Analytical method for the biomonitoring of bisphenols and parabens by liquid chromatography coupled to tandem mass spectrometry in human hair

被引:15
|
作者
Robin, Julien [1 ,2 ,3 ]
Binson, Guillaume [1 ,2 ,3 ]
Albouy, Marion [1 ,2 ,3 ]
Sauvaget, Alexis [1 ,2 ,3 ]
Pierre-Eugene, Pascale [1 ,3 ]
Migeot, Virginie [1 ,2 ,3 ]
Dupuis, Antoine [1 ,2 ,3 ]
Venisse, Nicolas [1 ,2 ]
机构
[1] Univ Poitiers, CHU Poitiers, CNRS 7267 EBI, INSERM CIC 1402, F-86000 Poitiers, France
[2] CHU Poitiers, Sante Publ, Pole Biol Pharm, 2 Rue Miletrie, F-86021 Poitiers, France
[3] Univ Poitiers, Fac Med & Pharm, TSA 51115, F-86073 Poitiers, France
关键词
Biomonitoring; Bisphenols; Parabens; Hair; OF-THE-ART; CHLORINATED DERIVATIVES; FLAME RETARDANTS; EXPOSURE; ASSOCIATION; SAMPLES;
D O I
10.1016/j.ecoenv.2022.113986
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bisphenols and parabens are endocrine disruptors families widely used in daily life. They are known to be linked to numerous pathologies such as reproductive disorders, obesity, breast cancer, hypertension and asthma. Bio-monitoring is an essential tool for assessing population exposure to environmental pollutants. Blood and urine are the main matrices used in human biomonitoring. However, they are not suitable to evaluate long-term exposure to endocrine disruptors with a short elimination half-life such as parabens or phenols. Hair appears to be an interesting alternative matrix allowing a wide window of exposure due to an accumulation of xeno-biotics during hair growth. This study presents the development and validation of a high-performance liquid chromatography coupled to tandem mass spectrometry for the simultaneous determination of bisphenol A, its chlorinated derivatives, bisphenol F, bisphenol S and parabens in human hair. An optimised sample preparation based on acidic hydrolysis followed by liquid-liquid extraction was performed, before an analysis by ultra-high performance liquid chromatography coupled to tandem mass spectrometry in multiple reaction monitoring mode. To validate the method, recognized bioanalytical guidelines were used and calibration and quality control samples were prepared in human hair samples. Linearities were over 0.996 in the whole range of concentrations. Trueness and precision were demonstrated for each target analyte with intra-day and inter-day bias values ranging from 86 % to 118 % and relative standard deviation values ranging from 0 % to 19 %. At the same time, limits of quantification were set at 0.25 ng/g for bisphenol A and parabens, 0.05 ng/g for bisphenols F and S and 0.00625 ng/g for the chlorinated derivatives of bisphenol A. This reliable method was applied to hair samples taken from hospital professionals and allowed the quantification of these endocrine disruptors in this population. Chlorinated derivatives of bisphenol A were quantified here in hair for the first time.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Multi-class method for biomonitoring of hair samples using gas chromatography-mass spectrometry
    Martin, Julia
    Moeder, Monika
    Gaudl, Alexander
    Alonso, Esteban
    Reemtsma, Thorsten
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (29) : 8725 - 8734
  • [42] Sensitive determination of pethidine and its metabolite in human hair by liquid chromatography-tandem mass spectrometry
    Jamey, Carole
    Ludes, Bertrand
    Raul, Jean-Sebastien
    TOXICOLOGIE ANALYTIQUE ET CLINIQUE, 2014, 26 (03) : 165 - 168
  • [43] Determination of ethyl glucuronide in human hair by hydrophilic interaction liquid chromatography-tandem mass spectrometry
    Yaldiz, Fadile
    Daglioglu, Nebile
    Hilal, Ahmet
    Keten, Alper
    Gulmen, Mete Korkut
    JOURNAL OF FORENSIC AND LEGAL MEDICINE, 2013, 20 (07) : 799 - 802
  • [44] A high-throughput screening method of bisphenols, bisphenols digycidyl ethers and their derivatives in dairy products by ultra-high performance liquid chromatography-tandem mass spectrometry
    Cheng, Yan
    Nie, Xue-mei
    Wu, Han-qiu
    Hong, Yun-he
    Yang, Bing-cheng
    Liu, Tong
    Zhao, Dan
    Wang, Jian-feng
    Yao, Gui-hong
    Zhang, Feng
    ANALYTICA CHIMICA ACTA, 2017, 950 : 98 - 107
  • [45] The dose effect of dansyl chloride on the derivative products of bisphenols and its application for the determination of bisphenols in human serum by high-performance liquid chromatography-tandem mass spectrometry
    Guo, Cuicui
    Zhao, Xueqin
    Jin, Jing
    Wang, Longxing
    Tan, Dongqin
    Chen, Jiping
    Ni, Yuwen
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (16) : 3052 - 3060
  • [46] Simultaneous determination of urinary parabens, bisphenol A, triclosan, and 8-hydroxy-2'-deoxyguanosine by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Ren, Lu
    Fang, Jianzhang
    Liu, Guihua
    Zhang, Jianqing
    Zhu, Zhou
    Liu, Honghe
    Lin, Kai
    Zhang, Huimin
    Lu, Shaoyou
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (10) : 2621 - 2629
  • [47] Development and validation of a green analytical method for determining fourteen bisphenols in bee pollen by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Ares, Ana M.
    Alcaide, Lucia
    Bernal, Jose
    Valverde, Silvia
    FOOD RESEARCH INTERNATIONAL, 2024, 195
  • [48] Improved quantitative method for fludarabine in human plasma by liquid chromatography and tandem mass spectrometry
    Ng, Ella S. M.
    Kangarloo, S. Bill
    Daly, Andrew
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 103 - 110
  • [49] Analysis of Perchlorate in Human Saliva by Liquid Chromatography-Tandem Mass Spectrometry
    Oldi, John F.
    Kannan, Kurunthachalam
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (01) : 142 - 147
  • [50] Assessment of parabens and ultraviolet filters in human placenta tissue by ultrasound-assisted extraction and ultra-high performance liquid chromatography-tandem mass spectrometry
    Vela-Soria, F.
    Gallardo-Torres, M. E.
    Ballesteros, O.
    Diaz, C.
    Perez, J.
    Navalon, A.
    Fernandez, M. F.
    Olea, N.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1487 : 153 - 161