Development of an amplified nanostructured electrochemical sensor for the detection of cefixime in pharmaceuticals and biological samples

被引:11
作者
Darabi, Rozhin [1 ,2 ]
Shabani-Nooshabadi, Mehdi [1 ,2 ]
机构
[1] Univ Kashan, Inst Nano Sci & Nano Technol, Kashan, Iran
[2] Univ Kashan, Fac Chem, Dept Analyt Chem, Kashan, Iran
关键词
Electrochemical sensor; Cefixime; Mefenamic acid; Acetaminophen; Biological samples; GLASSY-CARBON ELECTRODE; REDUCED GRAPHENE OXIDE; VOLTAMMETRIC DETERMINATION; SPECTROFLUOROMETRIC METHOD; SENSITIVE DETERMINATION; MEFENAMIC-ACID; NANOPARTICLES; NANOTUBES; FORMULATIONS; BEHAVIOR;
D O I
10.1016/j.jpba.2022.114657
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As one of the third generation of cephalosporin category, cefixime has a considerable activity towards both gram-positive and gram-negative bacteria so the quantitative analysis is considerable. Based on the synthesized reduced graphene oxide/CoFe2O4/ionic liquid (IL) (1-Ethyl-3-Methylimidazolium) (IL/CoFe2O4/rGO) nanocomposite, a modified carbon paste electrode (CPE) was selected as a sensor for determining cefixime. The structure and ability of nanostructures are investigated by various techniques containing scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), differential pulse voltammetry (DPV), cyclic voltammetry (CV) and chronoamperometry (CHA). The suggested sensor was successfully used for the simultaneous determination of cefixime, mefenamic acid, and acetaminophen. Under optimized settings, the oxidation peak current was obtained in the two linear ranges from 0.06 to 10 mu M (0.02-4.53 mu g.ml(-1)) (R-2 = 0.9909) and 10.0-700.0 mu M (4.53-317.394 mu g.ml(-1)) (R-2 = 0.9970) along with the detection limit of cefixime 0.035 mu M (0.015 mu g.ml(-1)). The values of electro-transfer coefficient (alpha) and diffusion coefficient (D) were achieved 0.9 and 1.17 x 10(-6) cm(2)s(-1). The electro-oxidation of cefixime occurs at an approximate potential of 0.85 V with an irreversible oxidation peak. The F-test (precision) and t-test (accuracy) were used for comparing the obtained results in urine samples. The proposed modified electrode shows high performance for the analysis of cefixime, mefenamic acid, and acetaminophen in pharmaceuticals and biological samples with good results.
引用
收藏
页数:9
相关论文
共 34 条
[1]   Simultaneous determination of nine β-lactam antibiotics in human plasma by an ultrafast hydrophilic-interaction chromatography-tandem mass spectrometry [J].
Abdulla, Alan ;
Bahmany, Soma ;
Wijma, Rixt A. ;
van der Nagel, Bart C. H. ;
Koch, Birgit C. P. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1060 :138-143
[2]   Gold nanoparticles modified carbon paste electrode as an efficient electrochemical sensor for rapid and sensitive determination of cefixime in urine and pharmaceutical samples [J].
Afkhami, Abbas ;
Soltani-Felehgari, Farzaneh ;
Madrakian, Tayyebeh .
ELECTROCHIMICA ACTA, 2013, 103 :125-133
[3]   Fabrication of a new electrocatalytic sensor for determination of diclofenac, morphine and mefenamic acid using synergic effect of NiO-SWCNT and 2, 4-dimethyl-N/[1-(2, 3-dihydroxy phenyl) methylidene] aniline [J].
Akbarian, Yousef ;
Shabani-Nooshabadi, Mehdi ;
Karimi-Maleh, Hassan .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 :228-233
[4]   Spectrophotometric determination of selected cephalosporins in drug formulations using flow injection analysis [J].
Al-Momani, IF .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (5-6) :751-757
[5]   Cobalt ferrite supported on reduced graphene oxide as a T2 contrast agent for magnetic resonance imaging [J].
Alazmi, Amira ;
Singaravelu, Venkatesh ;
Batra, Nitin M. ;
Smajic, Jasmin ;
Alyami, Mram ;
Khashab, Niveen M. ;
Costa, Pedro M. F. J. .
RSC ADVANCES, 2019, 9 (11) :6299-6309
[6]   Rapid and simultaneous determination of tetracycline and cefixime antibiotics by mean of gold nanoparticles-screen printed gold electrode and chemometrics tools [J].
Asadollahi-Baboli, M. ;
Mani-Varnosfaderani, A. .
MEASUREMENT, 2014, 47 :145-149
[7]  
Azmi S.N.H., 2014, INT J CHEM NUCL META, V8, P561
[8]   A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotube/Chitosan Composite as a New Sensor for Simultaneous Determination of Acetaminophen and Mefenamic Acid in Pharmaceutical Preparations and Biological Samples [J].
Babaei, Ali ;
Afrasiabi, Mohammad ;
Babazadeh, Mitra .
ELECTROANALYSIS, 2010, 22 (15) :1743-1749
[9]  
Balooei M, 2017, ANAL BIOANAL ELECTRO, V9, P266
[10]  
Danafar H., 2015, PHARM BIOMED RES, V1, P29, DOI [DOI 10.18869/ACADPUB.PBR.1.4.29, 10.18869/acadpub.pbr.1.4.29]