Tubular column to H-beam connections without diaphragms

被引:0
|
作者
Kamba, T [1 ]
Taclendo, C [1 ]
Namba, H [1 ]
机构
[1] Osaka Inst Technol, Osaka 535, Japan
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The concentration of the study is on the elastic-plastic behavior of CHS and RHS column to wide flange beam connection performed by test and finite element analyses. It consists on the estimation of local and shear deformation (theta(L) and gamma(P)), initial stiffness K, yield load P-y and maximum load P-max with various parameters such as D/t, B-f/D and t(f)/t. Furthermore, the effect of members such beam, column and joint panel are also taken extra considerations. The summary of investigating test and numerical analyses results are shown below:(1) CHS column connections show stable behavior up to theta = 3/100, and SHS column connections show unstable behavior at theta = 3/100, (2) Initial stiffness of the local deformation of the connection subjected to horizontal load is larger than that of vertical load for CHS column connection. The effect of loading condition on initial stiffness of local deformation for SHS column connection is small, (3) FEA results follow test result with good accuracy, and (4) There is a big difference between the shear stress between inner and outer face of element at the joint panel. The inequilibrium of the shear stress is caused by the local deformation.
引用
收藏
页码:429 / 438
页数:10
相关论文
共 50 条
  • [1] Seismic Performance of Wall-Type Concrete-Filled Steel Tubular Column to H-Beam Connections with Internal Diaphragms
    Liu, Hanchao
    Lei, Honggang
    Huang, Yuqi
    Chen, Yongchang
    Xu, Feng
    BUILDINGS, 2024, 14 (06)
  • [2] Welded tubular column to H-beam connections: Three dimensional cyclic tests
    Wang, W.
    Chen, Y. Y.
    Li, W. Q.
    Chen, X.
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 457 - 463
  • [3] Development of new inner diaphragms for a H-beam and composite box column joint
    Khan, Mahbub
    Uy, Brian
    Kim, Jin W.
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (03): : 363 - 373
  • [4] Behavior of welded CFT column to H-beam connections with external stiffeners
    Shin, KJ
    Kim, YJ
    Oh, YS
    Moon, TS
    ENGINEERING STRUCTURES, 2004, 26 (13) : 1877 - 1887
  • [5] Experimental seismic behaviour of L-CFST column to H-beam connections
    Zhang, Wang
    Chen, Zhihua
    Xiong, Qingqing
    Zhou, Ting
    Rong, Xian
    Du, Yansheng
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (06): : 793 - 808
  • [6] Study on beam to box column connections with split diaphragms
    Fukuda, K
    Otake, F
    Tabuchi, M
    TUBULAR STRUCTURES VIII, 1998, : 595 - 603
  • [7] Seismic performance and design of an innovative dual vertical diaphragms joint between flat CFST column and H-beam
    Deng, En-Feng
    Wu, Shao-Tong
    Qian, Hui
    He, Jin -Ming
    Zhang, Jun-Feng
    Yu, Hong -Xia
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [8] Seismic performance test of bolted connections between precast-concrete column and H-beam
    Park, SK
    Korus 2004, Vol 2, Proceedings, 2004, : 335 - 339
  • [9] Experimental study of structural behavior of beam-to-column connections reinforced by increasing plate thickness of column without diaphragms
    Morita, K
    Ebato, K
    Furusawa, K
    Fujita, K
    Hamano, K
    TUBULAR STRUCTURES VIII, 1998, : 585 - 594
  • [10] Studies on seismic behavior of steel beam to concrete-filled steel tubular column connections with through diaphragms
    Wang, Liyao
    Zhang, Yong
    Bian, Yongfeng
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (SUPPL. 1): : 398 - 403