EVALUATION OF EFFECTS OF JPEG2000 COMPRESSION ON A COMPUTER-AIDED DETECTION SYSTEM FOR PROSTATE CANCER ON DIGITIZED HISTOPATHOLOGY

被引:11
|
作者
Doyle, Scott [1 ]
Monaco, James [1 ]
Madabhushi, Anant [1 ]
Lindholm, Stefan [2 ]
Ljung, Patric [2 ]
Ladic, Lance [2 ]
Tomaszewski, John [3 ]
Feldman, Michael [3 ]
机构
[1] Rutgers State Univ, Dept Biomed Engn, Piscataway, NJ 08855 USA
[2] Siemens Corp Res, Princeton, NJ USA
[3] Univ Pennsylvania, Dept Surg Pathol, Philadelphia, PA USA
关键词
D O I
10.1109/ISBI.2010.5490238
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A single digital pathology image can occupy over 10 gigabytes of hard disk space, rendering it difficult to store, analyze, and transmit. Though image compression provides a means of reducing the storage requirement, its effects on CAD (and pathologist) performance are not yet clear. In this work we assess the impact of compression on the ability of a CAD system to detect carcinoma of the prostate (CaP) in histological sections. The CAD algorithm proceeds as follows: Glands in the tissue are segmented using a region-growing algorithm. The size of each gland is then extracted and modeled using a mixture of Gamma distributions. A Markov prior (specifically, a probabilistic pairwise Markov model) is employed to encourage nearby glands to share the same class (i.e. cancerous or non-cancerous). Finally, cancerous glands are aggregated into continuous regions using a distance-hull algorithm. We evaluate CAD performance over 12 images compressed at 14 different compression ratios using JPEG2000. Algorithm performance (measured using the under the receiver operating characteristic curves) remains relatively constant for compression ratios up to 1:256. After this point performance degrades precipitously. We also have an expert pathologist view the compressed images and assign a confidence measure as to their diagnostic fidelity.
引用
收藏
页码:1313 / 1316
页数:4
相关论文
共 50 条
  • [1] Computer aided prostate cancer diagnosis using image enhancement and JPEG2000
    Gao, M
    Bridgman, P
    Kumar, S
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXVI, 2003, 5203 : 323 - 334
  • [2] Evaluation of breast cancer with a computer-aided detection system by mammographic appearance and histopathology
    Brem, RF
    Rapelyea, JA
    Zisman, G
    Hoffmeister, JW
    DeSimio, MP
    CANCER, 2005, 104 (05) : 931 - 935
  • [3] Evaluation of the effect of JPEG and JPEG2000 image compression on the detection of diabetic retinopathy
    Conrath, J.
    Erginay, A.
    Giorgi, R.
    Lecleire-Collet, A.
    Vicaut, E.
    Klein, J-C
    Gaudric, A.
    Massin, P.
    EYE, 2007, 21 (04) : 487 - 493
  • [4] Evaluation of the effect of JPEG and JPEG2000 image compression on the detection of diabetic retinopathy
    J Conrath
    A Erginay
    R Giorgi
    A Lecleire-Collet
    E Vicaut
    J-C Klein
    A Gaudric
    P Massin
    Eye, 2007, 21 : 487 - 493
  • [5] Computer-aided detection of prostate cancer
    Llobet, Rafael
    Perez-Cortes, Juan C.
    Toselli, Alejandro H.
    Juan, Alfons
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2007, 76 (07) : 547 - 556
  • [6] Reply to ‘Evaluation of the effect of JPEG and JPEG2000 image compression on the detection of diabetic retinopathy’
    D Atan
    C Foy
    P H Scanlon
    Eye, 2008, 22 : 471 - 471
  • [7] Reply to 'Evaluation of the effect of JPEG and JPEG2000 image compression on the detection of diabetic retinopathy'
    Atan, D.
    Foy, C.
    Scanlon, P. H.
    EYE, 2008, 22 (03) : 471 - 471
  • [8] A COMPUTER-AIDED SYSTEM FOR MASS DETECTION AND CLASSIFICATION IN DIGITIZED MAMMOGRAMS
    Yang, Sheng-Chih
    Wang, Chuin-Mu
    Chung, Yi-Nung
    Hsu, Giu-Cheng
    Lee, San-Kan
    Chung, Pau-Choo
    Chang, Chein-, I
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2005, 17 (05): : 215 - 228
  • [9] Computer-Aided Detection of Prostate Cancer inMRI
    Litjens, Geert
    Debats, Oscar
    Barentsz, Jelle
    Karssemeijer, Nico
    Huisman, Henkjan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (05) : 1083 - 1092
  • [10] Breast cancer evaluation with a computer-aided detection (CAD) system by mammographic presentation, lesion size, and histopathology
    Malich, A
    Marx, C
    Facius, M
    Vogel, D
    Freesmeyer, MG
    Kaiser, WA