Acute Ischemic Stroke: Infarct Core Estimation on CT Angiography Source Images Depends on CT Angiography Protocol

被引:61
作者
Pulli, Benjamin [1 ]
Schaefer, Pamela W. [1 ]
Hakimelahi, Reza [1 ]
Chaudhry, Zeshan A.
Lev, Michael H. [1 ]
Hirsch, Joshua A.
Gonzalez, R. Gilberto [1 ]
Yoo, Albert J. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Neuroradiol, Boston, MA 02114 USA
基金
美国国家卫生研究院;
关键词
CEREBRAL-BLOOD-FLOW; APPARENT DIFFUSION-COEFFICIENT; POSITRON-EMISSION-TOMOGRAPHY; TISSUE-PLASMINOGEN ACTIVATOR; COMPUTED-TOMOGRAPHY; THROMBOLYSIS TRIAL; LESION VOLUME; PERFUSION; MRI; PREDICTION;
D O I
10.1148/radiol.11110896
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test whether the relationship between acute ischemic infarct size on concurrent computed tomographic (CT) angiography source images and diffusion-weighted (DW) magnetic resonance images is dependent on the parameters of CT angiography acquisition protocols. Materials and Methods: This retrospective study had institutional review board approval, and all records were HIPAA compliant. Data in 100 patients with anterior-circulation acute ischemic stroke and large vessel occlusion who underwent concurrent CT angiography and DW imaging within 9 hours of symptom onset were analyzed. Measured areas of hyperintensity at acute DW imaging were used as the standard of reference for infarct size. Information regarding lesion volumes and CT angiography protocol parameters was collected for each patient. For analysis, patients were divided into two groups on the basis of CT angiography protocol differences (patients in group 1 were imaged with the older, slower protocol). Inter-method agreement for infarct size was evaluated by using the Wilcoxon signed rank test, as well as by using Spearman correlation and Bland-Altman analysis. Multivariate analysis was performed to identify predictors of marked (>= 20%) overestimation of infarct size on CT angiography source images. Results: In group 1 (n = 35), median hypoattenuation volumes on CT angiography source images were slightly underestimated compared with DW imaging hyperintensity volumes (33.0 vs 41.6 mL, P = .01; ratio = 0.83), with high correlation (rho = 0.91). In group 2 (n = 65), median volume on CT angiography source images was much larger than that on DW images (94.8 vs 17.8 mL, P < .0001; ratio = 3.5), with poor correlation (rho = 0.49). This overestimation on CT angiography source images would have inappropriately excluded from reperfusion therapy 44.4% or 90.3% of patients eligible according to DW imaging criteria on the basis of a 100-mL absolute threshold or a 20% or greater mismatch threshold, respectively. Atrial fibrillation and shorter time from contrast material injection to image acquisition were independent predictors of marked (>= 20%) infarct size overestimation on CT angiography source images. Conclusion: CT angiography protocol changes designed to speed imaging and optimize arterial opacification are associated with significant overestimation of infarct size on CT angiography source images. (C)RSNA, 2011
引用
收藏
页码:593 / 604
页数:12
相关论文
共 56 条
  • [1] Magnetic resonance imaging profiles predict clinical response to early reperfusion: The diffusion and perfusion imaging evaluation for understanding stroke evolution (DEFUSE) study
    Albers, Gregory W.
    Thijs, Vincent N.
    Wechsle, Lawrence
    Kemp, Stephanie
    Schlaug, Gottfried
    Skalabrin, Elaine
    Bammer, Roland
    Kakuda, Wataru
    Lansberg, Maarten G.
    Shuaib, Ashfaq
    Coplin, William
    Hamilton, Scott
    Moseley, Michael
    Marks, Michael P.
    [J]. ANNALS OF NEUROLOGY, 2006, 60 (05) : 508 - 517
  • [2] [Anonymous], IM BAS THROMB TRIAL
  • [3] Bartlett ES, 2006, AM J NEURORADIOL, V27, P13
  • [4] Low Rates of Acute Recanalization With Intravenous Recombinant Tissue Plasminogen Activator in Ischemic Stroke Real-World Experience and a Call for Action
    Bhatia, Rohit
    Hill, Michael D.
    Shobha, Nandavar
    Menon, Bijoy
    Bal, Simerpreet
    Kochar, Puneet
    Watson, Tim
    Goyal, Mayank
    Demchuk, Andrew M.
    [J]. STROKE, 2010, 41 (10) : 2254 - 2258
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] DIFFUSION-WEIGHTED IMAGING STUDIES OF CEREBRAL-ISCHEMIA IN GERBILS - POTENTIAL RELEVANCE TO ENERGY FAILURE
    BUSZA, AL
    ALLEN, KL
    KING, MD
    VANBRUGGEN, N
    WILLIAMS, SR
    GADIAN, DG
    [J]. STROKE, 1992, 23 (11) : 1602 - 1612
  • [7] Acute brain infarct: Detection and delineation with CT angiographic source images versus nonenhanced CT scans
    Camargo, Erica C. S.
    Furie, Karen L.
    Singhal, Aneesh B.
    Roccatagliata, Luca
    Cunnane, Mary E.
    Halpern, Elkan F.
    Harris, Gordon J.
    Smith, Wade S.
    Gonzalez, Ramon G.
    Koroshetz, Walter J.
    Lev, Michael H.
    [J]. RADIOLOGY, 2007, 244 (02) : 541 - 548
  • [8] Early MRI findings in patients receiving tissue plasminogen activator predict outcome: Insights into the pathophysiology of acute stroke in the thrombolysis era
    Chalela, JA
    Kang, DW
    Luby, M
    Ezzeddine, M
    Latour, LL
    Todd, JW
    Dunn, B
    Warach, S
    [J]. ANNALS OF NEUROLOGY, 2004, 55 (01) : 105 - 112
  • [9] Magnetic resonance imaging and computed tomography in emergency assessment of patients with suspected acute stroke: a prospective comparison
    Chalela, Julio A.
    Kidwell, Chelsea S.
    Nentwich, Lauren M.
    Luby, Marie
    Butman, John A.
    Demchuk, Andrew M.
    Hill, Michael D.
    Patronas, Nicholas
    Latour, Lawrence
    Warach, Steven
    [J]. LANCET, 2007, 369 (9558) : 293 - 298
  • [10] Ischemic diffusion lesion reversal is uncommon and rarely alters perfusion-diffusion mismatch
    Chemmanam, T.
    Campbell, B. C. V.
    Christensen, S.
    Nagakane, Y.
    Desmond, P. M.
    Bladin, C. F.
    Parsons, M. W.
    Levi, C. R.
    Barber, P. A.
    Donnan, G. A.
    Davis, S. M.
    [J]. NEUROLOGY, 2010, 75 (12) : 1040 - 1047