Unidirectional, electrotactic-response valve for Caenorhabditis elegans in microfluidic devices

被引:11
作者
Carr, John A. [1 ]
Lycke, Roy [1 ]
Parashar, Archana [1 ]
Pandey, Santosh [1 ]
机构
[1] Iowa State Univ, Dept Elect & Comp Engn, Ames, IA 50011 USA
关键词
ON-CHIP; C; ELEGANS; BEHAVIOR; SYSTEM; NEUROBIOLOGY; INTEGRATION; BACTERIA; CIRCUIT; PUMPS;
D O I
10.1063/1.3570629
中图分类号
O59 [应用物理学];
学科分类号
摘要
We report a nematode electrotactic-response valve (NERV) to control the locomotion of Caenorhabditis elegans (C. elegans) in microfluidic devices. This nonmechanical, unidirectional valve is based on creating a confined region of lateral electric field that is switchable and reversible. We observed that C. elegans do not prefer to pass through this region if the field lines are incident to its forward movement. Upon reaching the boundary of the NERV, the incident worms partially penetrate the field region, pull back, and turn around. The NERV is tested on three C. elegans mutants: wild-type (N2), lev-8, and acr-16. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3570629]
引用
收藏
页数:3
相关论文
共 28 条
[1]   Long-term monitoring of bacteria undergoing programmed population control in a microchemostat [J].
Balagaddé, FK ;
You, LC ;
Hansen, CL ;
Arnold, FH ;
Quake, SR .
SCIENCE, 2005, 309 (5731) :137-140
[2]   A PDMS pinch-valve module embedded in rigid polymer lab chips for on-chip flow regulation [J].
Browne, Andrew W. ;
Hitchcock, Kathryn E. ;
Ahn, Chong H. .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2009, 19 (11)
[3]  
CARR J, 2010, COMMUNICATION 1111
[4]   Dissecting a circuit for olfactory behaviour in Caenorhabditis elegans [J].
Chalasani, Sreekanth H. ;
Chronis, Nikos ;
Tsunozaki, Makoto ;
Gray, Jesse M. ;
Ramot, Daniel ;
Goodman, Miriam B. ;
Bargmann, Cornelia I. .
NATURE, 2007, 450 (7166) :63-+
[5]   Microfluidic bioassay to characterize parasitic nematode phenotype and anthelmintic resistance [J].
Chen, Baozhen ;
Deutmeyer, Alex ;
Carr, John ;
Robertson, Alan P. ;
Martin, Richard J. ;
Pandey, Santosh .
PARASITOLOGY, 2011, 138 (01) :80-88
[6]   CO2 and compressive immobilization of C. elegans on-chip [J].
Chokshi, Trushal Vijaykumar ;
Ben-Yakar, Adela ;
Chronis, Nikos .
LAB ON A CHIP, 2009, 9 (01) :151-157
[7]   Microfluidics for in vivo imaging of neuronal and behavioral activity in Caenorhabditis elegans [J].
Chronis, Nikos ;
Zimmer, Manuel ;
Bargmann, Cornelia I. .
NATURE METHODS, 2007, 4 (09) :727-731
[8]   Worm chips: Microtools for C. elegans biology [J].
Chronis, Nikos .
LAB ON A CHIP, 2010, 10 (04) :432-437
[9]   Automated on-chip rapid microscopy, phenotyping and sorting of C. elegans [J].
Chung, Kwanghun ;
Crane, Matthew M. ;
Lu, Hang .
NATURE METHODS, 2008, 5 (07) :637-643
[10]   Neural circuits mediate electrosensory behavior in Caenorhabditis elegans [J].
Gabel, Christopher V. ;
Gabel, Harrison ;
Pavlichin, Dmitri ;
Kao, Albert ;
Clark, Damon A. ;
Samuel, Aravinthan D. T. .
JOURNAL OF NEUROSCIENCE, 2007, 27 (28) :7586-7596