ESTABLISHING BRDF CALIBRATION CAPABILITIES THROUGH SHORTWAVE INFRARED

被引:8
作者
Georgiev, Georgi T. [1 ]
Butler, James J. [2 ]
Thome, Kurt [2 ]
Cooksey, Catherine [3 ]
Ding, Leibo [4 ]
机构
[1] NASA, Langley Res Ctr, Hampton, VA 23666 USA
[2] NASA, Goddard Space Flight Ctr, Greenbelt, MD 20771 USA
[3] NIST, Gaithersburg, MD 20899 USA
[4] Sci Syst & Applicat, Lanham, MD 20706 USA
来源
EARTH OBSERVING SYSTEMS XXII | 2017年 / 10402卷
关键词
BRDF; Calibration; RBI; JPSS; Reflectance; Remote Sensing; REFLECTANCE FACTOR;
D O I
10.1117/12.2273007
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Satellite instruments operating in the reflective solar wavelength region require accurate and precise determination of the Bidirectional Reflectance Distribution Functions (BRDFs) of the laboratory and flight diffusers used in their pre-flight and on-orbit calibrations. This paper advances that initial work and presents a comparison of spectral Bidirectional Reflectance Distribution Function (BRDF) and Directional Hemispherical Reflectance (DHR) of Spectralon*, a common material for laboratory and on-orbit flight diffusers. A new measurement setup for BRDF measurements from 900 nm to 2500 nm located at NASA Goddard Space Flight Center (GSFC) is described. The GSFC setup employs an extended indium gallium arsenide detector, bandpass filters, and a supercontinuum light source. Comparisons of the GSFC BRDF measurements in the shortwave infrared (SWIR) with those made by the National Institute of Standards and Technology (NIST) Spectral Tri-function Automated Reference Reflectometer (STARR) are presented. The Spectralon sample used in this study was 2 inch diameter, 99% white pressed and sintered Polytetrafluoroethylene (PTFE) target. The NASA/NIST BRDF comparison measurements were made at an incident angle of 0 degrees and viewing angle of 45 degrees. Additional BRDF data not compared to NIST were measured at additional incident and viewing angle geometries and are not presented here. The total combined uncertainty for the measurement of BRDF in the SWIR range made by the GSFC scatterometer is less than 1% (k = 1). This study is in support of the calibration of the Radiation Budget Instrument (RBI) and Visible Infrared Imaging Radiometer Suit (VIIRS) instruments of the Joint Polar Satellite System (JPSS) and other current and future NASA remote sensing missions operating across the reflected solar wavelength region.
引用
收藏
页数:11
相关论文
共 15 条
[1]  
[Anonymous], 1977, TECHNICAL REPORT
[2]  
Barnes P. Y., 1999, Spectral reflectance
[3]   Establishment and application of the 0/45 reflectance factor scale over the shortwave infrared [J].
Cooksey, Catherine C. ;
Allen, David W. ;
Tsai, Benjamin K. ;
Yoon, Howard W. .
APPLIED OPTICS, 2015, 54 (10) :3064-3071
[4]   Modeling of Spectralon diffusers for radiometric calibration in remote sensing [J].
Courrèges-Lacoste, GB ;
Schaarsberg, JG ;
Sprik, R ;
Delwart, S .
OPTICAL ENGINEERING, 2003, 42 (12) :3600-3607
[5]  
Early EA, 2000, J ATMOS OCEAN TECH, V17, P1077, DOI 10.1175/1520-0426(2000)017<1077:BRRRIS>2.0.CO
[6]  
2
[7]   SWIR CALIBRATION OF SPECTRALON REFLECTANCE FACTOR [J].
Georgiev, Georgi T. ;
Butler, James J. ;
Cooksey, Catherine ;
Ding, Leibo ;
Thome, Kurtis J. .
SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XV, 2011, 8176
[8]   Near infrared 45°/0° reflectance factor of pressed polytetrafluoroethylene (PTFE) powder [J].
Nadal, ME ;
Barnes, PY .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1999, 104 (02) :185-188
[9]  
NIST Measurement Services, 1998, NIST SPECIAL PUBLICA, V250-48
[10]  
SCHIFF TF, 1993, P SOC PHOTO-OPT INS, V1995, P121