A mimotope peptide-based dual-signal readout competitive enzyme-linked immunoassay for non-toxic detection of zearalenone

被引:41
作者
Chen, Yanjie [1 ]
Zhang, Shupei [2 ]
Hong, Zhensheng [1 ]
Lin, Yanyu [3 ,4 ]
Dai, Hong [1 ,2 ]
机构
[1] Fujian Normal Univ, Coll Chem & Mat, Fuzhou 350108, Peoples R China
[2] Fujian Med Univ, Fujian Prov Matern & Childrens Hosp, Affiliated Hosp, Fuzhou 350108, Fujian, Peoples R China
[3] Fuzhou Univ, Minist Educ, Key Lab Anal & Detect Food Safety, Fuzhou 350002, Peoples R China
[4] Fuzhou Univ, Dept Chem, Fuzhou 350002, Peoples R China
基金
美国国家科学基金会;
关键词
RUTILE TIO2 MESOCRYSTALS; SCHOTTKY-BARRIER; SOLAR-CELLS; AMPLIFICATION; IMMUNOSENSOR; FLUORESCENCE; MYCOTOXINS; BIOSENSOR; ELECTRODE; PLATFORM;
D O I
10.1039/c9tb01167f
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this study, a mimotope peptide-based non-toxic photoelectrochemical (PEC) competitive enzyme-linked immunoassay (ELISA) was established for ultrasensitive detection of zearalenone (ZEN) with dual-signal readout. Using the phage display technique (PDT), a mimotope peptide of ZEN could be harvested by selecting a peptide from a phage-display peptide library, which avoided using mycotoxin itself and minimized potential damage to operators. The tyramine-modified rutile TiO2 mesocrystals (Tyr-RMC) with outstanding PEC properties were utilized as reporter units to label the mimotope peptide. The fabricated peptide@Tyr-RMC probe could anchor on the antibody-modified electrode via competitive immune recognition of free target ZEN. When subjected to catalysis of HRP-H2O2, the Tyr-RMC composite was deposited at the enzyme reaction site, causing rolling circle extension of the reporter unit chains. By merit of the brilliant signal amplification effect of tyramine signal amplification (TSA), dramatically enhanced photocurrent response and enormously increased electrochemical impedance could be determined. Combining all of these advantages, the developed dual-signal readout non-toxicity immunoassay could effectively decrease environmental interference. Also, the designed dual-signal readout biosensor demonstrated a wide linear range between 10(-6) and 1 ng mL(-1) with a low detection limit of 1 x 10(-6) ng mL(-1), which provides a valuable reference for developing highly efficient, secure and sensitive detection methods and indicates promising applicability in food testing.
引用
收藏
页码:6972 / 6980
页数:9
相关论文
共 41 条
  • [1] Calibration Curves in Quantitative Ligand Binding Assays: Recommendations and Best Practices for Preparation, Design, and Editing of Calibration Curves
    Azadeh, Mitra
    Gorovits, Boris
    Kamerud, John
    MacMannis, Stephen
    Safavi, Afshin
    Sailstad, Jeffrey
    Sondag, Perceval
    [J]. AAPS JOURNAL, 2018, 20 (01):
  • [2] An injectable enzymatically crosslinked tyramine-modified carboxymethyl chitin hydrogel for biomedical applications
    Bi, Bo
    Liu, Hui
    Kang, Wenting
    Zhuo, Renxi
    Jiang, Xulin
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 175 : 614 - 624
  • [3] Determination of rate constants for charge transfer and the distribution of semiconductor and electrolyte electronic energy levels in dye-sensitized solar cells by open-circuit photovoltage decay method
    Bisquert, J
    Zaban, A
    Greenshtein, M
    Mora-Seró, I
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (41) : 13550 - 13559
  • [4] Excellent graphitic carbon nitride nanosheets-based photoelectrochemical platform motivated by Schottky barrier and LSPR effect and its sensing application
    Dai, Hong
    Zhang, Shupei
    Li, Yilin
    Lin, Yanyu
    [J]. ANALYST, 2015, 140 (10) : 3514 - 3520
  • [5] A novel and simple cell-based electrochemical impedance biosensor for evaluating the combined toxicity of DON and ZEN
    Gu, Wenshu
    Zhu, Pei
    Jiang, Donglei
    He, Xingxing
    Li, Yun
    Ji, Jian
    Zhang, Lijuan
    Sun, Yange
    Sun, Xiulan
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 70 : 447 - 454
  • [6] Poly (glycine) modified carbon paste electrode for simultaneous determination of catechol and hydroquinone: A voltammetric study
    Harisha, K. V.
    Swamy, B. E. Kumara
    Ebenso, Eno E.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 823 : 730 - 736
  • [7] Phage-displayed peptides that mimic zearalenone and its application in immunoassay
    He, Qing-Hua
    Xu, Yang
    Huang, Yun-Hong
    Liu, Ren-Rong
    Huang, Zhi-Bing
    Li, Yan-Ping
    [J]. FOOD CHEMISTRY, 2011, 126 (03) : 1312 - 1315
  • [8] Simplified calibration and analysis on screen-printed disposable platforms for electrochemical magnetic bead-based inmunosensing of zearalenone in baby food samples
    Hervas, Mirian
    Angel Lopez, Miguel
    Escarpa, Alberto
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 25 (07) : 1755 - 1760
  • [9] Facile synthesis of rutile TiO2 mesocrystals with enhanced sodium storage properties
    Hong, Zhensheng
    Zhou, Kaidiang
    Zhang, Junwen
    Huang, Zhigao
    Wei, Mingdeng
    [J]. JOURNAL OF MATERIALS CHEMISTRY A, 2015, 3 (33) : 17412 - 17416
  • [10] Tyramine-Based Enzymatic Conjugate Repeats for Ultrasensitive Immunoassay Accompanying Tyramine Signal Amplification with Enzymatic Biocatalytic Precipitation
    Hou, Li
    Tang, Yun
    Xu, Mingdi
    Gao, Zhuangqiang
    Tang, Dianping
    [J]. ANALYTICAL CHEMISTRY, 2014, 86 (16) : 8352 - 8358