Computational fluid dynamic investigation of liquid rack cooling in data centres

被引:132
|
作者
Almoli, Ali [1 ]
Thompson, Adam [1 ]
Kapur, Nikil [1 ]
Summers, Jonathan [1 ]
Thompson, Harvey [1 ]
Hannah, George [2 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Engn Thermofluids Surfaces & Interfaces iETS, Leeds LS2 9JT, W Yorkshire, England
[2] Airedale Int Air Conditioning Ltd, Leeds, W Yorkshire, England
关键词
Data centres; Liquid cooling; Heat transfer; CFD modelling;
D O I
10.1016/j.apenergy.2011.02.003
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Relying on thermal air management in a data centre is becoming less effective as heat densities from the Information Technology (IT) equipment continue to rise. Direct liquid cooling is more efficient at transferring the waste heat, but requires liquid loops passing as close as possible to the heat source. A new Computational Fluid Dynamics (CFD) strategy is developed for data centre scenarios where a liquid loop heat exchanger is attached at the rear of server racks (back doors), which can avoid the need to separate the cold and hot air streams in traditional hot/cold aisle arrangements. The effectiveness of additional fans in the back door heat exchangers is investigated using the three-dimensional CFD model of a simplified three-aisle, six-rack data centre configuration. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 50 条
  • [41] COMPUTATIONAL FLUID DYNAMICS CHARACTERIZATION OF A HYBRID COOLING SYSTEM COMPOSED OF A DISPLACEMENT VENTILATION UNIT AND A RADIANT COOLING FLOOR
    Pena-Suarez, J. M.
    Ortega-Casanova, J.
    COMPUTATIONAL THERMAL SCIENCES, 2013, 5 (02): : 127 - 141
  • [42] Computational fluid dynamic modelling of two phase flow in a hydrocyclone
    Leeuwner, M. J.
    Eksteen, J. J.
    JOURNAL OF THE SOUTHERN AFRICAN INSTITUTE OF MINING AND METALLURGY, 2008, 108 (04) : 231 - 236
  • [43] Modelling and computational fluid dynamic behaviour of a biofilter treating benzene
    Rahul
    Mathur, Anil Kumar
    Bala, Shashi
    Majumder, Chandrajitbalo
    BIORESOURCE TECHNOLOGY, 2012, 125 : 200 - 207
  • [44] Investigation of energy saving potential for data centres based on load profile
    Bi, Y.
    Zhao, X.
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON FUTURE ENERGY SYSTEMS (E-ENERGY'17), 2017, : 271 - 277
  • [45] Investigation in the Characteristics of the Personal Ventilation Using Computational Fluid Dynamics
    Mazej, Mitja
    Butala, Vincenc
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (06) : 749 - 771
  • [46] A Dynamic Control System for Server Processor Direct Liquid Cooling
    Chen, Haoran
    Han, Yong
    Tang, Gongyue
    Zhang, Xiaowu
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2020, 10 (05): : 786 - 794
  • [47] A Numerical Investigation of Transpiration Cooling with Liquid Coolant Phase Change
    Shi, J. X.
    Wang, J. H.
    TRANSPORT IN POROUS MEDIA, 2011, 87 (03) : 703 - 716
  • [48] Experimental and Numerical Investigation of Single-Phase Liquid Cooling for Heterogeneous Integration Multichip Module
    Gharaibeh, Ahmad R.
    Soud, Qusai
    Manaserh, Yaman
    Tradat, Mohammad
    Sammakia, Bahgat
    JOURNAL OF ELECTRONIC PACKAGING, 2024, 146 (04)
  • [49] Experimental investigation of an optimized indirect free cooling system including a dry cooler equipped with evaporative cooling pads for data center
    Hnayno, Mohamad
    Chehade, Ali
    Klaba, Henryk
    Polidori, Guillaume
    Maalouf, Chadi
    ENERGY REPORTS, 2023, 9 : 460 - 469
  • [50] Experimental investigation of an optimized indirect free cooling system including a dry cooler equipped with evaporative cooling pads for data center
    Hnayno, Mohamad
    Chehade, Ali
    Klaba, Henryk
    Polidori, Guillaume
    Maalouf, Chadi
    ENERGY REPORTS, 2023, 9 : 460 - 469