Analytical method for the biomonitoring of bisphenols and parabens by liquid chromatography coupled to tandem mass spectrometry in human hair

被引:15
|
作者
Robin, Julien [1 ,2 ,3 ]
Binson, Guillaume [1 ,2 ,3 ]
Albouy, Marion [1 ,2 ,3 ]
Sauvaget, Alexis [1 ,2 ,3 ]
Pierre-Eugene, Pascale [1 ,3 ]
Migeot, Virginie [1 ,2 ,3 ]
Dupuis, Antoine [1 ,2 ,3 ]
Venisse, Nicolas [1 ,2 ]
机构
[1] Univ Poitiers, CHU Poitiers, CNRS 7267 EBI, INSERM CIC 1402, F-86000 Poitiers, France
[2] CHU Poitiers, Sante Publ, Pole Biol Pharm, 2 Rue Miletrie, F-86021 Poitiers, France
[3] Univ Poitiers, Fac Med & Pharm, TSA 51115, F-86073 Poitiers, France
关键词
Biomonitoring; Bisphenols; Parabens; Hair; OF-THE-ART; CHLORINATED DERIVATIVES; FLAME RETARDANTS; EXPOSURE; ASSOCIATION; SAMPLES;
D O I
10.1016/j.ecoenv.2022.113986
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bisphenols and parabens are endocrine disruptors families widely used in daily life. They are known to be linked to numerous pathologies such as reproductive disorders, obesity, breast cancer, hypertension and asthma. Bio-monitoring is an essential tool for assessing population exposure to environmental pollutants. Blood and urine are the main matrices used in human biomonitoring. However, they are not suitable to evaluate long-term exposure to endocrine disruptors with a short elimination half-life such as parabens or phenols. Hair appears to be an interesting alternative matrix allowing a wide window of exposure due to an accumulation of xeno-biotics during hair growth. This study presents the development and validation of a high-performance liquid chromatography coupled to tandem mass spectrometry for the simultaneous determination of bisphenol A, its chlorinated derivatives, bisphenol F, bisphenol S and parabens in human hair. An optimised sample preparation based on acidic hydrolysis followed by liquid-liquid extraction was performed, before an analysis by ultra-high performance liquid chromatography coupled to tandem mass spectrometry in multiple reaction monitoring mode. To validate the method, recognized bioanalytical guidelines were used and calibration and quality control samples were prepared in human hair samples. Linearities were over 0.996 in the whole range of concentrations. Trueness and precision were demonstrated for each target analyte with intra-day and inter-day bias values ranging from 86 % to 118 % and relative standard deviation values ranging from 0 % to 19 %. At the same time, limits of quantification were set at 0.25 ng/g for bisphenol A and parabens, 0.05 ng/g for bisphenols F and S and 0.00625 ng/g for the chlorinated derivatives of bisphenol A. This reliable method was applied to hair samples taken from hospital professionals and allowed the quantification of these endocrine disruptors in this population. Chlorinated derivatives of bisphenol A were quantified here in hair for the first time.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Analytical method for biomonitoring of endocrine-disrupting compounds (bisphenol A, parabens, perfluoroalkyl compounds and a brominated flame retardant) in human hair by liquid chromatography-tandem mass spectrometry
    Martin, Julia
    Luis Santos, Juan
    Aparicio, Irene
    Alonso, Esteban
    ANALYTICA CHIMICA ACTA, 2016, 945 : 95 - 101
  • [2] A liquid chromatography tandem mass spectrometry method to assess 41 pesticides in human hair
    Polledri, Elisa
    Mercadante, Rosa
    Fustinoni, Silvia
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [3] Analysis of four parabens and bisphenols A, F, S in urine, using dilute and shoot and liquid chromatography coupled to mass spectrometry
    Sanchis, Yovana
    Coscolla, Clara
    Yusa, Vicent
    TALANTA, 2019, 202 : 42 - 50
  • [4] Determination of parabens in human urine by liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Lu, Shaoyou
    Gong, Shihan
    Ma, Shengtao
    Zeng, Xiangying
    Yu, Zhiqiang
    Sheng, Guoying
    Fu, Jiamo
    ANALYTICAL METHODS, 2014, 6 (15) : 5566 - 5572
  • [5] Determination of four parabens and bisphenols A, F and S in human breast milk using QuEChERS and liquid chromatography coupled to mass spectrometry
    Dualde, Pablo
    Pardo, Olga
    Fernandez, Sandra F.
    Pastor, Agustin
    Yusa, Vicent
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1114 : 154 - 166
  • [6] Determination of bisphenols, parabens, and benzophenones in placenta by dispersive liquid-liquid microextraction and gas chromatography-tandem mass spectrometry
    Fernandez, M. F.
    Mustieles, V
    Suarez, B.
    Reina-Perez, I
    Olivas-Martinez, A.
    Vela-Soria, F.
    CHEMOSPHERE, 2021, 274 (274)
  • [7] Fast and eco-friendly analytical method to determine bisphenols, parabens, benzophenone-3 and triclosan in human urine by ultra-performance liquid chromatography coupled to mass spectrometry
    Peris-Camarasa, Borja
    Dualde, Pablo
    Coscolla, Clara
    MICROCHEMICAL JOURNAL, 2024, 203
  • [8] A protocol based on solid phase microextraction-gas chromatography-tandem mass spectrometry for the monitoring of parabens and bisphenols in human saliva
    Naccarato, Attilio
    Elliani, Rosangela
    Tagarelli, Antonio
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1707
  • [9] Human Biomonitoring of Serum Polybrominated Diphenyl Ethers by Supported Liquid Extraction and Gas Chromatography Coupled With Tandem Mass Spectrometry
    Liu, Miao
    Jia, Xiangyu
    Peng, Rongfei
    Bai, Zhijun
    Yuan, Jun
    Tan, Lei
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (21)
  • [10] Simultaneous determination of parabens, bisphenols and alkylphenols in human placenta by ultra-high performance liquid chromatography-tandem mass spectrometry
    Van Overmeire, Ilse
    Vrijens, Karen
    Nawrot, Tim
    Van Nieuwenhuyse, An
    Van Loco, Joris
    Reyns, Tim
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1121 : 96 - 102