Three-dimensional image cytometer based on a high-speed two-photon scanning microscope

被引:0
|
作者
Kim, KH [1 ]
Stitt, MS [1 ]
Hendricks, CA [1 ]
Almeida, KH [1 ]
Engelward, BP [1 ]
So, PTC [1 ]
机构
[1] MIT, Cambridge, MA 02139 USA
关键词
two-photon scanning microscopy; cytometry; genetic instability; mitotic recombination;
D O I
10.1117/12.424559
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a 3-D image cytometer based on two-photon scanning microscopy. The system keeps the inherent advantages from two-photon scanning microscopy: (1) The ability of imaging thick tissue samples up to a few hundred micrometers, (2) The ability to study tissue structures with subcellular resolution, (3) The ability to monitor tissue biochemistry and metabolism, and (4) The reduction of specimen photobleaching and photodamage. Therefore, 3-D image cytometer has the ability to characterize multiple cell layer specimens, in contrast with 2-D image cytometer where only single cell, layer samples can be imaged. 3-D image cytometry increases its frame rate by adapting a polygonal mirror scanner and highspeed photomultiplier tubes. The current frame rate is 13 frames per second. High throughput rate is achieved by imaging multiple cell layer specimens in 3-D at a high frame rate. The throughput rate of this system is dependent on the choice of objective lenses, specimen properties, and the speed of computer-controlled specimen stage. It can be up to approximately 100 cells per second which is comparable with that of 2-D image cytometers. With the high throughput rate and deep tissue imaging capability, 3-D image cytometer has the potential for the detection of rare cellular events inside living, intact tissues. A promising application of this 3-D image cytometer is the study of mitotic recombination in tissues. Mitotic recombination is a mechanism for genetic change. Therefore it is one of causes for carcinogenesis. However, the study of this process is difficult because recombination event is rare and it occurs at a rate of one cell in 10(5) cells. The new method for the study is (1) to engineer transgenic mice whose cells will express fluorescence in the presence of mitotic recombination, (2) to detect cells which have undergone mitotic recombination with 3-D image cytometry. The estimated time required to quantify spontaneous recombination rate is approximately within a few hours in the case that the mutation occurs at a rate of 1/10(5). The ability of this 3-D image cytometer to resolve tissue structures at video rate was demonstrated in the study of ex vivo human skin dermal structure. 25 x 25 section images were taken by shifting the acquisition region with computer-controlled specimen stage. Wide area images were reconstructed by combining each image sections. The size of complete wide area images is approximately 25 mm x 25 mm. We further performed experiments to verify this cytometer's ability for population statistics measurement. We prepared cell cultures containing a mixture of cells expressing cyan and yellow fluorescent proteins. These cell cultures with mixing ratio ranging from 1/10 up to 1/10(5) were imaged. Experimental results show that the presence of a few rare cells in large pool of the other cells can be quantitatively measured. We also imaged a punched ear specimen from a transgenic mouse which carries green fluorescent protein The data demonstatrates that this system can resolve a single green fluorescent cells in the tissue.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 50 条
  • [21] Two-photon readout of three-dimensional memory in silica
    Watanabe, M
    Juodkazis, S
    Sun, HB
    Matsuo, S
    Misawa, H
    APPLIED PHYSICS LETTERS, 2000, 77 (01) : 13 - 15
  • [22] Three-dimensional microfabrication with two-photon absorbed photopolymerization
    Maruo, S
    Nakamura, O
    Kawata, S
    17TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR SCIENCE AND NEW TECHNOLOGY, PTS 1 AND 2, 1996, 2778 : 165 - 166
  • [23] Three-dimensional microstructuring of PDMS by two-photon microstereolithography
    Hasegawa, Takuya
    Oishi, Kosuke
    Maruo, Shoji
    2006 IEEE INTERNATIONAL SYMPOSIUM ON MICRO-NANOMECHATRONICS AND HUMAN SCIENCE, 2006, : 158 - +
  • [24] Random access three-dimensional two-photon microscopy
    Rozsa, Balazs
    Katona, Gergely
    Vizi, E. Sylvester
    Varallyay, Zoltan
    Saghy, Attila
    Valenta, Laslo
    Maak, Pal
    Fekete, Julia
    Banyasz, Akos
    Szipocs, Robert
    APPLIED OPTICS, 2007, 46 (10) : 1860 - 1865
  • [25] Three-dimensional two-photon imaging in polymeric materials
    Belfield, KD
    Schafer, KJ
    Andrasik, S
    Yavuz, O
    Van Stryland, EW
    Hagan, DJ
    Hales, JM
    PHOTOREFRACTIVE FIBER AND CRYSTAL DEVICES: MATERIALS, OPTICAL PROPERTIES, AND APPLICATIONS VII, AND OPTICAL DATA STORAGE, 2002, 4459 : 281 - 289
  • [26] Two-Photon Three-Dimensional Optical Storage Memory
    Dvornikov, A. S.
    Walker, E. P.
    Rentzepis, P. M.
    JOURNAL OF PHYSICAL CHEMISTRY A, 2009, 113 (49): : 13633 - 13644
  • [27] Three-dimensional microfabrication using two-photon polymerization
    Cumpston, BH
    Ehrlich, JE
    Kuebler, SM
    Lipson, M
    Marder, SR
    McCord-Maughon, D
    Perry, JW
    Rockel, H
    Rumi, M
    MATERIALS AND DEVICE CHARACTERIZATION IN MICROMACHINING, 1998, 3512 : 168 - 168
  • [28] Evaluation of resonant scanning as a high-speed imaging technique for two-photon imaging of cortical vasculature
    Zhou, Annie
    Tomar, Alankrit
    Hassan, Ahmed M.
    Dunn, Andrew K.
    Engelmann, Shaun A.
    Mihelic, Samuel A.
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (03): : 1374 - 1385
  • [29] High-sensitivity two-photon photoacid generator for three-dimensional microfabrication
    Kuebler, SM
    Braun, KL
    Zhou, WH
    Yu, TY
    Cammack, JK
    Ober, CK
    Marder, SR
    Perry, JW
    NANOSCALE OPTICS AND APPLICATIONS, 2002, 4809 : 170 - 178
  • [30] High-sensitivity material systems for two-photon three-dimensional microfabrication
    Kuebler, SM
    Perry, JW
    Marder, SR
    Ober, CK
    Braun, KL
    Yu, TY
    Zhou, WH
    MICROMACHINING TECHNOLOGY FOR MICRO-OPTICS AND NANO-OPTICS II, 2004, 5347 : 111 - 117