Determination of Salicylic Acid by Differential Pulse Voltammetry Using ZnO/Al2O3 Nanocomposite Modified Graphite Screen Printed Electrode

被引:31
作者
Ganjali, Mohammad Reza [1 ,2 ]
Nejad, Fariba Garkani [3 ]
Tajik, Somayeh [4 ]
Beitollahi, Hadi [4 ]
Pourbasheer, Eslam [5 ]
Larijanii, Bagher [6 ]
机构
[1] Univ Tehran, Ctr Excellence Electrochem, Sch Chem, Coll Sci, Tehran, Iran
[2] Univ Tehran Med Sci, Biosensor Res Ctr, Endocrinol & Metab Mol Cellular Sci Inst, Tehran, Iran
[3] Grad Univ Adv Technol, Dept Chem, Kerman, Iran
[4] Grad Univ Adv Technol, Environm Dept, Inst Sci & High Technol & Environm Sci, Kerman, Iran
[5] Payame Noor Univ, Dept Chem, POB 19395-3697, Tehran, Iran
[6] Univ Tehran Med Sci, Endocrinol & Metab Res Ctr, Endocrinol & Metab Mol Cellular Sci Inst, Tehran, Iran
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2017年 / 12卷 / 11期
关键词
Salicylic acid; ZnO/Al2O3; nanocomposite; Graphite screen printed electrode; Voltammetry; Real sample analysis; CARBON-PASTE ELECTRODE; CONTINUOUS CYCLIC VOLTAMMETRY; SUPERPARAMAGNETIC FE3O4 NANOPARTICLES; ELECTROCHEMICAL-BEHAVIOR; URIC-ACID; PHARMACEUTICAL FORMULATIONS; IMPRINTED POLYMER; AU MICROELECTRODE; SENSING PLATFORM; ASCORBIC-ACID;
D O I
10.20964/2017.11.49
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple strategy for determination of salicylic acid (SA) based on ZnO/Al2O3 nanocomposite modified graphite screen printed electrode (ZnO/Al2O3/SPE) is reported. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were employed to evaluate the performance of the sensor. The ZnO/Al2O3/SPE demonstrated noticeable electrochemical catalytic activity. The oxidation of salicylic acid at ZnO/Al2O3/SPE was accompanied by the considerable decrease in overpotential and dramatic increase in peak current. The response of salicylic acid under the optimized conditions is linear within the ranges of 0.5-80.0 mu M. A low detection limit of 0.25 mu M was found for salicylic acid target. The function of this modified electrode in the concentration measurement of the real samples such as urine and pharmaceuticals was acceptable and approved its practical application.
引用
收藏
页码:9972 / 9982
页数:11
相关论文
共 50 条
  • [31] DETERMINATION OF NAPROXEN BY USING DIFFERENTIAL PULSE VOLTAMMETRY WITH POLY(ANILINE-2-SULFONIC ACID) MODIFIED BORON DOPED DIAMOND ELECTRODE
    Gungor, Oznur
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2022, 41 (01) : 11 - 20
  • [32] Simultaneous determination of acetaminophen and dopamine using SWCNT modified carbon-ceramic electrode by differential pulse voltammetry
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    Pournaghi-Azar, Mohammad Hossein
    ELECTROCHIMICA ACTA, 2011, 56 (07) : 2888 - 2894
  • [33] Determination of U(VI) by differential pulse stripping voltammetry using a polydopamine/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Guo, Weihua
    Xu, Huiling
    Chen, Cheng
    Cao, Xiaohong
    Ma, Jianguo
    Liu, Yunhai
    MICROCHEMICAL JOURNAL, 2022, 175
  • [34] Sensitive and Rapid Detection of Aspartic Acid with Co3O4-ZnO Nanorods Using Differential Pulse Voltammetry
    Alfaifi, Sulaiman Y.
    Adeosun, Waheed Abiodun
    Asiri, Abdullah M.
    Rahman, Mohammed M.
    BIOSENSORS-BASEL, 2023, 13 (01):
  • [35] Pulse Vacuum Flashover of Al2O3/Epoxy Nanocomposite
    Cheng Yonghong
    Chen Yu
    Wang Zengbin
    Wu Kai
    ISEIM 2008: PROCEEDINGS OF 2008 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING, 2008, : 23 - 23
  • [36] Simultaneous determination of ascorbic acid, dopamine and uric acid by use of a MWCNT modified carbon-ceramic electrode and differential pulse voltammetry
    Habibi, Biuck
    Pournaghi-Azar, Mohammad Hossien
    ELECTROCHIMICA ACTA, 2010, 55 (19) : 5492 - 5498
  • [37] Voltammetric determination of ascorbic acid by using a disposable screen printed electrode modified with Cu(OH)2 nanorods
    Raveendran, Jeethu
    Krishnan, Rajasree G.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    MICROCHIMICA ACTA, 2017, 184 (09) : 3573 - 3579
  • [38] Graphene Oxide/ZnO Nano Composite for Sensitive and Selective Electrochemical Sensing of Levodopa and Tyrosine Using Modified Graphite Screen Printed Electrode
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    ELECTROANALYSIS, 2016, 28 (09) : 2237 - 2244
  • [39] Highly selective determination of ascorbic acid, epinephrine, and uric acid by differential pulse voltammetry using poly(Adizol Black B)-modified glassy carbon electrode
    M. Taei
    M. Jamshidi
    Journal of Solid State Electrochemistry, 2014, 18 : 673 - 683
  • [40] One pot green synthesis of novel rGO@ZnO nanocomposite and fabrication of electrochemical sensor for ascorbic acid using screen-printed electrode
    Manjunatha, Channegowda
    Chirag, Venkateshaiah
    Shivaraj, Basavaraj Wali
    Srinivasa, Narasimha
    Ashoka, Siddaramanna
    JOURNAL OF NANOSTRUCTURES, 2020, 10 (03) : 531 - 539