Assessment and minimization of contralateral breast dose for conventional and intensity modulated breast radiotherapy

被引:25
|
作者
Burmeister, Jay [1 ,2 ]
Alvarado, Nicole [1 ,2 ]
Way, Sarah [1 ,2 ]
McDermott, Patrick [1 ,2 ]
Bossenberger, Todd [1 ,2 ]
Jaenisch, Harriett [1 ,2 ]
Patel, Rajiv [1 ,2 ]
Washington, Tara [1 ,2 ]
机构
[1] Gershenson Radiat Oncol Ctr, Karmanos Canc Inst, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI USA
关键词
breast radiotherapy; breast IMRT; contralateral breast dose; contralateral breast cancer;
D O I
10.1016/j.meddos.2007.04.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Breast radiotherapy is associated with an increased risk of contralateral breast cancer (CBC) in women under age 45 at the time of treatment. This risk increases with increasing absorbed dose to the contralateral breast. The use of intensity modulated radiotherapy (IMRT) is expected to substantially reduce the dose to the contralateral breast by eliminating scattered radiation from physical beam modifiers. The absorbed dose to the contralateral breast was measured for 5 common radiotherapy techniques, including paired 15 degrees wedges, lateral 30 degrees wedge only, custom-designed physical compensators, aperture based (field-within-field) IMRT with segments chosen by the planner, and inverse planned IMRT with segments chosen by a leaf sequencing algorithm after dose volume histogram (DVH)-based fluence map optimization. Further reduction in contralateral breast dose through the use of lead shielding was also investigated. While shielding was observed to have the most profound impact on surface dose, the radiotherapy technique proved to be most important in determining internal dose. Paired wedges or compensators result in the highest contralateral breast doses (nearly 10% of the prescription dose on the media] surface), while use of IMRT or removal of the medial wedge results in significantly lower doses. Aperture-based IMRT results in the lowest internal doses, primarily due to the decrease in the number of monitor units required and the associated reduction in leakage dose. The use of aperture-based IMRT reduced the average dose to the contralateral breast by greater than 50% in comparison to wedges or compensators. Combined use of IMRT and 1/8-inch-thick lead shielding reduced the dose to the interior and surface of the contralateral breast by roughly 60% and 85%, respectively. This reduction may warrant the use of IMRT for younger patients who have a statistically significant risk of contralateral breast cancer associated with breast radiotherapy. (c) 2008 American Association of Medical Dosimetrists.
引用
收藏
页码:6 / 13
页数:8
相关论文
共 50 条
  • [31] Surface dose and acute skin reactions in external beam breast radiotherapy
    McDermott, Patrick N.
    MEDICAL DOSIMETRY, 2020, 45 (02) : 153 - 158
  • [32] Cardiac dose from tangential breast cancer radiotherapy in the year 2006
    Taylor, Carolyn W.
    Povall, Julfle M.
    McGale, Paul
    Nisbet, Andrew
    Dodwell, David
    Smith, Jonathan T.
    Darby, Sarah C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (02): : 501 - 507
  • [33] Dosimetric Study Comparing 3D Conformal Radiotherapy (3D-CRT), Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) in Hypofractionated One-Week Radiotherapy Regimen in Breast Cancer
    Ahmad, Aftab
    Das, Saikat
    Kharade, Vipin
    Gupta, Manish
    Pandey, V. P.
    Anju, K. V.
    Balasubramanian, Ilamparithi
    Pasricha, Rajesh K.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [34] Effect of respiratory motion on the delivery of breast radiotherapy using SMLC intensity modulation
    Liu, Qiang
    McDermott, Patrick
    Burmeister, Jay
    MEDICAL PHYSICS, 2007, 34 (01) : 347 - 351
  • [35] Dosimetric evaluation of compensation in radiotherapy of the breast: MLC intensity modulation and physical compensators
    Hansen, VN
    Evans, PM
    Shentall, GS
    Helyer, SJ
    Yarnold, JR
    Swindell, W
    RADIOTHERAPY AND ONCOLOGY, 1997, 42 (03) : 249 - 256
  • [36] Letter to the Editor concerning Tsuchiya K et al. “Dosimetric comparison between intensity-modulated radiotherapy and standard wedged tangential technique for whole-breast radiotherapy in Asian women with relatively small breast volumes”
    Maria Grazia Ruo Redda
    Silvia Maria Anglesio
    Simona Allis
    Roberta Verna
    Andrea Girardi
    Lavinia Bianco
    Edoardo Trevisiol
    Alessia Reali
    Radiological Physics and Technology, 2014, 7 (2) : 387 - 388
  • [37] Outcome of ultrasound of the mammographically normal contralateral breast in patients recalled to the screening assessment clinic
    Preet Hamilton
    Simon Lowes
    Sheetal Sharma
    Alicia Wright
    Alice Leaver
    Breast Cancer Research, 17
  • [38] Outcome of ultrasound of the mammographically normal contralateral breast in patients recalled to the screening assessment clinic
    Hamilton, Preet
    Lowes, Simon
    Sharma, Sheetal
    Wright, Alicia
    Leaver, Alice
    BREAST CANCER RESEARCH, 2015, 17
  • [39] A study on contralateral breast surface dose for various tangential field techniques and the impact of set-up error on this dose
    Prabhakar, R.
    Haresh, K. P.
    Julka, P. K.
    Ganesh, T.
    Rath, G. K.
    Joshi, R. C.
    Sasindran, M.
    Naik, K. K.
    Sridhar, P. S.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2007, 30 (01) : 42 - 45
  • [40] A study on contralateral breast surface dose for various tangential field techniques and the impact of set-up error on this dose
    R. Prabhakar
    K. P. Haresh
    P. K. Julka
    T. Ganesh
    G. K. Rath
    R. C. Joshi
    M. Sasindran
    K. K. Naik
    P. S. Sridhar
    Australasian Physics & Engineering Sciences in Medicine, 2007, 30 : 42 - 45