The effect of aortic area measurement site on the energy loss coefficient: a comparison between echocardiography and cardiac computed tomography angiography in patients with aortic stenosis

被引:2
作者
Yaari, Dotan [1 ]
Rubinshtein, Ronen [1 ,2 ]
Sachner, Robert [3 ]
Gaspar, Tamar [1 ,3 ]
Adawi, Salim [1 ,2 ]
Jaffe, Ronen [1 ,2 ]
Asmer, Ihab [2 ]
Ganaeem, Majdi [2 ]
Shiran, Avinoam [1 ,2 ]
机构
[1] Technion Israel Inst Technol, Ruth & Bruce Rappaport Fac Med, Haifa, Israel
[2] Lady Davis Carmel Med Ctr, Dept Cardiovasc Med, Haifa, Israel
[3] Lady Davis Carmel Med Ctr, Dept Radiol, Haifa, Israel
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2016年 / 33卷 / 11期
关键词
aortic stenosis; cardiac computed tomography angiography; energy loss coefficient; energy loss index; transthoracic echocardiography; PRESSURE RECOVERY; VALVE AREA; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DOPPLER-ECHOCARDIOGRAPHY; ORIFICE AREA; RECOMMENDATIONS; PLANIMETRY; IMPACT; ULTRASOUND; GRADIENTS;
D O I
10.1111/echo.13331
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimThe energy loss coefficient (ELCo) has been suggested as a more accurate indicator of aortic stenosis (AS) severity as compared to transthoracic echocardiography (TTE) aortic valve area (AVA). There are little data regarding the optimal location for aortic area (Aa) measurement needed for ELCo calculation and the agreement of ELCo with direct anatomical AVA measurement. The aim of this study was to determine the optimal site of Aa measurement for calculation of the ELCo, using cardiac computed tomography angiography (CCTA) AVA planimetry as the reference standard. MethodsWe analyzed 69 patients with AS who underwent both CCTA and TTE. ELCo and CCTA planimetry AVA were compared using multiple sites for CCTA Aa measurement (sinus, sinotubular junction, or ascending aorta). ResultsCCTA AVA was 0.960.46cm(2). ELCo was 0.95 +/- 0.43cm(2) using sinotubular junction Aa, 0.92 +/- 0.41cm(2) using sinus Aa, and 0.91 +/- 0.4cm(2) using the ascending aorta (P=.84, P=.13, and P=.08 compared to CCTA AVA). There was good agreement between CCTA AVA and ELCo using all Aa locations (0.89-0.90). On subgroup analysis of 16 patients most likely to be affected by pressure recovery (aortic diameter<3cm and AVA 1cm(2)), ELCo using the sinotubular junction Aa showed the best agreement with CCTA AVA as compared to the other Aa locations (0.84 vs 0.75-0.77). ConclusionsELCo using Aa measurement at the sinotubular junction showed the best agreement with CCTA AVA. We therefore recommend using the sinotubular junction Aa for ELCo calculation.
引用
收藏
页码:1649 / 1655
页数:7
相关论文
共 50 条
  • [31] Discrepancies between cardiovascular magnetic resonance and Doppler echocardiography in the measurement of transvalvular gradient in aortic stenosis: the effect of flow vorticity
    Garcia, Julio
    Capoulade, Romain
    Le Ven, Florent
    Gaillard, Emmanuel
    Kadem, Lyes
    Pibarot, Philippe
    Larose, Eric
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [32] Non-invasive and invasive evaluation of aortic valve area in 100 patients with severe aortic valve stenosis: Comparison of cardiac computed tomography with ECHO (transesophageal/transthoracic) and catheter examination
    Anger, Thomas
    Bauer, Verena
    Plachtzik, Claudia
    Geisler, Tobias
    Gawaz, Meinrad P.
