internal and terminal nodes which process the data to ultimately yield a classification. The decision tree is proficient at both maintaining the role of dimensionality reduction and at organizing optimally sized classification trees, and therefore it could be a promising approach to analyze EN data. In the experiments conducted, six sensor response parameters were extracted from the dynamic sensor responses of each of the four metal oxide gas sensors. The six parameters observed were the rising time (T-r), falling time (T-f), total response time (T-t), normalized peak voltage change (y(p,n)), normalized curve integral (C-I), and triangle area (T-A). One sensor parameter from each metal oxide sensor was used for the classification trees, and the best classification accuracy of 97.78% was achieved by CART using the CI parameter. However, the accuracy of CART was improved using all of the sensor parameters as inputs to the classification tree. The improved results of CART, having an accuracy of 98.89%, was comparable to that of two popular classifiers, the multilayer perceptron (MLP) neural network and the fuzzy ARTMAP network (accuracy of 98.89%, and 100%, respectively). Furthermore, as a dimensionality reduction method the decision tree has shown a better discrimination accuracy of 100% for the MLP classifier and 98.89% for the fuzzy ARTMAP classifier as compared to those achieved with principle component analysis (PCA) giving 81.11% and 97.78%, and a variable selection method giving 92.22% and 93.33% (for the same MLP and fuzzy ARTMAP classifiers). Therefore, a decision tree could be a promising technique for a pattern recognition system for EN data in terms of two functions; as classifier which is an optimally organized classification tree, and as dimensionality reduction method for other pattern recognition techniques. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:542 / 548
页数:7
相关论文
共 26 条
[1]   Optical-fiber arrays for vapor sensing [J].
Aernecke, Matthew J. ;
Walt, David R. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (02) :464-469
[2]  
[Anonymous], 2014, C4. 5: programs for machine learning
[3]  
[Anonymous], 1984, OLSHEN STONE CLASSIF, DOI 10.2307/2530946
[4]  
[Anonymous], 2003, ELECT SENSOR TECHNOL
[5]   Design of a very large chemical sensor system for mimicking biological olfaction [J].
Beccherelli, R. ;
Zampetti, E. ;
Pantalei, S. ;
Bernabei, M. ;
Persaud, K. C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 146 (02) :446-452
[6]   Discrimination between different samples of olive oil using variable selection techniques and modified fuzzy artmap neural networks [J].
Brezmes, J ;
Cabré, P ;
Rojo, S ;
Llobet, E ;
Vilanova, X ;
Correig, X .
IEEE SENSORS JOURNAL, 2005, 5 (03) :463-470
[7]   Electronic noses sniff success [J].
Chang, Josephine B. ;
Subramanian, Vivek .
IEEE SPECTRUM, 2008, 45 (03) :50-+
[8]   Wireless electronic nose system for real-time quantitative analysis of gas mixtures using micro-gas sensor array and neuro-fuzzy network [J].
Cho, Jung Hwan ;
Kim, Young Woung ;
Na, Kyung Jin ;
Jeon, Gi Joon .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01) :104-111
[9]   An artificial olfaction system based on the optical imaging of a large array of chemical reporters [J].
Di Natale, C. ;
Martinelli, E. ;
Paolesse, R. ;
D'Amico, A. ;
Filippini, D. ;
Lundstrom, I. .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 142 (02) :412-417
[10]   Enhanced selectivity of MOSFET gas sensors by systematical analysis of transient parameters [J].
Eklov, T ;
Martensson, P ;
Lundstrom, I .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :291-300