Monitoring Metformin in Cardiac Patients Exposed to Contrast Media Using Ultra-High-Performance Liquid Chromatography Tandem Mass-Spectrometry

被引:4
|
作者
Radwan, Mahasen A. [1 ]
Al Taweel, Esraa S. [1 ]
Al-Moghairi, Abdulrahman M. [2 ]
Aloudah, Nouf M. [1 ]
Al Babtain, Muneera A. [2 ]
Al-Amri, Hussein S. [2 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Clin Pharm, Riyadh, Saudi Arabia
[2] Riyadh Mil Hosp, Cardiac Catheterizat Lab, Adult Cardiol Dept, Prince Sultan Cardiac Ctr, Riyadh, Saudi Arabia
关键词
metformin; pharmacokinetics; UHPLC MS/MS; contrast media; therapeutic drug monitoring; lactic acidosis; DEPENDENT DIABETES-MELLITUS; HUMAN PLASMA; LACTIC-ACIDOSIS; INDUCED NEPHROPATHY; BIOLOGICAL-FLUIDS; HPLC; PHARMACOKINETICS; GUIDELINES; CONTRAINDICATIONS; LC/MS/MS;
D O I
10.1097/FTD.0b013e318237ab03
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: There is no evidence that the use of contrast media (CM) in diabetic patients with serum creatinine <130 mu mole/L leads to metformin accumulation and subsequent lactic acidosis. Therefore, the objective of this investigation was to monitor cardiac patients for the effects of CM on their metformin plasma concentration and serum creatinine clearance (ClCr). Methods: Metformin plasma concentrations were measured by a new, fully validated specific, precise, and accurate ultra-high-performance liquid chromatography tandem mass-spectrometric assay. The detection was performed using positive electrospray ionization in the multiple reaction monitoring mode. Fifty patients with serum creatinine levels <130 mu mole/L were monitored for the effect of CM exposure on metformin concentration and ClCr. Pharmacokinetic parameters were calculated in 8 of these patients, and metformin accumulation was monitored in 10 patients before and after their exposure to CM. Results: Linear response (r >= 0.998) was observed over the range of 5-2000 ng/mL of metformin, with the lower limit of quantification of 2.3 ng/mL. The intraday and interday precision (relative standard deviation) values were <13%, and the accuracy (relative error) was <- 10% for metformin concentrations. The assay was sensitive to follow the pharmacokinetics of metformin in humans during a dosing interval after an oral dose at steady state. Metformin pharmacokinetic parameters were estimated in 8 patients exposed to CM. The mean C-max of 1.9 +/- 0.6 mg/L was attained at 4.1 +/- 1.9 hours. There was no evidence of any drug accumulation or altered elimination due to the exposure to CM in the current population. ClCr showed no significant difference (P>0.05) before (92.8 +/- 11.3 mL/min) and after 48 hours (90.5 +/- 10.5 mL/min) of exposure to CM. Conclusions: Our data suggest that the recommendation to withhold metformin in diabetic patients during CM exposure could be revised to withholding the drug only in patients with moderate to severe renal dysfunction.
引用
收藏
页码:742 / 749
页数:8
相关论文
共 50 条
  • [11] Pharmacokinetic and metabolism studies of bavachinin through ultra-high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry
    Qian, Jun
    Xie, Fan
    Shi, Yanhong
    Li, Jinhang
    Zhang, Liuqiang
    Li, Yiming
    Guo, Fujiang
    Wang, Rui
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (10)
  • [12] Simultaneous determination of tiafenacil and its six metabolites in fruits using ultra-high-performance liquid chromatography/tandem mass spectrometry
    Hu, Mingfeng
    Tan, Huihua
    Li, Yihan
    Qiu, Jingsi
    Liu, Li
    Zeng, Dongqiang
    FOOD CHEMISTRY, 2020, 327 (327)
  • [13] Improvement and Validation of a High-Performance Liquid Chromatography in Tandem Mass Spectrometry Method for Monitoring of Omeprazole in Plasma
    Wojnicz, Aneta
    Gil Garcia, Ana Isabel
    Roman-Martinez, Manuel
    Ochoa-Mazarro, Dolores
    Abad-Santos, Francisco
    Ruiz-Nuno, Ana
    THERAPEUTIC DRUG MONITORING, 2015, 37 (03) : 381 - 388
  • [14] A Quantitative Analysis of Memantine in Human Plasma Using Ultra Performance Liquid Chromatography/Tandem Mass Spectrometry
    Dubey, Sunil K.
    Patni, Anil
    Khuroo, Arshad
    Thudi, Nageshwar R.
    Reyar, Simrit
    Kumar, Arun
    Tomar, Manoj S.
    Jain, Rakesh
    Kumar, Nand
    Monif, Tausif
    E-JOURNAL OF CHEMISTRY, 2009, 6 (04) : 1063 - 1070
  • [15] A rapid, sensitive method for clinical monitoring of ketamine and norketamine by ultra-high-performance reverse-phase liquid chromatography tandem mass spectrometry
    Armfield, Nicholas
    Frank, Bernhard
    Chadwick, Carrie
    ANNALS OF CLINICAL BIOCHEMISTRY, 2024, 61 (04) : 309 - 318
  • [16] Simultaneous determination of tilianin and its metabolites in mice using ultra-high-performance liquid chromatography with tandem mass spectrometry and its application to a pharmacokinetic study
    Wang, Liping
    Chen, Qingwei
    Zhu, Lijun
    Zeng, Xuejun
    Li, Qiang
    Hu, Ming
    Wang, Xinchun
    Liu, Zhongqiu
    BIOMEDICAL CHROMATOGRAPHY, 2018, 32 (04)
  • [17] A simple and rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine plasma biotin in hemodialysis patients
    Yagi, Shigeaki
    Nishizawa, Manabu
    Ando, Itiro
    Oguma, Shiro
    Sato, Emiko
    Imai, Yutaka
    Fujiwara, Masako
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (08) : 1285 - 1290
  • [18] Method Development for Aminopyralid Residues Determination by Ultra-High-Performance Liquid Chromatography Coupled to Tandem Mass Spectrometry in Straw
    Kurhan, Sebnem
    Hankova, Katerina
    Kloucek, Pavel
    Koudela, Martin
    SEPARATIONS, 2024, 11 (01)
  • [19] Analysis of multi-class pharmaceuticals in fish tissues by ultra-high-performance liquid chromatography tandem mass spectrometry
    Huerta, B.
    Jakimska, A.
    Gros, M.
    Rodriguez-Mozaz, S.
    Barcelo, D.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1288 : 63 - 72
  • [20] Determination of meloxicam in human plasma by ultra-high-performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Zhang, Siyao
    Chen, Shutong
    Song, Yujing
    Xin, Ying
    Cui, Ying
    Qin, Feng
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (08)