Variation in the outer diameter of vascular sheaths commonly used in infant cardiac catheterization

被引:5
作者
Mathis, Christopher [1 ]
Romans, Ryan [1 ]
Divekar, Abhay [1 ,2 ]
机构
[1] Childrens Mercy Hosp, Ward Family Heart Ctr, Pediat Cardiol, Kansas City, MO 64108 USA
[2] Rocky Mt Pediat Cardiol, 2055 N High St Ste 255, Denver, CO 80205 USA
关键词
catheter design; complications; congenital heart disease; pediatrics; vascular access; GLIDESHEATH SLENDER; RISK-FACTORS; FEASIBILITY; PREVALENCE; EXPERIENCE; ACCESS;
D O I
10.1002/ccd.28825
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To compare the outer diameter (OD) of conventional and radial sheaths from different manufacturers for sizes typically used in infant catheterization. Background The smallest sheath size is recommended to minimize risk of arterial injury in infants. However, sheath size refers to its internal diameter (ID), but it is the larger OD that determines risk. The OD varies between manufacturers and is frequently not known to the end user. Methods Three authors measured the OD of 3, 3.3, 4, 5, and 6 French (Fr) sheaths from different manufacturers using a Mitutoyo digital micrometer. Continuous variables are reported as mean +/- SD. The midshaft and proximal-shaft sheath measurements were compared using an independent samples t test. Agreement between author measurements was tested using intra- and inter-rater reliability analysis. Manufacturer sheath OD measurements were obtained. Statistical significance was set at p < .05. Results There was no difference in the measured sheath diameters at the midpoint and proximally (p < .05). The intra-rater and inter-rater reliability were excellent (Intraclass correlation coefficient 1.0). Among conventional sheaths the OD varied between manufacturers, Terumo sheaths had the smallest and Galt sheaths had the largest OD. Radial sheaths had the smallest OD (1 Fr smaller) when compared to similar sized conventional sheaths. For instance, the OD of 4 Fr radial sheath (1.610 +/- 0.006 mm) is essentially the same as the OD of the conventional 3 Fr (1.644 +/- 0.016 mm) and 3.3 Fr (1.635 +/- 0.005 mm) sheaths. Conclusions Our study shows variation in the OD of sheaths used in infant catheterization. The radial sheaths offer the smallest OD across sizes.
引用
收藏
页码:620 / 625
页数:6
相关论文
共 12 条
[1]   Use of 3 French catheters for diagnostic and interventional procedures in newborns and small infants [J].
Agnoletti, G ;
Boudjemline, Y ;
Largen, E ;
Aggoun, Y ;
Szezepanski, I ;
Bonnet, D ;
Sidi, D .
HEART, 2003, 89 (11) :1350-1351
[2]   Ultrasound-guided femoral arterial access in pediatric cardiac catheterizations: A prospective evaluation of the prevalence, risk factors, and mechanism for acute loss of arterial pulse [J].
Alexander, John ;
Yohannan, Thomas ;
Abutineh, Iman ;
Agrawal, Vijaykumar ;
Lloyd, Hannah ;
Zurakowski, David ;
Waller, B. Rush ;
Sathanandam, Shyam .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (07) :1098-1107
[3]   First Prospective Multicenter Experience with the 7 French Glidesheath Slender for Complex Transradial Coronary Interventions [J].
Aminian, Adel ;
Iglesias, Juan F. ;
Van Mieghem, Carlos ;
Zuffi, Andrea ;
Ferrara, Angela ;
Manih, Roukos ;
Dolatabadi, Dariouch ;
Lalmand, Jacques ;
Saito, Shigeru .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 89 (06) :1014-1020
[4]   Initial Experience with the Glidesheath Slender for Transradial Coronary Angiography and Intervention: A Feasibility Study with Prospective Radial Ultrasound Follow-Up [J].
Aminian, Adel ;
Dolatabadi, Dariouch ;
Lefebvre, Pascal ;
Zimmerman, Robert ;
Brunner, Philippe ;
Michalakis, Georges ;
Lalmand, Jacques .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (03) :436-442
[5]   Incidence and predictors of cardiac catheterisation-related arterial thrombosis in children [J].
Brotschi, Barbara ;
Hug, Maja I. ;
Kretschmar, Oliver ;
Rizzi, Mattia ;
Albisetti, Manuela .
HEART, 2015, 101 (12) :948-953
[6]  
Fleming GA, 2020, FEMORAL ARTERY INJUR
[7]  
Forbes T, 2014, 2014 SCAI ANN M MAY
[8]   Prevalence of and risk factors for acute occlusive arterial injury following pediatric cardiac catheterization: A large single-center cohort study [J].
Glatz, Andrew C. ;
Shah, Samir S. ;
McCarthy, Ann L. ;
Geisser, Diana ;
Daniels, Kaitlyn ;
Xie, Dawei ;
Hanna, Brian D. ;
Grundmeier, Robert W. ;
Gillespie, Matthew J. ;
Rome, Jonathan J. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (03) :454-462
[9]   Focus on maximal miniaturisation of transradial coronary access materials and techniques by the Slender Club Japan and Europe: an overview and classification [J].
Kiemeneij, Ferdinand ;
Yoshimachi, Fuminobo ;
Matsukage, Takashi ;
Amoroso, Giovanni ;
Fraser, Douglas ;
Claessen, Bimmer E. ;
Saito, Shigeru .
EUROINTERVENTION, 2015, 10 (10) :1178-1186
[10]  
Saito S, 1999, CATHETER CARDIO INTE, V46, P173, DOI 10.1002/(SICI)1522-726X(199902)46:2<173::AID-CCD12>3.0.CO