AC loss measurements in pancake coils wound with 2G tapes and Roebel cable: dependence on spacing between turns/strands

被引:29
作者
Jiang, Zhenan [1 ]
Long, N. J. [1 ]
Badcock, R. A. [1 ]
Staines, Mike [1 ]
Slade, R. A. [1 ]
Caplin, A. D. [2 ]
Amemiya, Naoyuki [3 ]
机构
[1] Ind Res Ltd, Lower Hutt 5040, New Zealand
[2] Univ London Imperial Coll Sci Technol & Med, Blackett Lab, London SW7 2BW, England
[3] Kyoto Univ, Grad Sch Engn, Nishikyo Ku, Kyoto 6158510, Japan
关键词
COATED CONDUCTORS; TRANSPORT;
D O I
10.1088/0953-2048/25/3/035002
中图分类号
O59 [应用物理学];
学科分类号
摘要
AC loss measurements in five single pancake coils wound with 4 mm wide commercial high temperature superconductor wires were carried out to investigate the dependence of coil AC loss on separation between the superconductor layers in the neighbouring coil turns (g) and coil turn number (N) for a given number of ampere-turns NI. The highest frequency was set at approximately 1 kHz. The AC losses measured at different frequencies agreed well with each other. AC loss in the coils with the same N increases with decreasing g. When g is increased to 1.5 times the tape width (6 mm), the loss level is similar to that in an isolated wire. Transport AC loss per unit length in the pancake coils increases with increasing turn number. However, when g is increased to 1.5 times the tape width, the loss level in the coils with different turn number is almost the same. This indicates that, at the same NI, a coil with greater N is advantageous, even considering the conductor length difference. Therefore to achieve a given level of NI for a coil and minimize AC loss, we should favour coils with more turns. Coil AC loss can be measured using voltage taps attached to copper blocks outside a coil with reasonable accuracy. This is important for measuring AC loss in a coil with a complicated structure where voltage taps are not able to be attached inside the coil. AC loss in a nine-turn pancake coil wound with a 5 m long 9/2 Roebel cable (i.e. with 9 mm x 2 mm width strands) was measured using voltage loops arranged in each Roebel strand in the central turn of the coil. The AC loss in the coil was compared with two straight 9/2 Roebel cables with and without spacing between the strands. The combination of inter-strand spacing and turn spacing is an effective way to reduce AC loss in a single pancake coil wound with a Roebel cable.
引用
收藏
页数:11
相关论文
共 19 条
[1]   Transport losses in single and assembled coated conductors with textured-metal substrate with reduced magnetism [J].
Amemiya, N. ;
Jiang, Z. ;
Li, Z. ;
Nakahata, M. ;
Kato, T. ;
Ueyama, M. ;
Kashima, N. ;
Nagaya, S. ;
Shiohara, S. .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (15-20) :1718-1722
[2]   Ac loss reduction of multilayer superconducting power transmission cables by using narrow coated conductors [J].
Amemiya, Naoyuki ;
Li, Quan ;
Ito, Kaoru ;
Takeuchi, Katsutoku ;
Nakamura, Taketsune ;
Okuma, Takeshi .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2011, 24 (06)
[3]   Effects of Lateral-Tailoring of Coated Conductor for Ac Loss Reduction of Superconducting Power Transmission Cables [J].
Amemiya, Naoyuki ;
Li, Quan ;
Takeuchi, Katsutoku ;
Nakamura, Taketsune ;
Yagi, Masashi ;
Mukoyama, Shinichi ;
Aoki, Yuji ;
Fujiwara, Noboru .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) :943-946
[4]   AC loss measurement of HTS coils with ferromagnetic disks [J].
Furuse, M ;
Kondoh, J ;
Tanaka, H ;
Umeda, M .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) :2356-2359
[5]   Status of high transport current ROEBEL assembled coated conductor cables [J].
Goldacker, Wilfried ;
Frank, Antje ;
Kudymow, Andrej ;
Heller, Reinhard ;
Kling, Andrea ;
Terzieva, Stanimira ;
Schmidt, Curt .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2009, 22 (03)
[6]   Measuring transport AC losses in YBCO-coated conductor coils [J].
Grilli, F. ;
Ashworth, Stephen P. .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2007, 20 (08) :794-799
[7]   Critical current density distribution and magnetization loss in YBCO coated conductors [J].
Jiang, Z. ;
Amemiya, N. ;
Maruyama, O. ;
Shiohara, Y. .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2007, 463 (790-794) :790-794
[8]   Comparison of transport AC losses in an eight-strand YBCO Roebel cable and a four-tape YBCO stack [J].
Jiang, Z. ;
Thakur, K. P. ;
Long, N. J. ;
Badcock, R. A. ;
Staines, M. .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2011, 471 (21-22) :999-1002
[9]   The dependence of AC loss characteristics on the spacing between strands in YBCO Roebel cables [J].
Jiang, Zhenan ;
Thakur, K. P. ;
Staines, Mike ;
Badcock, R. A. ;
Long, N. J. ;
Buckley, R. G. ;
Caplin, A. D. ;
Amemiya, Naoyuki .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2011, 24 (06)
[10]   Transport AC loss characteristics of a nine strand YBCO Roebel cable [J].
Jiang, Zhenan ;
Badcock, R. A. ;
Long, N. J. ;
Staines, Mike ;
Thakur, K. P. ;
Lakshmi, L. S. ;
Wright, A. ;
Hamilton, K. ;
Sidorov, G. N. ;
Buckley, R. G. ;
Amemiya, Naoyuki ;
Caplin, A. D. .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2010, 23 (02)