Accuracy of endoscopic ultrasound elastography used for differential diagnosis of focal pancreatic masses: a multicenter study

被引:123
作者
Saftoiu, A. [1 ]
Vilmann, P. [2 ]
Gorunescu, F.
Janssen, J. [3 ]
Hocke, M. [4 ]
Larsen, M. [5 ]
Iglesias-Garcia, J. [6 ]
Arcidiacono, P. [7 ]
Will, U. [8 ]
Giovannini, M. [9 ]
Dietrich, C. [10 ]
Havre, R. [11 ,12 ]
Gheorghe, C. [13 ]
McKay, C. [14 ]
Gheonea, D. I. [1 ]
Ciurea, T. [1 ]
机构
[1] Univ Med & Pharm, Dept Gastroenterol, Craiova, Romania
[2] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Surg Gastroenterol, DK-1168 Copenhagen, Denmark
[3] Univ Witten Herdecke, Helios Klinikum, Wuppertal, Germany
[4] Hosp Meiningen, Dept Internal Med 2, Meiningen, Germany
[5] Odense Univ Hosp, Ctr Surg Ultrasound, Dept Surg, DK-5000 Odense, Denmark
[6] Univ Hosp, Santiago De Compostela, Spain
[7] Univ Vita Salute San Raffaele, Gastroenterol & Gastrointestinal Endoscopy Unit, Milan, Italy
[8] SRH Wald Klinikum, Gera, Germany
[9] Paoli Calmettes Inst, Endoscop Unit, Marseilles, France
[10] Caritas Krankenhaus, Med Klin 2, Bad Mergentheim, Germany
[11] Haukeland Hosp, Natl Ctr Ultrasound Gastroenterol, N-5021 Bergen, Norway
[12] Univ Bergen, Inst Med, Bergen, Norway
[13] Fundeni Clin Inst, Ctr Gastroenterol & Hepatol, Bucharest, Romania
[14] Glasgow Royal Infirm, Glasgow G4 0SF, Lanark, Scotland
关键词
FINE-NEEDLE-ASPIRATION; EUS-GUIDED FNA; INTEROBSERVER AGREEMENT; LYMPH-NODES; CANCER; LESIONS; BIOPSY; YIELD; PATTERN; SYSTEM;
D O I
10.1055/s-0030-1256314
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: Endoscopic ultrasound (EUS) elastography represents a new imaging procedure that might characterize the differences of hardness and strain between diseased tissue and normal tissue. The aim of this study was to assess the efficiency of EUS elastography for the differentiation of focal masses in chronic pancreatitis and pancreatic cancer. Patients and methods: The study group comprised 258 patients with focal pancreatic masses included prospectively at 13 participating centers. Qualitative analysis of the diagnoses made by two expert doctors using all recorded video clips was performed in order to test the interobserver variability. A post-processing software analysis was used to examine the EUS elastography videos by calculating average-hue histograms of individual elastography images. The quantitative information was used to calculate intra-observer variability and the accuracy of the method. Results: Qualitative analysis of the recorded videos revealed a kappa value of 0.72. Intra-observer variability analysis revealed that the single measure intraclass correlation ranged between 0.86 and 0.94. The average-hue histogram analysis of the data indicated a sensitivity of 93.4 %, a specificity of 66.0 %, a positive predictive value of 92.5 %, a negative predictive value of 68.9 %, and an overall accuracy of 85.4 %, based on a cut-off value of 175. Area under the receiver operating characteristic curve (AUROC) was 0.854 (P < 0.0001) with a confidence interval of 0.804-0.894. Conclusion: The value of quantitative analysis of EUS elastography recordings was proven by good reproducibility of the videos, as well as good parameters of the AUROC analysis. (Clinical Trials.gov identifier: CT00909103).
引用
收藏
页码:596 / 603
页数:8
相关论文
共 50 条
  • [21] Endoscopic ultrasound in the diagnosis and staging of pancreatic cancer
    Iglesias Garcia, J.
    Larino Noia, J.
    Dominguez Munoz, J. E.
