A systematic approach to standardize artificial aging of resin composite cements

被引:45
作者
Blumer, Lukas [1 ]
Schmidli, Fredy [1 ]
Weiger, Roland [2 ]
Fischer, Jens [1 ,3 ]
机构
[1] Univ Basel, Univ Hosp Dent Med, Dept Dent Mat & Engn, CH-4056 Basel, Switzerland
[2] Univ Basel, Univ Hosp Dent Med, Dept Periodontol Endodontol & Cariol, CH-4056 Basel, Switzerland
[3] VITA Zahnfabrik, Bad Sackingen, Germany
关键词
Resin composite cement; Compressive strength; Indirect tensile strength; Aging; Thermal cycling; International standardization; DENTAL COMPOSITES; MECHANICAL-PROPERTIES; LUTING AGENTS; CONVERSION; WATER; TEMPERATURES; STRENGTH;
D O I
10.1016/j.dental.2015.04.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. The aim of the investigation was to contribute to the ongoing discussion at the international standardization committee on how to artificially age dental resin composite cements. Methods. Indirect tensile strength (n=30) of a dual-cured resin composite cement (Panavia F2.0) was measured to evaluate the effect of water storage at 37 degrees C or thermal cycling (5 degrees C/55 degrees C/1 mm) for up to 64 days. The influence of water temperature (5-65 degrees C) after 16 days and the effect of 1 day water storage at 37 degrees C prior to aging were assessed. Storage in air at 37 degrees C served as control. Results. Thermal cycling affected the indirect tensile strength most, followed by water storage at 55 degrees C, whereas water storage at 37 degrees C had only little influence. Major deterioration occurred before day 4 cycles). A 1-day pre-treatment by water storage at 37 degrees C prior to thermal cycling attenuated the effect of aging. Signcance. For the material investigated, thermal cycling for 4 days is the most efficient aging procedure. A 1-day water storage at 37 C prior to thermal cycling is recommended to allow complete polymerization. A 4-day water storage at 55 degrees C may be considered as a viable alternative to thermal cycling. (C) 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:855 / 863
页数:9
相关论文
共 39 条
  • [1] ABOUMADINA MM, 2008, INT J DENT SCI, V6
  • [2] Effect of storage in artificial saliva and thermal cycling on Knoop hardness of resin denture teeth
    Assuncao, Wirley Goncalves
    Gomes, Erica Alves
    Ricardo Barao, Valentim Adelino
    Barbosa, Debora Barros
    Delben, Juliana Aparecida
    Tabata, Lucas Fernando
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2010, 54 (03) : 123 - 127
  • [3] Mechanical and physical properties of contemporary dental luting agents
    Attar, N
    Tam, LE
    McComb, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 89 (02) : 127 - 134
  • [4] Intra-oral temperatures during function
    Barclay, CW
    Spence, D
    Laird, WRE
    [J]. JOURNAL OF ORAL REHABILITATION, 2005, 32 (12) : 886 - 894
  • [5] BERGMANN CP, 2013, DENT CERAMICS MICROS, P76
  • [6] Braga Pereira Sarina Maciel., 2007, Brazilian Journal Of Oral Sciences, Vol, V6, No, P1372
  • [7] Braga Roberto R, 2002, J Esthet Restor Dent, V14, P368, DOI 10.1111/j.1708-8240.2002.tb00179.x
  • [8] Mechanical properties of resin cements with different activation modes
    Braga, RR
    Cesar, PF
    Gonzaga, CC
    [J]. JOURNAL OF ORAL REHABILITATION, 2002, 29 (03) : 257 - 262
  • [9] Effect of pre-cure temperature on the bonding potential of self-etch and self-adhesive resin cements
    Cantoro, Amerigo
    Goracci, Cecilia
    Papacchini, Federica
    Mazzitelli, Claudia
    Fadda, Giovanni Maria
    Ferrari, Marco
    [J]. DENTAL MATERIALS, 2008, 24 (05) : 577 - 583
  • [10] Bonding potential of self-adhesive luting agents used at different temperatures to lute composite onlays
    Cantoro, Amerigo
    Goracci, Cecilia
    Carvalho, Carlos Augusto
    Coniglio, Ivanovic
    Ferrari, Marco
    [J]. JOURNAL OF DENTISTRY, 2009, 37 (06) : 454 - 461