共 50 条
Accuracy of endoscopic ultrasound elastography used for differential diagnosis of focal pancreatic masses: a multicenter study
被引:120
|作者:
Saftoiu, A.
[1
]
Vilmann, P.
[2
]
Gorunescu, F.
Janssen, J.
[3
]
Hocke, M.
[4
]
Larsen, M.
[5
]
Iglesias-Garcia, J.
[6
]
Arcidiacono, P.
[7
]
Will, U.
[8
]
Giovannini, M.
[9
]
Dietrich, C.
[10
]
Havre, R.
[11
,12
]
Gheorghe, C.
[13
]
McKay, C.
[14
]
Gheonea, D. I.
[1
]
Ciurea, T.
[1
]
机构:
[1] Univ Med & Pharm, Dept Gastroenterol, Craiova, Romania
[2] Univ Copenhagen, Gentofte & Herlev Hosp, Dept Surg Gastroenterol, DK-1168 Copenhagen, Denmark
[3] Univ Witten Herdecke, Helios Klinikum, Wuppertal, Germany
[4] Hosp Meiningen, Dept Internal Med 2, Meiningen, Germany
[5] Odense Univ Hosp, Ctr Surg Ultrasound, Dept Surg, DK-5000 Odense, Denmark
[6] Univ Hosp, Santiago De Compostela, Spain
[7] Univ Vita Salute San Raffaele, Gastroenterol & Gastrointestinal Endoscopy Unit, Milan, Italy
[8] SRH Wald Klinikum, Gera, Germany
[9] Paoli Calmettes Inst, Endoscop Unit, Marseilles, France
[10] Caritas Krankenhaus, Med Klin 2, Bad Mergentheim, Germany
[11] Haukeland Hosp, Natl Ctr Ultrasound Gastroenterol, N-5021 Bergen, Norway
[12] Univ Bergen, Inst Med, Bergen, Norway
[13] Fundeni Clin Inst, Ctr Gastroenterol & Hepatol, Bucharest, Romania
[14] Glasgow Royal Infirm, Glasgow G4 0SF, Lanark, Scotland
来源:
关键词:
FINE-NEEDLE-ASPIRATION;
EUS-GUIDED FNA;
INTEROBSERVER AGREEMENT;
LYMPH-NODES;
CANCER;
LESIONS;
BIOPSY;
YIELD;
PATTERN;
SYSTEM;
D O I:
10.1055/s-0030-1256314
中图分类号:
R57 [消化系及腹部疾病];
学科分类号:
摘要:
Background and study aims: Endoscopic ultrasound (EUS) elastography represents a new imaging procedure that might characterize the differences of hardness and strain between diseased tissue and normal tissue. The aim of this study was to assess the efficiency of EUS elastography for the differentiation of focal masses in chronic pancreatitis and pancreatic cancer. Patients and methods: The study group comprised 258 patients with focal pancreatic masses included prospectively at 13 participating centers. Qualitative analysis of the diagnoses made by two expert doctors using all recorded video clips was performed in order to test the interobserver variability. A post-processing software analysis was used to examine the EUS elastography videos by calculating average-hue histograms of individual elastography images. The quantitative information was used to calculate intra-observer variability and the accuracy of the method. Results: Qualitative analysis of the recorded videos revealed a kappa value of 0.72. Intra-observer variability analysis revealed that the single measure intraclass correlation ranged between 0.86 and 0.94. The average-hue histogram analysis of the data indicated a sensitivity of 93.4 %, a specificity of 66.0 %, a positive predictive value of 92.5 %, a negative predictive value of 68.9 %, and an overall accuracy of 85.4 %, based on a cut-off value of 175. Area under the receiver operating characteristic curve (AUROC) was 0.854 (P < 0.0001) with a confidence interval of 0.804-0.894. Conclusion: The value of quantitative analysis of EUS elastography recordings was proven by good reproducibility of the videos, as well as good parameters of the AUROC analysis. (Clinical Trials.gov identifier: CT00909103).
引用
收藏
页码:596 / 603
页数:8
相关论文