Improvement in image quality of computed radiography systems for mammography

被引:0
作者
Yang, Chang-Ying Joseph [1 ]
Huang, Weidong [1 ]
机构
[1] Carestream Hlth Inc, Clin Applicat Res, Rochester, NY 14615 USA
来源
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2008年 / 6913卷
关键词
computed radiography; digital mammography; image quality; modulation transfer function (MTF); detective quantum efficiency (DQE);
D O I
10.1117/12.772055
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The image quality of three experimental computed radiography (CR) mammography systems was compared through the measurement of commonly accepted image-quality metrics such as modulation transfer function (MTF) and detective quantum efficiency (DQE). The design and configuration of the scanners in the three systems were different in that they had different signal extraction strategies for each storage phosphor screen. Efforts were also made to improve the image quality through changes in phosphor layers, phosphor particle morphology, particle size distribution, and phosphor binder ratio. The effects on overall image quality as a result of these improvements were demonstrated on these systems. It was found that there were significant variations in system MTF and DQE, depending on how the CR system was configured. Higher system MTF does not always lead to higher DQE. Screen designs as well as scanning strategies need to be taken into consideration in order to achieve image quality improvements for the application of mammography.
引用
收藏
页数:7
相关论文
共 10 条
  • [1] Assessment of different computational models for generation of x-ray spectra in diagnostic radiology and mammography
    Ay, MR
    Sarkar, S
    Shahriari, M
    Sardari, D
    Zaidi, H
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1660 - 1675
  • [2] Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography
    Boone, JM
    Fewell, TR
    Jennings, RJ
    [J]. MEDICAL PHYSICS, 1997, 24 (12) : 1863 - 1874
  • [3] DQE(F) OF 4 GENERATIONS OF COMPUTED RADIOGRAPHY ACQUISITION DEVICES
    DOBBINS, JT
    ERGUN, DL
    RUTZ, L
    HINSHAW, DA
    BLUME, H
    CLARK, DC
    [J]. MEDICAL PHYSICS, 1995, 22 (10) : 1581 - 1593
  • [4] A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY
    FUJITA, H
    TSAI, DY
    ITOH, T
    DOI, K
    MORISHITA, J
    UEDA, K
    OHTSUKA, A
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) : 34 - 39
  • [5] RANDOM NOISE PRODUCED BY X-RAY FLUORESCENT SCREENS
    LUBBERTS, G
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (11) : 1475 - &
  • [6] Lubinsky A. R., 1987, Proceedings of the SPIE - The International Society for Optical Engineering, V767, P167
  • [7] Effect of depth dependent modulation transfer function and K-fluorescence reabsorption on the detective quantum efficiency of indirect conversion flat panel x-ray imaging systems using CsI
    Rowlands, JA
    Ji, WG
    Zhao, W
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 257 - 267
  • [8] CALCULATION OF MODULATION TRANSFER-FUNCTIONS OF X-RAY FLUORESCENT SCREENS
    SWANK, RK
    [J]. APPLIED OPTICS, 1973, 12 (08): : 1865 - 1870
  • [9] ABSORPTION AND NOISE IN X-RAY PHOSPHORS
    SWANK, RK
    [J]. JOURNAL OF APPLIED PHYSICS, 1973, 44 (09) : 4199 - 4203
  • [10] Noise power spectra of images from digital mammography detectors
    Williams, MB
    Mangiafico, PA
    Simoni, PU
    [J]. MEDICAL PHYSICS, 1999, 26 (07) : 1279 - 1293