On the minimum size of representative volume element: An experimental investigation

被引:0
作者
Liu, C [1 ]
机构
[1] Los Alamos Natl Lab, Struct Properties Relat Mat Sci & Technol Div, Los Alamos, NM 87545 USA
关键词
heterogeneous materials; representative volume element; digital image correlation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the minimum size of the representative volume element (RVE) of a heterogeneous material is determined experimentally using the digital image correlation technique. Experiments of uniaxial compression and thermal expansion were conducted on PBS 9501, a high explosive simulant material. The minimum size of the RVE of the PBS 9501 heterogeneous material, where the average crystal diameter of the material is of the order of 100 Rm, was determined to be approximately 1.5 mm. This result is consistent with numerical calculations on polycrystalline materials and some other composites.
引用
收藏
页码:238 / 243
页数:6
相关论文
共 12 条