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2009, 101 (09) : 631 - 638
  • [22] Endoscopic Ultrasound-Guided Fine Needle Aspiration versus Percutaneous Ultrasound-Guided Fine Needle Aspiration in Diagnosis of Focal Pancreatic Masses
    Okasha, Hussein Hassan
    Naga, Mazen Ibrahim
    Esmat, Serag
    Naguib, Mohamed
    Hassanein, Mohamed
    Hassani, Mohamed
    El-Kassas, Mohamed
    Mahdy, Reem Ezzat
    El-Gemeie, Emad
    Farag, Ali Hassan
    Foda, Ayman Mohamed
    ENDOSCOPIC ULTRASOUND, 2013, 2 (04) : 190 - 193
  • [23] Clinical Study of Ultrasound Elastography in Qualitative Diagnosis of Breast Masses
    Duan, Qing
    Zhuo, Na
    Sun, Tong
    Zhang, Xuening
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2021, 11 (03) : 1020 - 1027
  • [24] Impact of endoscopic ultrasound-guided fine needle biopsy for diagnosis of pancreatic masses
    Julio Iglesias-Garcia
    Enrique Dominguez-Munoz
    Antonio Lozano-Leon
    Ihab Abdulkader
    Jose Larino-Noia
    Jose Antunez
    Jeronimo Forteza
    World Journal of Gastroenterology, 2007, (02) : 289 - 293
  • [25] Impact of endoscopic ultrasound-guided fine needle biopsy for diagnosis of pancreatic masses
    Iglesias-Garcia, Julio
    Dominguez-Munoz, Enrique
    Lozano-Leon, Antonio
    Abdulkader, Ihab
    Larino-Noia, Jose
    Antunez, Jose
    Forteza, Jeronimo
    WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (02) : 289 - 293
  • [26] Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles
    Antonini, Filippo
    Fuccio, Lorenzo
    Giorgini, Sara
    Fabbri, Carlo
    Frazzoni, Leonardo
    Scarpelli, Marina
    Macarri, Giampiero
    DIGESTIVE AND LIVER DISEASE, 2017, 49 (08) : 898 - 902
  • [27] Histologic diagnosis of pancreatic masses using 25-gauge endoscopic ultrasound needles with and without a core trap: a multicenter randomized trial
    Kamata, Ken
    Kitano, Masayuki
    Yasukawa, Satoru
    Kudo, Masatoshi
    Chiba, Yasutaka
    Ogura, Takeshi
    Higuchi, Kazuhide
    Fukutake, Nobuyasu
    Ashida, Reiko
    Yamasaki, Tomoaki
    Nebiki, Hiroko
    Hirose, Satoru
    Hoki, Noriyuki
    Asada, Masanori
    Yazumi, Shujiro
    Takaoka, Makoto
    Okazaki, Kazuichi
    Matsuda, Fumihiro
    Okabe, Yoshihiro
    Yanagisawa, Akio
    ENDOSCOPY, 2016, 48 (07) : 632 - 638
  • [28] Combined contrast-enhanced power Doppler and real-time sonoelastography performed during EUS, used in the differential diagnosis of focal pancreatic masses (with videos)
    Saftoiu, Adrian
    Iordache, Sevastita
    Gheonea, Dan Ionu
    Popescu, Carmen
    Malos, Anca
    Gorunescu, Florin
    Ciurea, Tudorel
    Iordache, Alexandru
    Popescu, Gabriel Lucian
    Manea, Catalin
    GASTROINTESTINAL ENDOSCOPY, 2010, 72 (04) : 739 - 747
  • [29] Differentiation of Pancreatic Masses via Endoscopic Ultrasound Strain Ratio Elastography Using Adjacent Pancreatic Tissue as the Reference
    Rustemovic, Nadan
    Kalauz, Mirjana
    Ravic, Katja Grubelic
    Ivekovic, Hrvoje
    Bilic, Branko
    Ostojic, Zvonimir
    Opacic, Dalibor
    Ledinsky, Iva
    Majerovic, Matea
    Visnjic, Ana
    PANCREAS, 2017, 46 (03) : 347 - 351
  • [30] Diagnosis of vascular invasion in pancreatic ductal adenocarcinoma using endoscopic ultrasound elastography
    Yamada, Kenta
    Kawashima, Hiroki
    Ohno, Eizaburo
    Ishikawa, Takuya
    Tanaka, Hiroyuki
    Nakamura, Masanao
    Miyahara, Ryoji
    Ishigami, Masatoshi
    Hirooka, Yoshiki
    Fujishiro, Mitsuhiro
    BMC GASTROENTEROLOGY, 2020, 20 (01)