Assessment and minimization of contralateral breast dose for conventional and intensity modulated breast radiotherapy

被引:25
|
作者
Burmeister, Jay [1 ,2 ]
Alvarado, Nicole [1 ,2 ]
Way, Sarah [1 ,2 ]
McDermott, Patrick [1 ,2 ]
Bossenberger, Todd [1 ,2 ]
Jaenisch, Harriett [1 ,2 ]
Patel, Rajiv [1 ,2 ]
Washington, Tara [1 ,2 ]
机构
[1] Gershenson Radiat Oncol Ctr, Karmanos Canc Inst, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI USA
关键词
breast radiotherapy; breast IMRT; contralateral breast dose; contralateral breast cancer;
D O I
10.1016/j.meddos.2007.04.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Breast radiotherapy is associated with an increased risk of contralateral breast cancer (CBC) in women under age 45 at the time of treatment. This risk increases with increasing absorbed dose to the contralateral breast. The use of intensity modulated radiotherapy (IMRT) is expected to substantially reduce the dose to the contralateral breast by eliminating scattered radiation from physical beam modifiers. The absorbed dose to the contralateral breast was measured for 5 common radiotherapy techniques, including paired 15 degrees wedges, lateral 30 degrees wedge only, custom-designed physical compensators, aperture based (field-within-field) IMRT with segments chosen by the planner, and inverse planned IMRT with segments chosen by a leaf sequencing algorithm after dose volume histogram (DVH)-based fluence map optimization. Further reduction in contralateral breast dose through the use of lead shielding was also investigated. While shielding was observed to have the most profound impact on surface dose, the radiotherapy technique proved to be most important in determining internal dose. Paired wedges or compensators result in the highest contralateral breast doses (nearly 10% of the prescription dose on the media] surface), while use of IMRT or removal of the medial wedge results in significantly lower doses. Aperture-based IMRT results in the lowest internal doses, primarily due to the decrease in the number of monitor units required and the associated reduction in leakage dose. The use of aperture-based IMRT reduced the average dose to the contralateral breast by greater than 50% in comparison to wedges or compensators. Combined use of IMRT and 1/8-inch-thick lead shielding reduced the dose to the interior and surface of the contralateral breast by roughly 60% and 85%, respectively. This reduction may warrant the use of IMRT for younger patients who have a statistically significant risk of contralateral breast cancer associated with breast radiotherapy. (c) 2008 American Association of Medical Dosimetrists.
引用
收藏
页码:6 / 13
页数:8
相关论文
共 50 条
  • [41] Assessment of tissue toxicity risk in breast radiotherapy using Bayesian networks
    Ciunkiewicz, Philip
    Roumeliotis, Michael
    Stenhouse, Kailyn
    McGeachy, Philip
    Quirk, Sarah
    Grendarova, Petra
    Yanushkevich, Svetlana
    MEDICAL PHYSICS, 2022, 49 (06) : 3585 - 3596
  • [42] Low-dose aspirin use and risk of contralateral breast cancer: a Danish nationwide cohort study
    Bens, Annet
    Friis, Soren
    Dehlendorff, Christian
    Jensen, Maj-Britt
    Ejlertsen, Bent
    Kroman, Niels
    Cronin-Fenton, Deirdre
    Mellemkjaer, Lene
    PREVENTIVE MEDICINE, 2018, 116 : 186 - 193
  • [43] Surface dose measurements in and out of field: Implications for breast radiotherapy with megavoltage photon beams
    Lonski, Peta
    Ramachandran, Prabhakar
    Franich, Rick
    Kron, Tomas
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (04): : 318 - 323
  • [44] A deep learning segmentation method to assess dose to organs at risk during breast radiotherapy
    Saha, Monjoy
    Jung, Jae Won
    Lee, Sung-Woo
    Lee, Choonik
    Lee, Choonsik
    Mille, Matthew M.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [45] Validation of a new open-source method for automatic delineation and dose assessment of the heart and LADCA in breast radiotherapy with simultaneous uncertainty estimation
    Finnegan, Robert
    Laugaard Lorenzen, Ebbe
    Dowling, Jason
    Thwaites, David
    Delaney, Geoff
    Brink, Carsten
    Holloway, Lois
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (03):
  • [46] Mobile shielding evaluation on the fetal dose during a breast radiotherapy using Monte Carlo simulation
    Catusso, Leonardo
    Santos, William S.
    da Silva, Rogerio M., V
    Valenca, Joao V. B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 24 - 32
  • [47] Assessment of MRI image quality for various setup positions used in breast radiotherapy planning
    Batumalai, Vikneswary
    Liney, Gary
    Delaney, Geoff P.
    Rai, Robba
    Boxer, Miriam
    Min, Myo
    Berry, Megan
    Trang Pham
    Phan, Penny
    Choong, Callie
    Rennie, Melanie
    Chan, Christine
    Holloway, Lois
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 (01) : 57 - 60
  • [48] Adjuvant radiotherapy for primary breast cancer in BRCA1 and BRCA2 mutation carriers and risk of contralateral breast cancer with special attention to patients irradiated at younger age
    Jan C. Drooger
    Delal Akdeniz
    Jean-Philippe Pignol
    Linetta B. Koppert
    Danielle McCool
    Caroline M. Seynaeve
    Maartje J. Hooning
    Agnes Jager
    Breast Cancer Research and Treatment, 2015, 154 : 171 - 180
  • [49] Adjuvant radiotherapy for primary breast cancer in BRCA1 and BRCA2 mutation carriers and risk of contralateral breast cancer with special attention to patients irradiated at younger age
    Drooger, Jan C.
    Akdeniz, Delal
    Pignol, Jean-Philippe
    Koppert, Linetta B.
    McCool, Danielle
    Seynaeve, Caroline M.
    Hooning, Maartje J.
    Jager, Agnes
    BREAST CANCER RESEARCH AND TREATMENT, 2015, 154 (01) : 171 - 180
  • [50] Superficial doses in breast cancer radiotherapy using conventional and IMRT techniques: A film-based phantom study
    Almberg, Sigrun Saur
    Lindmo, Tore
    Frengen, Jomar
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (02) : 259 - 264