    Oberhoff, Martin
    Hoeher, Martin
    [J]. JOURNAL OF CARDIOLOGY, 2014, 63 (3-4) : 189 - 197
  • [33] Predominant determinants for evaluation of right parasternal approach in transthoracic echocardiography in aortic stenosis: a study based on three-dimensional cardiac computed tomography analysis
    Yokokawa, Daisuke
    Kuroki, Yui
    Mochizuki, Yasuhide
    Oda, Ayaka
    Gohbara, Sakiko
    Yamamoto, Yumi
    Ichikawa-Ogura, Saaya
    Hachiya, Rumi
    Toyosaki, Eiji
    Fukuoka, Hiroto
    Sunagawa, Masataka
    Shinke, Toshiro
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (08) : 1713 - 1724
  • [34] Grading of aortic stenosis severity: a head-to-head comparison between cardiac magnetic resonance imaging and echocardiography
    Cesare Mantini
    Gabriele Di Giammarco
    Jacopo Pizzicannella
    Sabina Gallina
    Fabrizio Ricci
    Emilia D’Ugo
    Marziale Marchetti
    Antonio Raffaele Cotroneo
    Nauman Ahmed
    Chiara Bucciarelli-Ducci
    Armando Tartaro
    Raffaele De Caterina
    [J]. La radiologia medica, 2018, 123 : 643 - 654
  • [35] Grading Aortic Stenosis With Mean Gradient and Aortic Valve Area: A Comparison Between Preoperative Transthoracic and Precardiopulmonary Bypass Transesophageal Echocardiography
    Whitener, George
    Sivak, Joseph
    Akushevich, Igor
    Samad, Zainab
    Swaminathan, Madhav
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (05) : 1254 - 1259
  • [36] Multimodality imaging in transcatheter aortic valve implantation (TAVI): comparison between cardiovascular magnetic resonance, cardiac computed tomography and echocardiography
    Andrew J.
    Okoroafor F.
    Park B.
    Roussin I.
    Alpendurada F.
    Ismail T.
    Paes M.N.
    Davies S.
    Mullen M.J.
    Delahunty N.
    Prasad S.
    Rubens M.
    Moat N.
    Mohiaddin R.
    [J]. Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [37] Evaluation of Aortic Valve Stenosis by Cardiac Multi-Slice Computed Tomography Compared with Echocardiography: A Systematic Review and Meta-Analysis
    Abdulla, Jawdat
    Sivertsen, Jacob
    Kofoed, Klaus Fuglsang
    Alkadhi, Hatem
    LaBounty, Troy
    Abildstrom, Steen Z.
    Kober, Lars
    Christensen, Erik
    Torp-Pedersen, Christian
    [J]. JOURNAL OF HEART VALVE DISEASE, 2009, 18 (06) : 634 - 643
  • [38] Usefulness of routine aortic valve calcium score measurement for risk stratification of aortic stenosis and coronary artery disease in patients scheduled cardiac multislice computed tomography
    Shimizu, Kazuki
    Yamamoto, Masanori
    Koyama, Yutaka
    Kodama, Atsuko
    Sato, Hirotomo
    Kano, Seiji
    Teramoto, Tomohiko
    Kimura, Masashi
    Sawada, Koshi
    Goto, Yoshihiro
    Ogawa, Shinji
    Baba, Hiroshi
    Tsuchikane, Etsuo
    Okawa, Yasuhide
    Suzuki, Takahiko
    [J]. IJC HEART & VASCULATURE, 2015, 9 : 95 - 99
  • [39] Quantification of Congenital Aortic Valve Stenosis in Pediatric Patients: Comparison Between Cardiac Magnetic Resonance Imaging and Transthoracic Echocardiography
    Sirin, Selma
    Nassenstein, Kai
    Neudorf, Ulrich
    Jensen, Christoph J.
    Mikat, Christian
    Schlosser, Thomas
    [J]. PEDIATRIC CARDIOLOGY, 2014, 35 (05) : 771 - 777
  • [40] Assessment of Aortic Stenosis Severity in Low-Flow Low-Gradient Aortic Stenosis: Comparison of Dobutamine Stress Echocardiography and Aortic Valve Calcium Scoring by Computed Tomography -The TOPAS Study-
    Dahou, Abdellaziz
    Cleve, Marie-Annick
    Larose, Eric
    Capoulade, Romain
    Bartko, Philipp E.
    Ribeiro, Henrique B.
    Tastet, Lionel
    Bergler-Klein, Jutta
    Mundigler, Gerald
    Burwash, Ian
    Dumesnil, Jean G.
    Senechal, Mario
    O'Connor, Kim
    Baumgartner, Helmut
    Rodes-Cabau, Josep
    Pibarot, Philippe
    [J]. CIRCULATION, 2014, 130