Comparison of Template-Matching and Singular-Spectrum-Analysis Methods for Imaging Implanted Brachytherapy Seeds

被引:3
作者
Alam, S. Kaisar [1 ]
Mamou, Jonathan [1 ]
Feleppa, Ernest J. [1 ]
Kalisz, Andrew [1 ]
Ramachandran, Sarayu [1 ]
机构
[1] Lizzi Ctr Biomed Engn, New York, NY USA
关键词
I-125 PROSTATE IMPLANTS; CT-BASED DOSIMETRY; POSTIMPLANT DOSIMETRY; ULTRASONIC-DETECTION; TRANSPERINEAL; MORBIDITY; VOLUMES; SIGNALS; IMPACT; CANCER;
D O I
10.1109/TUFFC.2011.2105
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Brachytherapy using small implanted radioactive seeds is becoming an increasingly popular method for treating prostate cancer, in which a radiation oncologist implants seeds in the prostate transperineally under ultrasound guidance. Dosimetry software determines the optimal placement of seeds for achieving the prescribed dose based on ultrasonic determination of the gland boundaries. However, because of prostate movement and distortion during the implantation procedure, some seeds may not be placed in the desired locations; this causes the delivered dose to differ from the prescribed dose. Current ultrasonic imaging methods generally cannot depict the implanted seeds accurately. We are investigating new ultrasonic imaging methods that show promise for enhancing the visibility of seeds and thereby enabling real-time detection and correction of seed-placement errors during the implantation procedure. Real-time correction of seed-placement errors will improve the therapeutic radiation dose delivered to target tissues. In this work, we compare the potential performance of a template-matching method and a previously published method based on singular spectrum analysis for imaging seeds. In particular, we evaluated how changes in seed angle and position relative to the ultrasound beam affect seed detection. The conclusion of the present study is that singular spectrum analysis has better sensitivity but template matching is more resistant to false positives; both perform well enough to make seed detection clinically feasible over a relevant range of angles and positions. Combining the information provided by the two methods may further reduce ambiguities in determining where seeds are located.
引用
收藏
页码:2484 / 2491
页数:8
相关论文
共 22 条
[1]   SHORT-TERM MORBIDITY FROM CT-PLANNED TRANSPERINEAL I-125 PROSTATE IMPLANTS [J].
ARTERBERY, VE ;
WALLNER, K ;
ROY, J ;
FUKS, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (04) :661-667
[2]  
Blasko JC, 1987, ENDOCURIETHER HYPERT, V3, P131
[3]   EXTRACTING QUALITATIVE DYNAMICS FROM EXPERIMENTAL-DATA [J].
BROOMHEAD, DS ;
KING, GP .
PHYSICA D, 1986, 20 (2-3) :217-236
[4]   Novel methods of analyzing radio-frequency echo signals for the purpose of imaging brachytherapy seeds used to treat prostate cancer [J].
Feleppa, EJ ;
Ramachandran, S ;
Alam, SK ;
Kalisz, A ;
Ketterling, JA ;
Ennis, RD ;
Wuu, CS .
MEDICAL IMAGE 2002: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2002, 4687 :127-138
[5]   TRANSPERINEAL I125 SEED IMPLANTATION IN PROSTATIC-CANCER GUIDED BY TRANS-RECTAL ULTRASONOGRAPHY [J].
HOLM, HH ;
JUUL, N ;
PEDERSEN, JF ;
HANSEN, H ;
STROYER, I .
JOURNAL OF UROLOGY, 1983, 130 (02) :283-286
[6]   TREATMENT-RELATED SYMPTOMS DURING THE 1ST YEAR FOLLOWING TRANSPERINEAL I-125 PROSTATE IMPLANTATION [J].
KLEINBERG, L ;
WALLNER, K ;
ROY, J ;
ZELEFSKY, M ;
ARTERBERY, VE ;
FUKS, Z ;
HARRISON, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04) :985-990
[7]   Angle-dependent ultrasonic detection and imaging of brachytherapy seeds using singular spectrum analysis [J].
Mamou, Jonathan ;
Ramachandran, Sarayu ;
Feleppa, Ernest J. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 123 (04) :2148-2159
[8]   Singular spectrum analysis applied to ultrasonic detection and imaging of brachytherapy seeds [J].
Mamou, Jonathan ;
Feleppa, Ernest J. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 121 (03) :1790-1801
[9]   TRANSPERINEAL PALLADIUM-103 PROSTATE BRACHYTHERAPY - ANALYSIS OF MORBIDITY AND SEED MIGRATION [J].
NAG, S ;
SCAPEROTH, DD ;
BADALAMENT, R ;
HALL, SA ;
BURGERS, J .
UROLOGY, 1995, 45 (01) :87-92
[10]   Impact of differences in ultrasound and computed tomography volumes on treatment planning of permanent prostate implants [J].
Narayana, V ;
Roberson, PL ;
Pu, AT ;
Sandler, H ;
Winfield, RH ;
McLaughlin, PW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (05) :1181-1185