Modified Technique of Percutaneous Posterior Columnar Screw Insertion and Neutralization Plate for Complex Acetabular Fractures

被引:15
|
作者
Yu, Yi-Hsun
Tseng, I-Chuan
Su, Chun-Yi [1 ]
Huang, Jau-Wen
Wu, Chi-Chung
机构
[1] Chang Gung Mem Hosp, Dept Orthoped Surg, Div Traumatol, Tao Yuan, Taiwan
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2011年 / 71卷 / 01期
关键词
Acetabulum; Percutaneous; Kocher-Langenbeck approach; PELVIC RING DISRUPTIONS; OPERATIVE TREATMENT; RADIATION EXPOSURE; OPEN REDUCTION; FIXATION; ANTERIOR; CLASSIFICATION;
D O I
10.1097/TA.0b013e3181f2d50f
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: To overcome the complexity of acetabular fractures, several techniques, such as extensive surgical exposure, transtrochanteric osteotomy, and columnar screw fixation, were reported. However, all these techniques have their disadvantages and limitations. We report the surgical results of a modified technique with posterior columnar screw insertion and neutralization plate in a single Kocher-Langenbeck approach for complex acetabular fractures. Methods: We identified 30 patients with 30 acetabular fractures who had been treated by this technique between 1995 and 2004. Demographic data, perioperative results, and complications were all recorded. The detail of surgical procedure was described and illustrated. Results: There were 13 men and 17 women with mean age of 36.4 years (range, 19-66 years). Mean follow-up duration was 49.2 months (range, 24-112 months). All fractures achieved union, and there was no loss reduction and fixation during the follow-up period. There were five complications during hospital stay, including superficial and deep infection and transient sciatic nerve palsy. There was no loss of reduction during follow-up period. Five patients underwent total hip arthroplasty caused by posttraumatic osteoarthritis and preexisting osteoarthritis. The mean Harris Hip Score at 24-month follow-up was 79.7 (median, 92; range, 33-99). Conclusion: This study provided a modified surgical technique of percutaneous insertion of posterior columnar screw that appeared to be safe and reliably hold the column in place for healing.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [31] A new internal fixation technique for acetabular fractures involving the quadrilateral plate
    Zha, Guo-Chun
    Tulumuhan, Du-Man
    Wang, Tao
    Wan, Guo-Yang
    Wang, Yong
    Sun, Jun-Ying
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2020, 106 (05) : 855 - 861
  • [32] Percutaneous Titanium Elastic Nail Stabilization for Pelvic and Acetabular Fractures: Surgical Technique and Case Series
    Murphy, Nicholas J.
    Graan, David
    Balogh, Zsolt J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (11) : e371 - e378
  • [33] Modified Polymethylmethacrylate Cervical Plate and Screw Augmentation Technique for Intraoperative Screw Loosening
    Jo, Jae-Young
    Kang, Suk-Hyung
    Park, Seung Won
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (04): : 235 - 239
  • [34] Experimental study on treatment of acetabular anterior column fractures: applyment of a minimally invasive percutaneous lag screw guide apparatus
    Zhang, Li-hai
    Zhang, Li-cheng
    Si, Qing-hua
    Gao, Yuan
    Su, Xiu-yun
    Zhao, Zhe
    Tang, Pei-fu
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [35] 3D simulation of percutaneous sustentaculum tali screw insertion in calcaneal fractures
    Li, Xian
    Wang, Xiao-ke
    Yu, Lian-kui
    Zhang, Chao
    Zhao, Ming-ming
    Yan, Jun
    Han, Li-ren
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [36] Experimental study on the biomechanical stability of complex acetabular fractures in the quadrilateral area: application of a dynamic anterior titanium-plate screw system
    Wu, Yong-De
    Mei, Xian-Zhong
    Wu, Wei-Fei
    Zhang, Hong-Xi
    Liang, Jie
    Cai, Xian-Hua
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [37] Establishment of fluoroscopy views and standardized procedure of percutaneous magic screw insertion for acetabulum fractures
    Li, Jiantao
    Li, Zhirui
    Wang, Xiang
    Zhang, Gongzi
    Peng, Ye
    Zhang, Shuwei
    Tang, Peifu
    Zhang, Lihai
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [38] Marginal impaction in complex posterior wall acetabular fractures: role of allograft and mid-term results
    Perumal, Ramesh
    Valleri, Durga Prasad
    Gessesse, Milkias Tsehaye
    Jayaramaraju, Dheenadhayalan
    Rajasekaran, Shanmuganathan
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (03) : 435 - 440
  • [39] Using calcaneal plates in fixation of comminuted posterior wall acetabular fractures with cranial or posterior extension: a prospective case series and novel technique
    Fahmy, Mahmoud
    Yasin, Ebeed
    Abdelmoneim, Mohamed
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (7) : 3591 - 3597
  • [40] Minimally invasive posteromedial percutaneous plate osteosynthesis for diaphyseal tibial fractures: technique description
    Wajnsztejn, Andre
    Santos Pires, Robinson Esteves
    Godoy dos Santos, Alexandre Leme
    Labronici, Pedro Jose
    Alvachian Fernandes, Helio Jorge
    Ferretti, Mario
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 : S6 - S9