Multiple-image radiography

被引:230
作者
Wernick, MN
Wirjadi, O
Chapman, D
Zhong, Z
Galatsanos, NP
Yang, YY
Brankov, JG
Oltulu, O
Anastasio, MA
Muehleman, C
机构
[1] IIT, Dept Elect & Comp Engn, Chicago, IL 60616 USA
[2] IIT, Dept Phys, Chicago, IL 60616 USA
[3] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
[4] IIT, Dept Biomed Engn, Chicago, IL 60616 USA
[5] Rush Med Coll, Dept Anat & Cell Biol, Chicago, IL 60612 USA
关键词
PHASE-CONTRAST; DIFFRACTION; REFRACTION;
D O I
10.1088/0031-9155/48/23/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional radiography produces a single image of an object by measuring the attenuation of an x-ray beam passing through it. When imaging weakly absorbing tissues, x-ray attenuation may be a suboptimal signature of disease-related information. In this paper we describe a new phase-sensitive imaging method, called multiple-image radiography (MIR), which is an improvement on a prior technique called diffraction-enhanced imaging (DEI). This paper elaborates on our initial presentation of the idea in Wernick et al (2002 Proc. Int. Symp. Biomed. Imaging pp 129-32). MIR simultaneously produces several images from a set of measurements made with a single x-ray beam. Specifically, MIR yields three images depicting separately the effects of refraction, ultrasmall-angle scatter and attenuation by the object. All three images have good contrast, in part because they are virtually immune from degradation due to scatter at higher angles. MIR also yields a very comprehensive object description, consisting of the angular intensity spectrum of a transmitted x-ray beam at every image pixel, within a narrow angular range. Our experiments are based on data acquired using a synchrotron light source; however, in preparation for more practical implementations using conventional x-ray sources, we develop and evaluate algorithms designed for Poisson noise, which is characteristic of photon-limited imaging. The results suggest that MIR is capable of operating at low photon count levels, therefore the method shows promise for use with conventional x-ray sources. The results also show that, in addition to producing new types of object descriptions, MIR produces substantially more accurate images than its predecessor, DEL MIR results are shown in the form of planar images of a phantom and a biological specimen. A preliminary demonstration of the use of MIR for computed tomography is also presented.
引用
收藏
页码:3875 / 3895
页数:21
相关论文
共 20 条
  • [1] Als-Nielsen J., 2001, ELEMENTS MODERN XRAY
  • [2] Diffraction enhanced x-ray imaging
    Chapman, D
    Thomlinson, W
    Johnston, RE
    Washburn, D
    Pisano, E
    Gmur, N
    Zhong, Z
    Menk, R
    Arfelli, F
    Sayers, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) : 2015 - 2025
  • [3] Chapman D., 1998, Synchrotron. Radiat. News, V11, P4, DOI [10.1080/08940889808260849, DOI 10.1080/08940889808260849]
  • [4] MAXIMUM LIKELIHOOD FROM INCOMPLETE DATA VIA EM ALGORITHM
    DEMPSTER, AP
    LAIRD, NM
    RUBIN, DB
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-METHODOLOGICAL, 1977, 39 (01): : 1 - 38
  • [5] Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method
    Dilmanian, FA
    Zhong, Z
    Ren, B
    Wu, XY
    Chapman, LD
    Orion, I
    Thomlinson, WC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (04) : 933 - 946
  • [6] Phase-sensitive x-ray imaging
    Fitzgerald, R
    [J]. PHYSICS TODAY, 2000, 53 (07) : 23 - 26
  • [7] GALATSANOS NP, 2000, HDB IMAGE VIDEO PROC, P155
  • [8] STOCHASTIC RELAXATION, GIBBS DISTRIBUTIONS, AND THE BAYESIAN RESTORATION OF IMAGES
    GEMAN, S
    GEMAN, D
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1984, 6 (06) : 721 - 741
  • [9] BAYESIAN RECONSTRUCTIONS FROM EMISSION TOMOGRAPHY DATA USING A MODIFIED EM ALGORITHM
    GREEN, PJ
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (01) : 84 - 93
  • [10] Regimes of X-ray phase-contrast imaging with perfect crystals
    Gureyev, TE
    Wilkins, SW
    [J]. NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA D-CONDENSED MATTER ATOMIC MOLECULAR AND CHEMICAL PHYSICS FLUIDS PLASMAS BIOPHYSICS, 1997, 19 (2-4): : 545 - 552