The effect of aortic area measurement site on the energy loss coefficient: a comparison between echocardiography and cardiac computed tomography angiography in patients with aortic stenosis

被引:2
作者
Yaari, Dotan [1 ]
Rubinshtein, Ronen [1 ,2 ]
Sachner, Robert [3 ]
Gaspar, Tamar [1 ,3 ]
Adawi, Salim [1 ,2 ]
Jaffe, Ronen [1 ,2 ]
Asmer, Ihab [2 ]
Ganaeem, Majdi [2 ]
Shiran, Avinoam [1 ,2 ]
机构
[1] Technion Israel Inst Technol, Ruth & Bruce Rappaport Fac Med, Haifa, Israel
[2] Lady Davis Carmel Med Ctr, Dept Cardiovasc Med, Haifa, Israel
[3] Lady Davis Carmel Med Ctr, Dept Radiol, Haifa, Israel
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2016年 / 33卷 / 11期
关键词
aortic stenosis; cardiac computed tomography angiography; energy loss coefficient; energy loss index; transthoracic echocardiography; PRESSURE RECOVERY; VALVE AREA; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DOPPLER-ECHOCARDIOGRAPHY; ORIFICE AREA; RECOMMENDATIONS; PLANIMETRY; IMPACT; ULTRASOUND; GRADIENTS;
D O I
10.1111/echo.13331
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimThe energy loss coefficient (ELCo) has been suggested as a more accurate indicator of aortic stenosis (AS) severity as compared to transthoracic echocardiography (TTE) aortic valve area (AVA). There are little data regarding the optimal location for aortic area (Aa) measurement needed for ELCo calculation and the agreement of ELCo with direct anatomical AVA measurement. The aim of this study was to determine the optimal site of Aa measurement for calculation of the ELCo, using cardiac computed tomography angiography (CCTA) AVA planimetry as the reference standard. MethodsWe analyzed 69 patients with AS who underwent both CCTA and TTE. ELCo and CCTA planimetry AVA were compared using multiple sites for CCTA Aa measurement (sinus, sinotubular junction, or ascending aorta). ResultsCCTA AVA was 0.960.46cm(2). ELCo was 0.95 +/- 0.43cm(2) using sinotubular junction Aa, 0.92 +/- 0.41cm(2) using sinus Aa, and 0.91 +/- 0.4cm(2) using the ascending aorta (P=.84, P=.13, and P=.08 compared to CCTA AVA). There was good agreement between CCTA AVA and ELCo using all Aa locations (0.89-0.90). On subgroup analysis of 16 patients most likely to be affected by pressure recovery (aortic diameter<3cm and AVA 1cm(2)), ELCo using the sinotubular junction Aa showed the best agreement with CCTA AVA as compared to the other Aa locations (0.84 vs 0.75-0.77). ConclusionsELCo using Aa measurement at the sinotubular junction showed the best agreement with CCTA AVA. We therefore recommend using the sinotubular junction Aa for ELCo calculation.
引用
收藏
页码:1649 / 1655
页数:7
相关论文
共 50 条
  • [21] Quantification of Significant Aortic Stenosis by Echocardiography versus Four-Dimensional Cardiac Computed Tomography: A Multi-Modality Imaging Study
    Wang, Tom Kai Ming
    Abou Hassan, Ossama K.
    Popovic, Zoran B.
    Griffin, Brian P.
    Rodriguez, Luis Leonardo
    DIAGNOSTICS, 2022, 12 (12)
  • [22] Multimodality Imaging in Transcatheter Aortic Valve Implantation and Post-Procedural Aortic Regurgitation Comparison Among Cardiovascular Magnetic Resonance, Cardiac Computed Tomography, and Echocardiography
    Jabbour, Andrew
    Ismail, Tevfik F.
    Moat, Neil
    Gulati, Ankur
    Roussin, Isabelle
    Alpendurada, Francisco
    Park, Bradley
    Okoroafor, Francois
    Asgar, Anita
    Barker, Sarah
    Davies, Simon
    Prasad, Sanjay K.
    Rubens, Michael
    Mohiaddin, Raad H.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) : 2165 - 2173
  • [23] Comparison of left atrial strain measured by feature tracking computed tomography and speckle tracking echocardiography in patients with aortic stenosis
    Hirasawa, Kensuke
    Kuneman, Jurrien H.
    Singh, Gurpreet K.
    Gegenava, Tea
    Hautemann, David
    Reiber, Johan H. C.
    Marsan, Nina Ajmone
    Bax, Jeroen J.
    Delgado, Victoria
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2021, 23 (01) : 95 - 101
  • [24] Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis
    Mizia-Stec, Katarzyna
    Pysz, Piotr
    Jasinski, Marek
    Adamczyk, Tomasz
    Drzewiecka-Gerber, Agnieszka
    Chmiel, Artur
    Krejca, Michal
    Bochenek, Andrzej
    Wos, Stanislaw
    Sosnowski, Maciej
    Gasior, Zbigniew
    Trusz-Gluza, Maria
    Tendera, Michal
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (02) : 343 - 352
  • [25] Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis
    Katarzyna Mizia-Stec
    Piotr Pysz
    Marek Jasiński
    Tomasz Adamczyk
    Agnieszka Drzewiecka-Gerber
    Artur Chmiel
    Michał Krejca
    Andrzej Bochenek
    Stanisław Woś
    Maciej Sosnowski
    Zbigniew Gąsior
    Maria Trusz-Gluza
    Michał Tendera
    The International Journal of Cardiovascular Imaging, 2012, 28 : 343 - 352
  • [26] Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography
    Linnea Hornbech Larsen
    Klaus Fuglsang Kofoed
    Helle Gervig Carstensen
    Mads Rams Mejdahl
    Mads Jønsson Andersen
    Jesper Kjaergaard
    Olav Wendelboe Nielsen
    Lars Køber
    Rasmus Møgelvang
    Christian Hassager
    The International Journal of Cardiovascular Imaging, 2014, 30 : 165 - 173
  • [27] Quantification of aortic valve area at 256-slice computed tomography: Comparison with transesophageal echocardiography and cardiac catheterization in subjects with high-grade aortic valve stenosis prior to percutaneous valve replacement
    Klass, Oliver
    Walker, Matthew J.
    Olszewski, Mark E.
    Bahner, Johannes
    Feuerlein, Sebastian
    Hoffmann, Martin H. K.
    Lang, Alexandra
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) : 151 - 157
  • [28] Dynamic assessment of aortic annulus in patients with aortic stenosis throughout cardiac cycle with dual-source computed tomography
    Peng, Li-qing
    Yang, Zhi-gang
    Yu, Jian-qun
    Chu, Zhi-gang
    Deng, Wen
    Shao, Heng
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 158 (02) : 304 - 307
  • [29] Comparison of Aortic Annulus Diameter Measurement between Multi-Detector Computed Tomography and Echocardiography: A Meta-Analysis
    Zhang, Ruifang
    Song, Yi
    Zhou, Yuanyuan
    Sun, Lulu
    PLOS ONE, 2013, 8 (03):
  • [30] Comparison of Grading of Aortic Stenosis between Transthoracic and Transesophageal Echocardiography in Adult Patients Undergoing Elective Aortic Valve Replacement Surgeries: A Prospective Observational Study
    Nanditha, S.
    Malik, Vishwas
    Hasija, Suruchi
    Malhotra, Poonam
    Sreenivas, V.
    Chauhan, Sandeep
    ANNALS OF CARDIAC ANAESTHESIA, 2019, 22 (02) : 194 - 198