Major parameters affecting the calculation of equilibrium factor using SSNTD-measured track densities

被引:14
作者
Abo-Elmagd, M [1 ]
Mansy, M [1 ]
Eissa, HM [1 ]
El-Fiki, MA [1 ]
机构
[1] Natl Inst Stand, Radiat Measurements Dept, Giza 12211, Egypt
关键词
SSNTD; diffusion chamber; F; calibration factor;
D O I
10.1016/j.radmeas.2005.06.007
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The equilibrium factor F between radon and its daughters as a function of the track density ratio D/D-0 between bare and in can track detectors is solved graphically and gave more accurate solution than that solved mathematically elsewhere. The advantages of the graphical solution come from its simplicity and does not need any tedious mathematical formula or a computer program. The simplicity of this solution makes us study many parameters that affect the equilibrium factor determination such as the detector type, the diffusion chamber dimensions, the membrane specifications and the behavior of alpha-emitters around the detector. The results show that the equilibrium factor as a function of D/D-0 takes different form according to the facility used. The range of this study covers two widely used detectors (CR-39 and LR-115) equipped in two widely used diffusion chambers (small and medium chambers). (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 13 条
[1]  
DURRANI SA, 1997, RADON MEASUREMENT ET
[2]  
FAJ Z, 1991, RADIAT PROT DOSIM, V35, P265
[3]  
FLEISCHER RL, 1988, NUCL TRACKS RAD MEAS, V14, P421
[5]   DETERMINATION OF CALIBRATION COEFFICIENT FOR RADON MEASUREMENTS USING A TRACK DETECTOR [J].
NIKEZIC, D ;
MARKOVIC, P ;
BEKUZAROV, D .
HEALTH PHYSICS, 1993, 64 (06) :628-632
[6]   Determination of deposition behaviour of 218Po from track density distribution on SSNTD in diffusion chamber [J].
Nikezic, D ;
Yu, KN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 437 (2-3) :531-537
[7]   CALCULATING THE CALIBRATION COEFFICIENT FOR RADON MEASUREMENTS WITH THE BARE LR 115-II TRACK DETECTOR [J].
NIKEZIC, D ;
MARKOVIC, P ;
UZAROV, DB .
HEALTH PHYSICS, 1992, 62 (03) :239-244
[8]   Etched track radiometers in radon measurements: a review [J].
Nikolaev, VA ;
Ilic, R .
RADIATION MEASUREMENTS, 1999, 30 (01) :1-13
[9]  
PLANINIC J, 1990, HEALTH PHYS, V59, P349
[10]   THE EQUILIBRIUM FACTOR-F BETWEEN RADON AND ITS DAUGHTERS [J].
PLANINIC, J ;
FAJ, Z .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02) :550-552