Assessment and minimization of contralateral breast dose for conventional and intensity modulated breast radiotherapy

被引:25
|
作者
Burmeister, Jay [1 ,2 ]
Alvarado, Nicole [1 ,2 ]
Way, Sarah [1 ,2 ]
McDermott, Patrick [1 ,2 ]
Bossenberger, Todd [1 ,2 ]
Jaenisch, Harriett [1 ,2 ]
Patel, Rajiv [1 ,2 ]
Washington, Tara [1 ,2 ]
机构
[1] Gershenson Radiat Oncol Ctr, Karmanos Canc Inst, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI USA
关键词
breast radiotherapy; breast IMRT; contralateral breast dose; contralateral breast cancer;
D O I
10.1016/j.meddos.2007.04.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Breast radiotherapy is associated with an increased risk of contralateral breast cancer (CBC) in women under age 45 at the time of treatment. This risk increases with increasing absorbed dose to the contralateral breast. The use of intensity modulated radiotherapy (IMRT) is expected to substantially reduce the dose to the contralateral breast by eliminating scattered radiation from physical beam modifiers. The absorbed dose to the contralateral breast was measured for 5 common radiotherapy techniques, including paired 15 degrees wedges, lateral 30 degrees wedge only, custom-designed physical compensators, aperture based (field-within-field) IMRT with segments chosen by the planner, and inverse planned IMRT with segments chosen by a leaf sequencing algorithm after dose volume histogram (DVH)-based fluence map optimization. Further reduction in contralateral breast dose through the use of lead shielding was also investigated. While shielding was observed to have the most profound impact on surface dose, the radiotherapy technique proved to be most important in determining internal dose. Paired wedges or compensators result in the highest contralateral breast doses (nearly 10% of the prescription dose on the media] surface), while use of IMRT or removal of the medial wedge results in significantly lower doses. Aperture-based IMRT results in the lowest internal doses, primarily due to the decrease in the number of monitor units required and the associated reduction in leakage dose. The use of aperture-based IMRT reduced the average dose to the contralateral breast by greater than 50% in comparison to wedges or compensators. Combined use of IMRT and 1/8-inch-thick lead shielding reduced the dose to the interior and surface of the contralateral breast by roughly 60% and 85%, respectively. This reduction may warrant the use of IMRT for younger patients who have a statistically significant risk of contralateral breast cancer associated with breast radiotherapy. (c) 2008 American Association of Medical Dosimetrists.
引用
收藏
页码:6 / 13
页数:8
相关论文
共 50 条
  • [1] Intensity modulated radiation therapy (IMRT) reduces the dose to the contralateral breast when compared to conventional tangential fields for primary breast irradiation
    Ajay K. Bhatnagar
    Edward Brandner
    Deborah Sonnik
    Andrew Wu
    Shalom Kalnicki
    Melvin Deutsch
    Dwight E. Heron
    Breast Cancer Research and Treatment, 2006, 96 : 41 - 46
  • [2] Intensity modulated radiation therapy (IMRT) reduces the dose to the contralateral breast when compared to conventional tangential fields for primary breast irradiation
    Bhatnagar, AK
    Brandner, E
    Sonnik, D
    Wu, A
    Kalnicki, S
    Deutsch, M
    Heron, DE
    BREAST CANCER RESEARCH AND TREATMENT, 2006, 96 (01) : 41 - 46
  • [3] The Cambridge breast intensity modulated radiotherapy trial
    CE Coles
    JS Wilkinson
    AM Moody
    ACF Hoole
    N Twyman
    NG Burnet
    Breast Cancer Research, 8
  • [4] Intensity-modulated radiation therapy (IMRT) reduces the dose to the contralateral breast when compared to conventional tangential fields for primary breast irradiation: Initial report
    Bhatnagar, AK
    Brandner, E
    Sonnik, D
    Wu, A
    Kalnicki, S
    Deutsch, M
    Heron, DE
    CANCER JOURNAL, 2004, 10 (06): : 381 - 385
  • [5] The Cambridge breast intensity modulated radiotherapy trial
    Coles, C. E.
    Wilkinson, J. S.
    Moody, A. M.
    Twyman, N.
    Burnet, N. G.
    BREAST CANCER RESEARCH, 2006, 8 (Suppl 2) : S16 - S16
  • [6] Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?
    Batumalai, Vikneswary
    Quinn, Alexandra
    Jameson, Michael
    Delaney, Geoff
    Holloway, Lois
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (01) : 32 - 39
  • [7] Does breast size affect the scatter dose to the ipsilateral lung, heart, or contralateral breast in primary breast irradiation using intensity-modulated radiation therapy (IMRT)?
    Bhatnagar, AK
    Heron, DE
    Deutsch, M
    Brandner, E
    Wu, A
    Kalnicki, S
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2006, 29 (01): : 80 - 84
  • [8] Optimized dose coverage of regional lymph nodes in breast cancer: The role of intensity-modulated radiotherapy
    Dogan, Nesrin
    Cuttino, Laurie
    Lloyd, Rick
    Bump, Edward A.
    Arthur, Douglas W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1238 - 1250
  • [9] Dosimetric evaluation of irregular surface compensator and intensity-modulated radiotherapy in breast radiotherapy
    Inan, Gokcen
    Gul, Osman Vefa
    Basaran, Hamit
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2021, 26 (06) : 984 - 989
  • [10] The delivery of intensity modulated radiotherapy to the breast using multiple static fields
    Evans, PM
    Donovan, EM
    Partridge, M
    Childs, PJ
    Convery, DJ
    Eagle, S
    Hansen, VN
    Suter, BL
    Yarnold, JR
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (01) : 79 - 89