Explicit Simulation of Circular CFST Stub Columns with External Steel Confinement under Axial Compression

被引:24
作者
Alatshan, Faesal [1 ,2 ]
Osman, Siti Aminah [1 ]
Mashiri, Fidelis [3 ]
Hamid, Roszilah [1 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Engn & Built Environm, Smart & Sustainable Township Res Ctr, Bangi 43600, Selangor, Malaysia
[2] Coll Engn Technol, Dept Civil Engn, Houn 61160, Libya
[3] Univ Western Sydney, Sch Comp Engn & Math, Sydney, NSW 2751, Australia
关键词
concrete filled steel tube (CFST); ring/spiral confinements; explicit simulation; stub columns; finite element analysis (FEA); axial compression; STRESS-STRAIN CURVES; TUBE COLUMNS; BOX COLUMNS; CONCRETE; BEHAVIOR; STRENGTH; PERFORMANCE; MODEL; DUCTILITY;
D O I
10.3390/ma13010023
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Concrete-filled steel tube (CFST) structural members have been widely used in engineering projects for their superior strength and ductility. However, the different lateral dilation characteristics between concrete infill and steel tube have caused imperfect composite interaction during the early loading stage. To overcome this issue, external steel confinements in the form of rings and spiral were previously suggested to minimise the lateral expansion of the steel tube and enhance the concrete confinement effects. This study presented the analytical behaviour of circular CFST short columns with an external ring or spiral confinements which are subjected to axial loading. An explicit finite element (FE) model was developed and verified based on previous experimental findings. Besides that, this study analysed the failure modes, axial load-strain relationship, stress distributions, and bond strength of the composite column components. Parametric analysis was also undertaken to evaluate the impact of material strengths, total steel ratio, and diameter-to-thickness ratio. The results suggest that the use of external steel confinement can enhance the compressive behaviour of CFSTs better than increasing the thickness of the steel tube when using the same steel ratio. Finally, simplified design formulations were developed to accurately calculate the ultimate capacity of CFST columns with and without external steel confinement.
引用
收藏
页数:24
相关论文
共 40 条
[1]  
ABAQUS Standard, 2014, USERS MANUAL
[2]   The enhanced performance of CFST beams using different strengthening schemes involving unidirectional CFRP sheets: An experimental study [J].
Al Zand, Ahmed W. ;
Badaruzzaman, Wan Hamidon W. ;
Mutalib, Azrul A. ;
Hilo, Salam J. .
ENGINEERING STRUCTURES, 2016, 128 :184-198
[3]  
Alatshan F., 2013, APPL MECH MAT
[4]  
[Anonymous], 2015, ARXIV EPRINTS ARXIV1
[5]  
[Anonymous], 2011, Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary
[6]   PERFORMANCE OF AXIALLY LOADED TAPERED CONCRETE-FILLED STEEL COMPOSITE SLENDER COLUMNS [J].
Bahrami, Alireza ;
Wan Badaruzzaman, Wan Hamidon ;
Osman, Siti Aminah .
JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2013, 19 (05) :705-717
[7]   INVESTIGATION OF CONCRETE-FILLED STEEL COMPOSITE (CFSC) STUB COLUMNS WITH BAR STIFFENERS [J].
Bahrami, Alireza ;
Badaruzzaman, Wan Hamidon Wan ;
Osman, Siti Aminah .
JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT, 2013, 19 (03) :433-446
[8]   Behaviour of stiffened concrete-filled steel composite (CFSC) stub columns [J].
Bahrami, Alireza ;
Badaruzzaman, Wan Hamidon Wan ;
Osman, Siti Aminah .
LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2013, 10 (02) :409-439
[9]  
Bahrami A, 2012, COMPUT CONCRETE, V9, P403
[10]   Axial load behavior of square CFT stub column with binding bars [J].
Cai, J ;
He, ZQ .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (05) :472-483