Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels

被引:180
作者
Setsompop, K. [1 ]
Wald, L. L. [2 ,3 ]
Alagappan, V. [2 ]
Gagoski, B. A. [1 ]
Adalsteinsson, E. [1 ,3 ]
机构
[1] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[2] Harvard Univ, Sch Med, MGH, AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[3] MIT, Harvard MIT Hlth Sci & Technol, Cambridge, MA 02139 USA
关键词
parallel excitation; acceleration; magnitude least squares; RF shimming;
D O I
10.1002/mrm.21513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spatially tailored radio frequency (RF) excitations accelerated with parallel transmit systems provide the opportunity to create shaped volume excitations or mitigate inhomogeneous B-1 excitation profiles with clinically relevant pulse lengths. While such excitations are often designed as a least-squares optimized approximation to a target magnitude and phase profile, adherence to the target phase profile is usually not important as long as the excitation phase is slowly varying compared with the voxel dimension. In this work, we demonstrate a method for a magnitude least squares optimization of the target magnetization profile for multichannel parallel excitation to improve the magnitude profile and reduce the RF power at the cost of a less uniform phase profile. The method enables the designer to trade off the allowed spatial phase variation for the improvement in magnitude profile and reduction in RF power. We validate the method with simulation studies and demonstrate its performance in fourfold accelerated two-dimensional spiral excitations, as well as for uniform in-plane slice selective parallel excitations using an eight-channel transmit array on a 7T human MRI scanner. The experimental results are in good agreement with the simulations, which show significant improvement in the magnitude profile and reductions in the required RF power while still maintaining negligible intravoxel phase variation.
引用
收藏
页码:908 / 915
页数:8
相关论文
共 22 条
  • [1] ALAGAPPAN V, 2007, P 15 ANN M ISMRM BER, P35
  • [2] Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies
    Collins, CM
    Liu, W
    Swift, BJ
    Smith, MB
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1327 - 1332
  • [3] Spatial domain method for the design of RF pulses in multicoil parallel excitation
    Grissom, William
    Yip, Chun-yu
    Zhang, Zhenghui
    Stenger, V. Andrew
    Fessler, Jeffrey A.
    Noll, Douglas C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (03) : 620 - 629
  • [4] GRISWOLD M, 2005, P 13 ANN M ISMRM MIA, P2435
  • [5] Haacke EM, 1999, MAGNETIC RESONANCE I
  • [6] Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonator
    Ibrahim, TS
    Lee, R
    Baertlein, BA
    Abduljalil, AM
    Zhu, H
    Robitaille, PML
    [J]. MAGNETIC RESONANCE IMAGING, 2001, 19 (10) : 1339 - 1347
  • [7] Kassakian PW, 2006, CONVEX APPROXIMATION
  • [8] Transmit SENSE
    Katscher, U
    Börnert, P
    Leussler, C
    van den Brink, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 144 - 150
  • [9] KATSCHER U, 2007, P JOINT ANN M ISMRM, P1693
  • [10] Kerr A., 2007, P 15 ANN M ISMRM BER, V1694