Validation and test-retest repeatability performance of parametric methods for [11C]UCB-J PET

被引:5
作者
Tuncel, Hayel [1 ]
Boellaard, Ronald [1 ]
Coomans, Emma M. [1 ]
den Hollander-Meeuwsen, Marijke [1 ]
de Vries, Erik F. J. [2 ]
Glaudemans, Andor W. J. M. [2 ]
Feltes, Paula Kopschina [2 ]
Garcia, David Vallez [2 ]
Verfaillie, Sander C. J. [1 ]
Wolters, Emma E. [1 ,3 ]
Sweeney, Steven P. [4 ]
Ryan, J. Michael [4 ]
Ivarsson, Magnus [4 ]
Lynch, Berkley A. [4 ]
Schober, Patrick [5 ]
Scheltens, Philip [3 ]
Schuit, Robert C. [1 ]
Windhorst, Albert D. [1 ]
De Deyn, Peter P. [6 ,7 ]
van Berckel, Bart N. M. [1 ]
Golla, Sandeep S., V [1 ]
机构
[1] Amsterdam UMC, Dept Radiol & Nucl Med, Amsterdam Neurosci, De Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
[2] Univ Groningen, Univ Med Ctr, Dept Nucl Med & Mol Imaging, Groningen, Netherlands
[3] Amsterdam UMC, Dept Neurol, Alzheimer Ctr Amsterdam, Amsterdam Neurosci, Amsterdam, Netherlands
[4] Rodin Therapeut Inc, Cambridge, MA USA
[5] Amsterdam UMC, Dept Anaesthesiol, Amsterdam, Netherlands
[6] Univ Groningen, Univ Med Ctr Groningen, Dept Neurol, Groningen, Netherlands
[7] Univ Groningen, Univ Med Ctr Groningen, Alzheimer Res Ctr, Groningen, Netherlands
关键词
Alzheimer's disease; C-11]UCB-J; Parametric methods; PET; SV2A; ALZHEIMERS-DISEASE; GRAPHICAL ANALYSIS; HUMAN BRAIN; NATIONAL INSTITUTE; TRANSPORTER; GUIDELINES; BINDING; NOISE;
D O I
10.1186/s13550-021-00874-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
[C-11]UCB-J is a PET radioligand that binds to the presynaptic vesicle glycoprotein 2A. Therefore, [C-11]UCB-J PET may serve as an in vivo marker of synaptic integrity. The main objective of this study was to evaluate the quantitative accuracy and the 28-day test-retest repeatability (TRT) of various parametric quantitative methods for dynamic [C-11]UCB-J studies in Alzheimer's disease (AD) patients and healthy controls (HC). Eight HCs and seven AD patients underwent two 60-min dynamic [C-11]UCB-J PET scans with arterial sampling over a 28-day interval. Several plasma-input based and reference-region based parametric methods were used to generate parametric images using metabolite corrected plasma activity as input function or white matter semi-ovale as reference region. Different parametric outcomes were compared regionally with corresponding non-linear regression (NLR) estimates. Furthermore, the 28-day TRT was assessed for all parametric methods. Spectral analysis (SA) and Logan graphical analysis showed high correlations with NLR estimates. Receptor parametric mapping (RPM) and simplified reference tissue model 2 (SRTM2) BPND, and reference Logan (RLogan) distribution volume ratio (DVR) regional estimates correlated well with plasma-input derived DVR and SRTM BPND. Among the multilinear reference tissue model (MRTM) methods, MRTM1 had the best correspondence with DVR and SRTM BPND. Among the parametric methods evaluated, spectral analysis (SA) and SRTM2 were the best plasma-input and reference tissue methods, respectively, to obtain quantitatively accurate and repeatable parametric images for dynamic [C-11]UCB-J PET.
引用
收藏
页数:12
相关论文
共 35 条
[1]  
Alkermes I, 2019, VIVITROL
[2]   DIFFERENTIAL EXPRESSION OF SYNAPTIC VESICLE PROTEIN-2 (SV2) ISOFORMS [J].
BAJJALIEH, SM ;
FRANTZ, GD ;
WEIMANN, JM ;
MCCONNELL, SK ;
SCHELLER, RH .
JOURNAL OF NEUROSCIENCE, 1994, 14 (09) :5223-5235
[3]   Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET [J].
Boellaard, R ;
van Lingen, A ;
van Balen, SCM ;
Hoving, BG ;
Lammertsma, AA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (01) :81-89
[4]   PPET: A software tool for kinetic and parametric analyses of dynamic PET studies [J].
Boellaard, Ronald ;
Yaqub, M. ;
Lubberink, M. ;
Lammertsma, A. .
NEUROIMAGE, 2006, 31 :T62-T62
[5]   A Variational Bayesian inference method for parametric imaging of PET data [J].
Castellaro, M. ;
Rizzo, G. ;
Tonietto, M. ;
Veronese, M. ;
Turkheimer, F. E. ;
Chappell, M. A. ;
Bertoldo, A. .
NEUROIMAGE, 2017, 150 :136-149
[6]   SPECTRAL-ANALYSIS OF DYNAMIC PET STUDIES [J].
CUNNINGHAM, VJ ;
JONES, T .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1993, 13 (01) :15-23
[7]   SYNAPSE LOSS IN FRONTAL-CORTEX BIOPSIES IN ALZHEIMERS-DISEASE - CORRELATION WITH COGNITIVE SEVERITY [J].
DEKOSKY, ST ;
SCHEFF, SW .
ANNALS OF NEUROLOGY, 1990, 27 (05) :457-464
[8]   Imaging synaptic density in the living human brain [J].
Finnema, Sjoerd J. ;
Nabulsi, Nabeel B. ;
Eid, Tore ;
Detyniecki, Kamil ;
Lin, Shu-fei ;
Chen, Ming-Kai ;
Dhaher, Roni ;
Matuskey, David ;
Baum, Evan ;
Holden, Daniel ;
Spencer, Dennis D. ;
Mercier, Joel ;
Hannestad, Jonas ;
Huang, Yiyun ;
Carson, Richard E. .
SCIENCE TRANSLATIONAL MEDICINE, 2016, 8 (348)
[9]   Parametric imaging of ligand-receptor binding in PET using a simplified reference region model [J].
Gunn, RN ;
Lammertsma, AA ;
Hume, SP ;
Cunningham, VJ .
NEUROIMAGE, 1997, 6 (04) :279-287
[10]   Three-dimensional maximum probability atlas of the human brain, with particular reference to the temporal lobe [J].
Hammers, A ;
Allom, R ;
Koepp, MJ ;
Free, SL ;
Myers, R ;
Lemieux, L ;
Mitchell, TN ;
Brooks, DJ ;
Duncan, JS .
HUMAN BRAIN MAPPING, 2003, 19 (04) :224-247