共 36 条
Effectiveness of an Integrated Real-Time PCR Method for Detection of the Mycobacterium tuberculosis Complex in Smear-Negative Extrapulmonary Samples in an Area of Low Tuberculosis Prevalence
被引:77
作者:
Moure, Raquel
[1
]
Martin, Rogelio
[1
,2
]
Alcaide, Fernando
[1
,2
]
机构:
[1] IDIBELL Bellvitge Hosp, Dept Microbiol, Lhospitalet De Llobregat, Barcelona, Spain
[2] Univ Barcelona, Dept Pathol & Expt Therapeut, Lhospitalet De Llobregat, Barcelona, Spain
关键词:
XPERT MTB/RIF TEST;
PLEURAL EFFUSION;
DIAGNOSIS;
RESISTANCE;
TESTS;
D O I:
10.1128/JCM.06467-11
中图分类号:
Q93 [微生物学];
学科分类号:
071005 ;
100705 ;
摘要:
Early extrapulmonary tuberculosis (EPTB) diagnosis is particularly difficult. Among 108 smear-negative extrapulmonary samples showing a positive culture for Mycobacterium tuberculosis complex (43 body fluids and 65 nonliquid specimens), 63 (58.3%) were positive with the Xpert MTB/RIF assay (GX). GX sensitivity was quite low for samples from sterile locations (especially for pleural fluids: 26.9%) but high for some nonliquid samples, like abscess aspirates (76.5%). In summary, GX may be a useful tool to be considered for EPTB diagnosis.